Nortel NetworksメーカーV100の使用説明書/サービス説明書
ページ先へ移動 of 176
NN10364-301 Multimedia Communication Portfolio Multimedia Communication Server 2-server Sun Fire V100 Solari s Installation and Commissioning Guide MCS 5100 3.
.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 3 Copyright © 20 06 Nortel Networks Contents Finding the latest updates on the Nortel We b site . . . . . . . . . . . . . . . . . . . . 7 How to get help . . . . . . . . . . . .
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 4 Copyright © 20 06 Nortel Networks Installing Disk 6 (MgmtSvr/AcctMgr only) . . . . . . . . . . . . . . . . . . . . . . . . . 67 Installing Oracle 9.2.0.4 on t he database server . . . . . . . . . .
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 5 Copyright © 20 06 Nortel Networks Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127 Adding and configuring the Web Client Manager .
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 6 Copyright © 20 06 Nortel Networks.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e Copyright © 20 06 Nortel Networks Finding the latest updates on the Nor tel W eb site The content of this document ation was current at the time the product was released.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 8 Copyright © 20 06 Nortel Networks.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e Copyright © 20 06 Nortel Networks Ho w to g et help This section explains ho w to get he lp for Nortel products and services.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 10 Copyright © 20 06 Nortel Networks Getting help from a specialist by using an Express Routing Code T o access some Nortel T echnical Solutions Centers, you can use an Express Routing Code (ERC) to quickly route your call to a specialist in your Nortel product or service.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e Copyright © 20 06 Nortel Networks Over vie w The MCS 2-ser v er Sun Fi re* V100 Solar is system is a small-scale v ersion of the Multimedia Comm unication P or tfolio (MCP) system, geared tow ards an environm ent with a maximum of 250 subscribers.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 12 Copyright © 20 06 Nortel Networks Figure 2 2-server network w ith single Ethernet switch Figure 3 2-ser ver netw ork MAS Ad hoc aud io conferencing with single Ethernet sw itch The rest of this document will ref er to the example data in the figure that f ollows.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 13 Copyright © 20 06 Nortel Networks Figure 4 Example of 2-server Sun Fire V100 Solaris system configuration Restrictions and limitations The 2-ser v er V100 Solar is system is non-redundant.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 14 Copyright © 20 06 Nortel Networks MCS 5100 documentation Ref er to the MCS 5100 Networ k Deplo yment and Engineering Guide, NN10313-191, that accompanies the MC S 5100 product and to your customer-specific inf or mation (CSI) datasheet fo r y our system requirements.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 15 Copyright © 20 06 Nortel Networks • MCS 5100 F ault Management: Alarm and Log reference , NN10385-900 • MCS 5100 P erf.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 16 Copyright © 20 06 Nortel Networks.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e Copyright © 20 06 Nortel Networks Bef ore y ou star t the installation Prerequisites Ha ve a vailab le your completed Cu stomer-Specific In formation (CSI) datasheet.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 18 Copyright © 20 06 Nortel Networks The procedures in this Guide assume that you are using the PuTTY VT100 ter minal emulator tool.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 19 Copyright © 20 06 Nortel Networks Ke y str oke symbols The f ollowing k ey strok e symbols are used in this document.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 20 Copyright © 20 06 Nortel Networks Server configuration The f ollowing tab le shows the basic c onfiguration of the 2-server V100 Solaris system.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 21 Copyright © 20 06 Nortel Networks MCS Base Platf or m System Softwa re disks are loaded on the f ollo wing ser v ers as in.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 22 Copyright © 20 06 Nortel Networks.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e Copyright © 20 06 Nortel Networks Minim um and recommended requirements f or customer -pr o vided PC Configure your management pc to ha v e an IP address that is in the same subnet of the IP address range used f or y our ser vers .
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 24 Copyright © 20 06 Nortel Networks • mouse: required • Video Graphics Card: — minimum: 640x480 @8bpp [256 colors] V G A — recommended: 80.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e Copyright © 20 06 Nortel Networks Setting up the baseline har d ware Baseline har dware See the f ollowing figure f or an ov er view of the hardw are connectivity . Figure 3 Hard ware connections overview A TTENTION Y ou need an uninterr upt ed po wer source (UPS).
