Outdoor Heat Pump User’ s Inf ormation and Installation Instructions T3BN Series High Effi ciency Commer cial Split System These instructions are pr imarily intended to assist qualifi ed individuals e xpe- rienced in the proper installation of heating and/or air conditioning appliances.
2 2. Set the ther mostat temper ature to the desired temperature le v el using the temperature selector . Please ref er to the separate detailed thermostat user’ s manual f or complete instructions regarding ther mostat prog ramming.
3 T O MAINT AIN Y OUR HEA T PUMP— CA UTION: Be certain the electrical power to the outdoor unit and the furnace/air handler is disconnected before doing the follo wing recommended maintenance.
4 Read Y our W arranty Please read the separate w arranty document completely . It contains v aluable inf ormation about your system. GENERAL INFORMA TION Read the f ollowing instructions completely before perf or ming the installation. Outdoor Unit Section — Each outdoor unit is shipped with a refrigerant holding charge.
5 The maximum recommended interconnecting refrigerant line length is 75 f eet, and the v er tical elev ation diff erence between the indoor and outdoor sections should not e xceed 20 f eet. Consult long line application guide for installations in e xcess of these limits.
6 Electrical P ower Wiring — Electr ical po wer wiring must comply with the current provisions of the “National Electrical Code” (ANSI/NFP A 70) and with applicable local codes ha ving jurisdiction.
7 GR W 2 CE O Y Thermostat R Air Handler Heat Pump OD Section T ypical Heat Pump with Standar d Air Handler O NO TE: Jumper between W2 and E is required when no OD T -Stat is used.
8 Indoor Blower — Set the thermostat function s witch to COOLING and the fan s witch to ON. V erify that the indoor blo wer is operating and that airfl ow is not restricted. Set the f an s witch back to A UT O . Low-Pressure Switc h — A low-pressure s witch is f actor y-installed (see attached).
9 2. Jumper the “T2”-”DFT” test pins. This will indicate to the board that the defrost T -stat is closed(if the compressor is running). Defrost T -stat is closed at 32° or below and is open at 68° or abov e. But it’ s state is unknown if the temper ature is between 32°F and 68°F .
10 Refrigerant Charging Charts 7.5 Ton HP TXV Charging Chart 150 175 200 225 250 275 300 325 350 375 400 75 80 85 90 95 100 105 110 115 120 125 130 135 Liquid Temperature (F) Liquid Pressure (psig) Ad.
11 Refrigerant Charging Charts 10 Ton HP TXV Charging Chart 150 175 200 225 250 275 300 325 350 375 400 75 80 85 90 95 100 105 110 115 120 125 130 135 Liquid Temperature (F) Liquid Pressure (psig) Add.
12 REFRIGERANT CHARGING CHAR T Heating Mode of Operation PR OCEDURE FOR CHARGING 10-T ON HEA T PUMP IN HEA TING MODE. 1. Ev acuate the refr igerant system. 2. Charge the system by w eighing in 30 lbs R-22 refrigerant. This is the recommended charge for 5/8 inch 15 f oot line set.
13 RELA Y 4 2 3 1 6 5 T1 T2 T3 CCH C S R T1 T2 C Y O W2 R DFT DF1 DF2 E DEFROST CONTROL BOARD CY O W 2 R E L3 L2 L1 GRD REV VA LVE DFT LOW PRESSURE SWITCH THREE PHASE FIELD SUPPL Y CAP ACITOR CONT ACT.
14 A CCESSORIES — Condensing Unit Low Ambient Kit 913549A- Maintains system pressures during low ambient conditions. PHYSICAL AND ELECTRICAL SPECIFICA TIONS / OUTDOOR UNITS 10.
15.
INST ALLER: PLEASE LEA VE THESE INST ALLA TION INSTRUCTIONS WITH THE HOMEO WNER ¢708538G¤ 708538A 708538A (replaces 7085380) Specifi cations and illustr ations subject to change without notice and without incurring obligations.
デバイスNordyne T3BNの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Nordyne T3BNをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNordyne T3BNの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Nordyne T3BNの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Nordyne T3BNで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Nordyne T3BNを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNordyne T3BNの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Nordyne T3BNに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNordyne T3BNデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。