ページ先へ移動 of 19
E SERIES NV-E6MS/NV-E6XS MUL TI-SOURCE/ MUL TI-ZONE AUDIO DISTRIBUTION SYSTEM OWNERS MANUAL VOL VOL TUN3 TUN2 TUN1 SA T CD2 CD1 MUTE ONOFF ALL OFF.
THIS APP ARA TUS SHALL NOT BE EXPOSED TO DRIPPING OR SPLASHING. NO OBJECTS FILLED WITH LIQUIDS (SUCH AS V ASES) SHALL BE PLACED ON THE APP ARA TUS. SOUND LEVEL db FLOW RESPONSE 90 93 95 97 100 103 DURA TION PER DA Y IN HOURS 8 6 4 3 2 1 CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE CHASSIS.
Congratulations on your purchase of the NUVO E Series audio distribution system. The E Series of fers the newest in multi-zone/multi-source audio technology in an attractive, easy-to-install, and simple-to-use package. The E Series system is designed for the home owner .
2 3 1 Page 2 The amplifier is designed to be turned on and remain on. The power button supplies power to the system. Each zone can then be turned on or off independently . This blue LED (light-emitting diode) will remain lit as long as the power button is engaged.
LINE OUT L LINE OUT / SPEAKER LINE OUT LINE OUT LINE OUT LINE OUT LINE OUT ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 20W/8 OHM X2 20W/8 OHM X2 20W/8 OHM X2 20W/8 OHM X2 20W/8 OHM X2 20W/8 OHM X2 RL RL.
VOL VOL TUN3 TUN2 TUN1 SA T CD2 CD1 MUTE ONOFF ALL OFF Page 4 The E Series keypad comes with four molded, replaceable covers in white, ivory , almond, and black. The selected source button remains a backlit green until a new source is selected or the zone is turned off.
OFF ON AM FM MON ST _ + _ + MUTE ON-OFF ALL OFF MEM 0 NUM 89 7 56 4 23 1 TUNER 1 TUNER 2 TUNER 3 TUNER MUL TI-ROOM Power Tune Preset VOL VOL TUNER MUL TI ROOM Source 1 Source 2 Source 3 Source 4 Sourc.
1 2 3 45 6 7 8 Pair 2 Pair 1 Pair 4 Pair 3 Page 6 INST ALLING YOUR E SERIES SYSTEM I. Installing and T erminating Cables The basic installation requires two different types of cables. The keypads communicate with the E6M amplifier through Cat-5 data cable (4 twisted-pair).
Fig. 2: E-Z Port Backside Page 7 The location of the E-Z Port is mostly determined by where you locate the E6M amplifier . All Cat-5 cables should be terminated and routed to this location. Once this is done, installation of the E-Z Port is easy . Plug each o f the keypad cables into one of fifteen available jacks on the back of the E-Z Port (Fig.
IR EMITTER OUTPUTS +12V OUTPUT PULSE SUM AUDIO OUTPUT CONNECT TO NV-E6X ODD NUMBERED OUTPUTS ARE IDENTICAL (TIED TOGETHER) EVEN NUMBERED OUTPUTS ARE IDENTICAL (TIED TOGETHER) Page 8 123456 Each piece of source equipment is connected to the E6M amplifier with RCA cables.
VI. Connecting the E6M to the E6X Page 9 * FOR SECOND KEYP AD 1000 0100 1 100 0010 1010 1 2 3 4 5 00 01 10 11 B,T+4 100+4 10K+4 FLA T 0 1 ON OFF 0 1 ON OFF SW # 1,2,3,4 ZN# SRCE GROUP 01 10 111 0 0001.
12 34 56 7 8 O N 12 34 56 7 8 O N 12 34 56 7 8 O N 12 34 56 7 8 O N 12 34 56 7 8 O N 12 34 56 7 8 O N 12 34 56 7 8 O N 12 34 56 7 8 O N 12 34 56 7 8 O N 12 34 56 7 8 O N 12 34 56 7 8 O N 12 34 56 7 8 O N Page 10 The single most important aspect of the installation is to address the keypads correctly .
12 34 56 7 8 O N 12 34 56 7 8 O N 12 34 56 7 8 O N Page 1 1 Switches 5 and 6 allow you to set a permanent EQ in that particular zone. Y ou can set that zone to have a +4dB boost at 100Hz, a +4dB boost at 10kHz, a +4dB boost at both frequencies, or a flat response (Fig.
REFER TO MANUAL 0123 DIAGNOSTIC CONTROL -INPUT- -OUTPUT- MUTE UNIT ON +12V G N.O. G X. Using the Mute and Unit On Pins Page 12 All NUVO products come with the wireless remote.
REFER TO MANUAL 0123 DIAGNOSTIC CONTROL -INPUT- -OUTPUT- MUTE UNIT ON +12V G N.O. G Page 13 The MPU Diagnostic LEDs serve several functions. One function is the lowest assignable address. This is an aid in sequentially assigning the appropriate address on each keypad.
Fig. 16: Changing Keypad Buttons XII. Changing the Buttons on the NV-EKP XIII. NV-MI1 Mute Interface B A C K Page 14 NV-MIB1 TO E6m TELCO IN The NV-EKP keypads come with 30 preprinted, interchangeable buttons. These have a variety of audio source labels for customizing the E Series system to match the audio components being used.
Page 15 Symptom Probable Cause Remedy When a keypad is plugged in, there is a loud pop through the speakers and the keypad does not work. Improperly wired Cat-5 cable. Check that you are using the 568A wiring standard (See Section I. Installing and T erminating Cables).
Page 16 NUVO NV-E6M Specifications Power Amplifier Section Continuous A verage Output Power 23W T wo channels driven 30-20kHz @ 1% THD Rated Distortion (1/2 power) 0.
NUVO T echnologies Inc., 4940 Delhi Pike, Cincinnati, OH USA T el: (866) 796-4904 Fax: (513) 347-2298 www .nuvotechnologies.com.
デバイスNuvo NV-E6XSの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Nuvo NV-E6XSをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNuvo NV-E6XSの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Nuvo NV-E6XSの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Nuvo NV-E6XSで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Nuvo NV-E6XSを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNuvo NV-E6XSの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Nuvo NV-E6XSに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNuvo NV-E6XSデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。