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 26 Copyright © 20 06 Nortel Networks Hardware required f or the 2-server system consists of the f ollowing: • terminal ser ver : 1 MR V LX-4008-101AC including — Linux-based secure consol e standalone unit with 8 RS232 RJ45 por ts — inter nal V .
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 27 Copyright © 20 06 Nortel Networks • Media Application Ser v er : 1 IBM x336 (2 3.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 28 Copyright © 20 06 Nortel Networks Figure 4 MCS 5100 19-inch rac k Connecting the Sun Fire V100 server to the lay er-2 s witch Procedure 2 Connec.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 29 Copyright © 20 06 Nortel Networks Figure 6 Sun Fire V100 server cabling to la yer-2 s witch Note 1: Net 0 and Net 1 are f or redun dancy . It is pref erab le that each Ether net por t get cabled to a diff erent la yer-2 s witch, if av ailab le, f or maximum redundancy .
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 30 Copyright © 20 06 Nortel Networks Figure 7 Sun Fire V100 server network callouts Note 1: The cables with par t numbers A0500465 or NTVW01IM are serial cables. Note 2: The P1 end goes to the V100 ser ver and the P2 end goes to the MR V LX ter minal ser ver .
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 31 Copyright © 20 06 Nortel Networks Figure 8 P1 and P2 custom cable connections to terminal server See note Note : This cabl e is only connected to configure the terminal ser v er .
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 32 Copyright © 20 06 Nortel Networks.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e Copyright © 20 06 Nortel Networks Installing and accessing the MR V LX-4000 series terminal ser ver The MR V LX terminal ser ver allows the installer to access all the ser v ers simultaneously .
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 34 Copyright © 20 06 Nortel Networks Figure 9 MR V Configur ation Console windo w 2 Mak e sure you ha ve the J av a Plug-in installed. 3 When your bro wser connects to the terminal ser ver , the Ja va Security W ar ning window appears .
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 35 Copyright © 20 06 Nortel Networks 4 Click on Grant this session . The J av a Security W ar ning window closes. The LX Series Configuration Console page reappears , now with the green cons ole selection visib le.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 36 Copyright © 20 06 Nortel Networks Figure 12 Login window 6 Enter your Username and P ass word, and clic k Login . Note: By def ault, authentication is done against the local user database. T o star t, us e the known username InReach and pass word access .
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 37 Copyright © 20 06 Nortel Networks Figure 13 User login window 8 T o log in as a superuser , click the Admin b utton on the tool bar and log in with the def ault Super u ser pass word system.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 38 Copyright © 20 06 Nortel Networks Figure 14 Example: selecting P orts: Async a When you clic k on a por t, the fo llo wing dialog box appears f or you to enter y our inf or mation.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 39 Copyright © 20 06 Nortel Networks Figure 15 P or t 19 dialog bo x F or details on using the IP Conf iguration Menu, ref e r to “Using the IP Configuration Men u” in the LX-Series Configuration Guide.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 40 Copyright © 20 06 Nortel Networks Procedure 6 Connecting thr ough the server to the MR V LX terminal server At the mana gement pc, 1 Use the f o.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 41 Copyright © 20 06 Nortel Networks 4 Enter a ne w user passw ord at the Enter your NEW password: prompt. The pass word will be displa yed as asterisks. 5 Re-enter the new user passw ord at the Re-Enter your NEW password: prompt.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 42 Copyright © 20 06 Nortel Networks 7 Enter your pass w ord: system [Enter] 8 Define ser v er ip address <IP address of the terminal ser ver>.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 43 Copyright © 20 06 Nortel Networks 4 F or por t, enter <the por t number which corresponds to A/LOM (Serial A) on the V100 and t he MR V LX ter minal ser v er>. Note 1: F or LOM por ts , use ter minal ser ver por ts 2100-2400 (ph ysical por ts 1-4).
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 44 Copyright © 20 06 Nortel Networks.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e Copyright © 20 06 Nortel Networks P owering on the server s Procedure 10 P owering on the servers At the server , 1 T ur n po wer on to the ser v er . 2 If the system boots up , l og into the ser v er as root .
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 46 Copyright © 20 06 Nortel Networks 4 The >ok prompt appears. A TTENTION If you do not use PuTTY , use t he appropriate ke y sequence to send a break to the ser v er to get an >ok prompt.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e Copyright © 20 06 Nortel Networks Installing Disks 1 to 3 Installing CD1 Appro ximate time estimate = 45 minutes Procedure 12 Installing CD1 At the mana gement pc, 1 Place CD1 in the CD-R OM dr iv e.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 48 Copyright © 20 06 Nortel Networks 2 At the >ok prompt, boot the system: boot cdrom - install [Enter] Note 1: F or instr uctions on how to get to the >ok prompt, see P owering on the ser vers on page 45 .
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 49 Copyright © 20 06 Nortel Networks Netw ork Connectivity/Networked 3 Accept the def ault Yes by pressing Esc+2 to contin ue. DHCP/Use DHCP 4 Accept the def ault No by pressing Esc+2 to continue .
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 50 Copyright © 20 06 Nortel Networks Netmask/Netmask 9 Enter the subnet mask, f or e xample: 255.255.255.0 . Press Esc+2 to continue . IPv6/Enables IPv6 10 Accept the def ault No . Press Esc+2 to continue .
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 51 Copyright © 20 06 Nortel Networks Continuing the pr ocess 15 Confir m y our information. Ensure all fields are filled correctly . Press Esc+2 to continue . Press Esc+4 if y ou need to change anything.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 52 Copyright © 20 06 Nortel Networks 21 Y ou will see the f ollowing message: ********************************************* Choose Application conf.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 53 Copyright © 20 06 Nortel Networks Procedure 13 Installing CD2 At the mana gement pc, 1 Place CD2 in the CD-R OM dr ive and press Enter . Y ou will see a number of messages requiring no specific ans wer .
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 54 Copyright © 20 06 Nortel Networks Procedure 14 Installing CD3 At the mana gement pc, 1 Place CD3 in the CD- ROM drive and press Enter at the prompt. The installation will continue . Please wait. The system will prompt y ou for the ne xt step .
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e Copyright © 20 06 Nortel Networks Installing Disk 4 Database/Accounting/Manag emen t server (DBSvr , AcctMgr , MgmtSvr) Appro ximate time estimate = 30 minutes Procedure 15 Installing CD4 At the mana gement pc, 1 Place CD4 in the CD-R OM dr iv e and press Enter to continue.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 56 Copyright © 20 06 Nortel Networks to use the local system clock as the time source. Note: Select Time Source • X - External Clock Device • E.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 57 Copyright © 20 06 Nortel Networks 7 Press Enter to continue . 8 Y ou will see the f o llowing statement: ”You are now configuring IPMP (Multipathing)" ”Please have the Database Server Physical IP addresses and the Machine Logical IP address ready.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 58 Copyright © 20 06 Nortel Networks Enter ping target #1: 120.120.13.25 Enter ping target #2: 120.120.13.1 Enter ping target #3: 0.0.0.0 Note: Do NO T use this ser v er's own IP address as a ping target.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 59 Copyright © 20 06 Nortel Networks Y ou will see the f ollowing message: Obtaining IP Addresses for SysMgr/AcctMgr Failover.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 60 Copyright © 20 06 Nortel Networks Procedure 16 Installing CD4 At the mana gement pc, 1 Place CD4 in the CD-R OM dr iv e and press Enter to continue. W AIT until y ou see the f o llowing statement appear : ”You are now configuring the NTP time source for this server.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 61 Copyright © 20 06 Nortel Networks 9 Enter the primar y machine physi cal IP address for the dmf e0 interf ace: <Physical IP address of the dmfe0 interface> Example: 120.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 62 Copyright © 20 06 Nortel Networks Figure 17 Application server IP MP configuration summar y Is this IPMP group configuration acceptable? (Y/N) Select Y to accept or N to change. 14 The def ault route IP address shoul d appear .
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e Copyright © 20 06 Nortel Networks Installing Disk 5 (all ser ver s) Appro ximate time estimate is 30 minutes. Procedure 17 Installing CD5 At the mana gement pc, 1 Place CD5 in the CD -ROM driv e, on the ser v er , and press Enter at the prompt.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 64 Copyright © 20 06 Nortel Networks.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e Copyright © 20 06 Nortel Networks Enab ling or disabling the automatic mount Use the f ollowing pr ocedure if y ou need to use the CD-ROM auto-mount after installation of CD 5.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 66 Copyright © 20 06 Nortel Networks.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e Copyright © 20 06 Nortel Networks Installing Disk 6 (MgmtSvr/AcctMgr onl y) Appro ximate time estimate = 30 minutes Procedure 19 Installing CD 6 At the mana gement pc, 1 Place CD6 in the CD-ROM driv e, on the ser v er , and press Enter at the prompt.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 68 Copyright © 20 06 Nortel Networks.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e Copyright © 20 06 Nortel Networks Installing Orac le 9.2.0.4 on the database ser ver The procedures to install Oracle 9 on the DBSvr include storing Oracle 9 CDs 1-6 to your local hard driv e.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 70 Copyright © 20 06 Nortel Networks 5 cp [ space] Install_CD_ to_Disk [ space] / [Enter] 6 cd [ space] / [Enter] 7 .
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 71 Copyright © 20 06 Nortel Networks Ref er to this table when en tering the f ollowing command: cd [space] /IMS /ora_cds/Disk1 [Enter] ./Oracle_Install PRIMAR Y <primarydb-hostname> [space] <secondarydb-hostname>[space] | [space] tee [space] /tmp/oracleinstall.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 72 Copyright © 20 06 Nortel Networks F ailing to ans wer Y will cause the system to raise a disk space alar m on the SysMgr screen f or the DBSvr . Y ou will see the message: Removing Disk 1, Disk2, Disk3, Disk4, Disk5, Disk6 from /IMS/ora_cds.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e Copyright © 20 06 Nortel Networks Deplo ying the initial database load Prerequisites Ensure that the MCS Base Platf or m Software and Orac le 9i ha ve been installed on dat abase ser v ers.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 74 Copyright © 20 06 Nortel Networks 5 Y ou will see the f ollowing message: Select the Type of Deployment: [1] Initial Deployment [2] Upgrade of Database [3] Rollback of Database [4] Install Files only to Select 1 f or initial depl oyment, then press Enter .
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e Copyright © 20 06 Nortel Networks Deplo ying and star ting the Sysmgr Prerequisites The dbdeplo y .pl script is succe ssfully deploy ed on the database. Deplo y the Sysmgr f or a non-redu ndant configuratio n.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 76 Copyright © 20 06 Nortel Networks 3 Please enter the correct number of the load to deploy: Example [@micromgmt]/export/home/nortel:=> mgmtdeploy.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 77 Copyright © 20 06 Nortel Networks Example: 120.120.13.22 7 Will a Motorola SAM16 server (SIP PriGwy or SIP Audio Svr) be deployed? [Y/N] Alwa ys ans wer N [Enter] ev en if y ou hav e a third-par ty gate wa y .
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 78 Copyright © 20 06 Nortel Networks.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e Copyright © 20 06 Nortel Networks Registering y our license ke y Bef ore installing the lic ense ke y as descr ibed in Procedure 25, Installing the System Management Console , f ollow the procedure below to gener ate and regi ster your license ke y .
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 80 Copyright © 20 06 Nortel Networks Figure 18 KRS login screen 4 In step 1 (Location) select a login ser v er that matches your region, f or e xample, European Lo gin or Nor th Am erican Login.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 81 Copyright © 20 06 Nortel Networks Figure 19 Ke ycode Retriev al S ystem, Creating y our site 7 Select Create to register a new system.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 82 Copyright © 20 06 Nortel Networks Figure 20 Ke ycode Retriev al System, Entering your site inf ormation 8 Fill in the requested inf or mation and press the Contin ue button. Ensure you choose the correct software v ersio n from the dropdown bo x.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 83 Copyright © 20 06 Nortel Networks Figure 21 Ke ycode Retriev al System, Current Summary 9 Select the ser v er you want to ent er MA C addresses f or first, then click on Create .
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 84 Copyright © 20 06 Nortel Networks Figure 22 Ke ycode Retriev al System, Adding MA C address 11 Repeat Step 10 f or the second MA C addre ss (required). If you mak e an error , you can remo ve one or both and begi n again.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 85 Copyright © 20 06 Nortel Networks Ser v er Ser vice Guide applicable to y our system (see the Ov er view chapter f or a list ing of the ser vice guides).
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 86 Copyright © 20 06 Nortel Networks Figure 24 Ke ycode Retriev al System, Current Summary 15 T o generate k eycodes f or this site , click on Gen KC with A uth Code from the side bar , as sh o wn in the follo wing figure.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 87 Copyright © 20 06 Nortel Networks Figure 25 Ke ycode Retriev al Syst em, Gen KC with A uth Code 16 T o generate y our ke ycodes, enter one of the MAC addresses of the ser v er you w ant your A uth c ode applied to .
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 88 Copyright © 20 06 Nortel Networks Figure 26 Ke ycode Retriev al System, Finding the keycode 18 Select the proper Software V ers ion for y our system.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 89 Copyright © 20 06 Nortel Networks Figure 27 Ke ycode Retriev al S ystem, Adding a MA C ad dress 19 Enter the authcode number f or th e f eature you wish to enab le into the A uth Code box.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 90 Copyright © 20 06 Nortel Networks Figure 28 Ke ycode Retriev al S ystem, Entering the authcode 20 Select Add to hav e the KRS ac cept the authcode. 21 The KRS will v alidate the authco de and ensure the f eatures represented are v alid for y our ser ver type (CORE or MAS).
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 91 Copyright © 20 06 Nortel Networks Figure 29 Ke ycode Retriev al System, Summary of features 23 The KRS will indicate it is generating y our ke ycodes and saving the results in its database.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 92 Copyright © 20 06 Nortel Networks Figure 30 Ke ycode Retriev al S ystem, Retrieving the ke ycode The screens show the f eatures of your k e ycode and the option to download the k eycode to y our local PC .
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 93 Copyright © 20 06 Nortel Networks Figure 31 Ke ycode Retriev al System , Retrieving y our keycode, part 2 24 Download the ne w license ke y f ile to the Mg mt Svr hard drive .
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 94 Copyright © 20 06 Nortel Networks.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e Copyright © 20 06 Nortel Networks Installing and launc hing the System Management Console Prerequisites Make sure that • The dbdeploy.pl script has been successfully ex ecuted.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 96 Copyright © 20 06 Nortel Networks 12 Click Next to begin installation. 13 At the pop-up window that sa ys , Installation successfully completed , click OK .
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 97 Copyright © 20 06 Nortel Networks the License Key->Update dropdo wn menu (Y ou can also select the System=>License Ke y=>Update menu option from the System tree.) as sho wn in Figure 32, Management Console Update License K ey .
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 98 Copyright © 20 06 Nortel Networks Figure 33 Select License key File Windo w 7 Once you ha v e enter ed the new License K e y , you will see a dialog bo x notifying you whether the update is successful or f ails.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 99 Copyright © 20 06 Nortel Networks The console screen has the basic l ook and f eel of a Windows Explorer window with a tree structure on t he left, and a general inf or mation area on the r ight.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 100 Copyright © 20 06 Nortel Networks.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e Copyright © 20 06 Nortel Networks Adding a server Prerequisites The System Management C onsole has been successfully installed and star ted. Adding a server Use this procedure to ad d each of your ser v ers.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 102 Copyright © 20 06 Nortel Networks 5 Click Apply . Longitude Optional field. De scribes the longitudinal coordinates of the location of this server. default Platform type Drop-down menu with following choices: Sun or Linux.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e Copyright © 20 06 Nortel Networks Adding and configuring the Accounting Module Prerequisites Make sure that • The System Management Console has been successfully installed and star ted.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 104 Copyright © 20 06 Nortel Networks Procedure 29 Configuring the tabs At the System M anagement Console, 1 Use the v alues from the table that f ollows to complete the Central Accounting Manager tab parameters .
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 105 Copyright © 20 06 Nortel Networks 2 Click Apply . The component will deplo y . W ait until you see the dialog bo x indicating successful installati on. The component will appear in the file tree.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 106 Copyright © 20 06 Nortel Networks.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e Copyright © 20 06 Nortel Networks Adding and configuring the SIP Application Module Prerequisites Make sure that • The System Management Console has been successfully installed and star ted.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 108 Copyright © 20 06 Nortel Networks Procedure 31 Configuring the SI P Application Module tabs At the System M anagement Console, 1 Use the v alues from the follo wing table to enter into the A uthentication tab parameters .
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 109 Copyright © 20 06 Nortel Networks 2 Use the f ollowing v alues to complete the Local Accounting Manager tab . The shaded rows indicate v alues that must be addressed b y the installer .
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 110 Copyright © 20 06 Nortel Networks 3 Use the v alues from the table that f ollows to complete the Media P or tal tab parameters . The shaded rows indicate v alues that must be addressed b y the installer .
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 111 Copyright © 20 06 Nortel Networks The shaded rows indicate v alues that must be addressed b y the installer . 6 Use the v alues from the table t hat f ollows to complete the SIP TCF Base tab parameters .
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 112 Copyright © 20 06 Nortel Networks 8 Use the v alues from the table that f ollows to complete the Location Ser vice M anager tab parameters . Note: This tab applies to DNS ser v ers only . 9 Use the v alues from the table that f ollows to complete the Registrar Service tab parameters.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 113 Copyright © 20 06 Nortel Networks 10 Use the v alues from the table that f ollows to complete the Server Subscription tab parameters. 11 Use the v alues from the table that f ollows to complete the Subscription Processing tab parameters.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 114 Copyright © 20 06 Nortel Networks 14 Use the v alues from t he follo wing table to ent er into the Ov erload Controls tab parameters . Service Parameter: Label Private_Service_Address not applicable default Value: <leave blank> default Service Parameter: Label CallPark.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 115 Copyright © 20 06 Nortel Networks 15 Use the table that f ollo ws to m odify the fields for the T ranspor t Management tab . The shaded rows indicate v alues that must be addressed b y the installer .
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 116 Copyright © 20 06 Nortel Networks Remote Server Address <machine logical IP of other application server> Only fill PUBLIC Service Address field. 120.120. 13.25 Local Server Address Public_Static_Address default Parameters: NSD Number 1 default NSD Enabled unchecked Box unchecked.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 117 Copyright © 20 06 Nortel Networks 16 Click Apply . The component will deplo y . W ait until you see the dialog bo x indicating successful installati on. The component will appear in the file tree.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 118 Copyright © 20 06 Nortel Networks.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e Copyright © 20 06 Nortel Networks Adding and configuring the IP Client Manager Prerequisites Make sure that • The System Management Console has been successfully installed and star ted.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 120 Copyright © 20 06 Nortel Networks Procedure 33 Configuring the IP Client Manager tabs At the System M anagement Console, 1 Use the v alues from the table t hat f ollows to complete the IP Client Manager tab parameters .
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 121 Copyright © 20 06 Nortel Networks 2 Use the v alues from the table that f ollows to complete the Database Base tab parameters . The shaded rows indicate v alues that must be addressed b y the installer .
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 122 Copyright © 20 06 Nortel Networks The shaded rows indicate v alues that must be addressed b y the installer . 4 Use the v alues from the table t hat f ollows to complete the SIP TCF Base tab parameters .
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 123 Copyright © 20 06 Nortel Networks 6 Use the v alues from the follo wing table to enter into the In Memor y Database tab parameters. The shaded rows indicate v alues that must be addressed b y the installer .
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 124 Copyright © 20 06 Nortel Networks.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e Copyright © 20 06 Nortel Networks Installing the UFTP BaseSoftware Y ou will be installing t he UFTP software on th e application ser v er . Prerequisites The System Management C onsole has been successfully installed and star ted.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 126 Copyright © 20 06 Nortel Networks.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e Copyright © 20 06 Nortel Networks Configuring the Pr o visioning Module Prerequisites Mak e sure the System Management Console has been installed and star ted.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 128 Copyright © 20 06 Nortel Networks Procedure 36 Configuring the Pr o v isioning Module tabs At the System M anagement Console, 1 Use the v alues from the table t hat f ollows to complete the SIP TCF Base tab parameters .
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 129 Copyright © 20 06 Nortel Networks 3 Use the v alues from the table t hat f ollows to complete the W eb Client Manager tab parameters . The shaded rows indicate v alues that must be addressed b y the installer .
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 130 Copyright © 20 06 Nortel Networks 4 Use the v alues from the table that f ollows to complete the Database Base tab parameters . The shaded rows indicate v alues that must be addressed b y the installer .
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 131 Copyright © 20 06 Nortel Networks The shaded rows indicate v alues that must be addressed b y the installer . 7 Use the v alues from the table that f ollows to complete the Conf erence_Ser vice tab parameters.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 132 Copyright © 20 06 Nortel Networks.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e Copyright © 20 06 Nortel Networks Adding and configuring the W eb Client Manager Prerequisites Make sure that • The System Management Console has been successfully installed and star ted.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 134 Copyright © 20 06 Nortel Networks Procedure 38 Configuring the Web Client Manager tabs At the System M anagement Console, 1 Use the v alues from t he table that f ollows to complete the User Agent Ser v er tab parameters.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 135 Copyright © 20 06 Nortel Networks The shaded rows indicate v alues that must be addressed b y the installer . 3 Use the v alues from the table t hat f ollows to complete the W eb Client Manager tab parameters .
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 136 Copyright © 20 06 Nortel Networks 4 Use the v alues from the table that f ollows to complete the Conf erence_Ser vice tab parameters. The shaded rows indicate v alues that must be addressed b y the installer .
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 137 Copyright © 20 06 Nortel Networks The shaded rows indicate v alues that must be addressed b y the installer . 6 Click Apply . 7 The component will deplo y . W ait until you see the dialog bo x indicating successful installati on.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 138 Copyright © 20 06 Nortel Networks.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e Copyright © 20 06 Nortel Networks Installing and configuring the Orac le Monitor Prerequisites Make sure the f ollowing ar e completed successfully: • The System Management Console has been in stalled and star ted.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 140 Copyright © 20 06 Nortel Networks Procedure 40 Configuring th e Orac le Monitor tabs At the System M anagement Console, 1 Use the v alues from the table that f ollows to complete the Oracle Ser v er tab parameters.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 141 Copyright © 20 06 Nortel Networks The shaded rows indicate v alues that must be addressed b y the installer .
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 142 Copyright © 20 06 Nortel Networks Gauged Component Monitoring: Threshold monitors: Positive going threshold value 1 70 default Gauged Component.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 143 Copyright © 20 06 Nortel Networks Gauged Component Monitoring: Threshold monitors: Alarm Severity on Positive Going Thres.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 144 Copyright © 20 06 Nortel Networks 3 Use the v alues from the table that f ollows to complete the Database Base tab parameters . The shaded rows indicate v alues that must be addressed b y the installer .
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 145 Copyright © 20 06 Nortel Networks The shaded rows indicate v alues that must be addressed b y the installer . 4 Click Apply . The component will deplo y . W ait until you see the dialog bo x indicating successful installati on.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 146 Copyright © 20 06 Nortel Networks.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e Copyright © 20 06 Nortel Networks Installing the iPlanet Monitor Prerequisites Mak e sure the System Management Console has been successfully installed and star ted.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 148 Copyright © 20 06 Nortel Networks Procedure 42 Configuring the iPlanet Monitor At the System M anagement Console, 1 Use the v alues from the table t hat f ollows to complete the W eb Monitor tab parameters.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 149 Copyright © 20 06 Nortel Networks Component Monitoring: Threshold monitors: Lower Limit 0 default Component Monitoring: T.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 150 Copyright © 20 06 Nortel Networks Component Monitoring: Threshold monitors: Alarm Severity on Negative goi ng threshold NONE default Component .
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 151 Copyright © 20 06 Nortel Networks Component Monitoring: Threshold monitors: Negative goi ng threshold value 10 default Co.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 152 Copyright © 20 06 Nortel Networks Threshold monitors: Alarm Severity on Positive going threshold 1 WARNING default Threshold monitors: Alarm Se.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 153 Copyright © 20 06 Nortel Networks Component Monitoring: Positive going threshold value 1 70 default Component Monitoring:.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 154 Copyright © 20 06 Nortel Networks Component Monitoring: Component name Cpu Util default Component Monitoring: Polling interv al in minutes 1 de.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 155 Copyright © 20 06 Nortel Networks Component Monitoring: Threshold monitors: Positive going threshold hysteresis 2 5 defau.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 156 Copyright © 20 06 Nortel Networks Component Monitoring: Threshold monitors: Usage state affected unchecked default Component Monitoring: Class name com.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 157 Copyright © 20 06 Nortel Networks Component Monitoring: Threshold monitors: Positive going threshold hysteresis 1 5 defau.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 158 Copyright © 20 06 Nortel Networks Component Monitoring: Threshold monitors: Alarm Severity on Upper Limit OverRun MAJOR default Component Monit.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 159 Copyright © 20 06 Nortel Networks 2 Click Apply . W ait f or the component to appear in ser ver list. The iPlanet Monitor is installed on the same ser v er as the Provisioning Module.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 160 Copyright © 20 06 Nortel Networks.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e Copyright © 20 06 Nortel Networks V erification pr ocedures V erifying Ser ver1 (DBSvr/MgmtSvr/AcctMgr) The f ollowing commands ar e e x ecuted on the database/management/account ing Sun Fire V100 se r v er using PuTTY SSH into the machine logical IP address.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 162 Copyright © 20 06 Nortel Networks interf ace is ‘UP . ’ This exampl e output sho ws that dmf e0 is assigned to IP address 120.120. 13.20, its subnet mask is ffffff00, which translates to 255.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 163 Copyright © 20 06 Nortel Networks 120.120.13.1 The only address in this file defi nes your def ault gatew ay route (your router). If this file is empty and the mach ine is rebooted, then you will no t ha ve netw or k access to your other servers .
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 164 Copyright © 20 06 Nortel Networks 4 Look f or the entr y that star ts with ‘dmf e1. ’ The parameters that f ollow show the IP address , subnet mask, and whether the interf ace is ‘UP . ’ This exampl e output sho ws that dmf e1 is assigned to IP address 120.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 165 Copyright © 20 06 Nortel Networks The only address in this file defi nes your def ault gatew ay route (your router). If this file is empty and the mach ine is rebooted, then you will no t ha ve netw or k access to your other servers .
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 166 Copyright © 20 06 Nortel Networks.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e Copyright © 20 06 Nortel Networks Appendix A Deplo ying the PC Client Along with the initial load, Nor tel Networks delivers the f ollo wing: • Ja v a Network Launch Protocol (JNLP) file: pcclient.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 168 Copyright © 20 06 Nortel Networks.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e Copyright © 20 06 Nortel Networks Appendix B Reloading IP addresses after system installation This process prompts you f or the hostname , count r y , time-zone , and IP address to enable mo v ement of the syst em after the system is installed.
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 170 Copyright © 20 06 Nortel Networks the ser v er , which takes about fiv e minutes, and then reload the IP addresses (see Procedure 46, Reloading IP addresses after system installation ). Reloading the IP addresses on each ser v er takes about 15 minutes.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 171 Copyright © 20 06 Nortel Networks Type the number of your choice and press Return: Select 2 and press Enter .
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 172 Copyright © 20 06 Nortel Networks 9 F ollow the instructions f or inst alling Disk 4 in this document.
MCS 2-server Sun Fir e V100 Solaris Installation and Commissioning Guid e 173 Copyright © 20 06 Nortel Networks b Then log in to the Accounting ser v er and type in the f ollowing command: #/usr/local/bin/Inter face .
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006 174 Copyright © 20 06 Nortel Networks.
.
Multimedia Commun ication Portfolio Multimedia Communication Server 2-server Sun Fire V100 Solaris Installation and Commissioning Guide Copyright © 2006 Nortel Networks. All right s re served. The information in this document is subject to change without notice.
デバイスNortel Networks V100の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Nortel Networks V100をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNortel Networks V100の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Nortel Networks V100の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Nortel Networks V100で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Nortel Networks V100を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNortel Networks V100の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Nortel Networks V100に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNortel Networks V100デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。