Pr o Plus 2 dive computer operating manual OCEANIC ®.
2 LIMITED TWO-YEAR WARRANTY For details, refer to the Product Warranty Registration Card provided. COPYRIGHT NOTICE This operating manual is copyrighted, all rights are reserved.
3 CONTENTS LIMITED TWO-YEAR W ARRANTY ............................................................................................................................... .2 NOTICES ..........................................................................
4 CONTENTS (continued) ACTIV AT ION AN D SETUP ............................................................................................... 21 ACTIV A TION ............................................................................................
5 CONTENTS (continued) WARNING: Prior to diving with the Pro Plus 2, you must also read and understand the Oceanic Dive Computer Safety and Reference Manual. POST DIVE MODES .............................................................................
6 M MAX DEMO PSI BAR 10 20 30 40 50 60 05 O 2 TOO FAST O 2 DECO ATR FEET MAX O 2 N PRO PLUS 2 Components: a . Select (right) Button b . LED Warning Light c . Smartglo Sensing Port d . Advance (front) Button e . Air Time Remaining Bar Graph f . O2 (oxygen) Bar Graph g .
7 FE A TURES and DISPLA Y S WARNING: Prior to diving with the Pro Plus 2, you must also read and understand the Oceanic Dive Computer Safety and Reference Manual which provides Important Warnings and Safety Recom- mendations as well as general product information.
8 M MAX DEMO PSI BAR 10 20 30 40 50 60 05 O 2 TOO FAST O 2 DECO ATR FEET MAX O 2 N INTRODUCTION Welcome to Oceanic and thank you for choosing the Pro Plus 2 ! It is extremely important that you read this Operating Manual in sequence and under- stand it completely before attempting to use the Pro Plus 2.
9 DECO ATR O 2 N 2 BAR GRAPHS Tissue Loading Bar Graph (TLBG) The Tissue Loading Bar Graph (Fig. 2a) represents tissue loading of nitrogen, showing your relative no decompression or decompression status.
10 10 20 30 40 50 60 05 TOO FAST O 2 DECO ATR O 2 N 2 Oxygen Accumulation Bar Graph (O2BG) The O2 Bar Graph (Fig. 3a) represents oxygen loading, showing the maximum of either per dive accumulated oxygen, or 24 hour period accumulated oxygen.
11 PSI 10 20 05 ATR FEET O 2 N 2 Air Time Remaining Bar Graph (ATRBG) The Air Time Remaining Bar Graph (Fig. 5a) provides a graphic representation of the time that you can remain at your present depth and then, following a safe ascent, surface with a predetermined reserve of breathing gas.
12 MAX PSI 10 20 05 ATR FEET O 2 N 2 ALPHA / NUMERIC DISPLAYS Cylinder Pressure Display Cylinder Pressure (Fig 6a) is displayed any time the Pro Plus 2 is connected to a pressurized cylinder and in an active operating mode. Values of pressure are displayed numerically from 10 PSI (.
13 PSI 10 20 05 ATR FEET O 2 N 2 Time and Date Displays Time displays are shown in hour:minute format (i.e., 1:16 represents 1 hour and 16 minutes, not 116 minutes!). The colon that separates hours and minutes blinks once per second when the display is indicating real time (e.
14 NOTE: Each numeric and graphic display represents a unique piece of informa- tion. It is imperative that you understand the formats, ranges, and values of the information represented to avoid any possible misunderstanding that could result in error.
15 Situations that will sound the Alarm, if it is turned ON (a user setting), include - • Entry into Decompression Mode. • Air Time Remaining Bar Graph Alarm (a user setting). • Air Time Remaining = 5 minutes. • Air Time Remaining = 0 minutes.
16 ATR O 2 N 2 SMARTGLO ® BACKLIGHT To activate the Backlight - press the Right (Select) button. • The Smart Glo ® feature senses the intensity of natural light present.
17 PSI ATR O 2 N 2 Fig. 9 - Low Battery Condition Low Battery Condition • Voltage level is checked upon activation and every 10 minutes during operation. • When 75 % of the Rated Power has been consumed, only the lower bar of the Indicator will be displayed and the full icon will flash (Fig.
18 • If the unit did not display a Low Battery Condition prior to entering the Dive Mode, and a Low Battery Condition occurs during the dive, there will be sufficient Battery power to maintain unit operation for the remainder of that dive. The Battery Indicator will appear after the dive upon entry into Surface Mode.
19 Fig. 11 - FO2 set for 21% Once a dive is made with the unit set as a Nitrox Computer (FO2 set for a numerical value), it cannot be programmed to operate as an Air Computer until 24 hours after the last dive. 'Air' will not be displayed as an option in the FO2 Mode.
20 Fig. 13 - FO2 Default OFF R E S P O N S I B L E D I V E R If the Default function is set to OFF (Fig. 13), the FO2 value for repetitive dives remains the same as previously set until the set point is manually changed. WARNING: When the unit shuts off, the FO2 set point will default to AIR regardless if the 50% Default is set ON or OFF.
21 ACTI V A TION and SETUP WARNING: Prior to diving with the Pro Plus 2, you must also read and understand the Oceanic Dive Computer Safety and Reference Manual which provides Important Warnings and Safety Recom- mendations as well as general product information.
22 ACTIVATION To Activate the Pro Plus 2, press and release the Left (Advance) Button. • Upon manual activation, the unit will enter Diagnostic Mode (Fig. 14), displaying all segments of the LCD as 8's, followed by dashes (- -), then a countdown from 9 to 0.
23 SURFACE MODE Surface Mode (Fig. 15), identified by the Surface Time icon, follows Diagnostic Mode after Activation. Information includes Dive Number '0' (no dive made yet), Temperature (and icon), Time of Day (with icon), the Battery Consumption Indicator, and Surface Time (with flashing colon).
24 SET MODES Settings are divided into 2 categories. Set Mode #1 includes several settings that you would change more often and Set Mode #2 includes those items not likely to change once you set them. Set Mode 2 can be accessed by first entering settings in Set Mode 1, or by bypassing Set Mode 1.
25 MAX ATR O 2 N 2 ENTERING SETTINGS -SET MODE #1 TO SET - FO2 (while in the Surface Mode) Factory set for AIR, FO2 can also be set to values between 21 and 50% in increments of 1%. • Press Both buttons simultaneously, release when SET: 1 appears (2 seconds).
26 ATR FEET MAX O 2 N 2 TO SET - MAX DEPTH ALARM (while in the Surface Mode) Factory set for 330 feet, the Alarm can be set to values between 30 feet (3 meters) and 330 feet ( 99 meters) in increments of 10 feet (3 meters). • Press Both buttons simultaneously, release when SET: 1 appears (2 seconds).
27 ATR O 2 N 2 TO SET - ELAPSED DIVE TIME ALARM (while in the Surface Mode) Factory set for 3:00 (hr:min), the Alarm can be set to values between 0:10 and 3:00 (hr:min) in increments of 5 minutes. • Press Both buttons simultaneously, release when SET: 1 appears (2 seconds).
28 ATR O 2 N 2 PC INTERFACE PC Interface is not a setting, it is included in the Set 1 menu for easy access when data in the unit's memory is to be downloaded (copied) to the PC download software program for storage and viewing.
29 ATR O 2 N 2 ENTERING SETTINGS -SET MODE #2 These settings are ones that are not likely to change. To save time at the dive site, verify the set points and adjust them as desired prior to departing on the day's dive trip.
30 ATR O 2 N 2 TO SET - HOUR FORMAT (while in the Surface Mode) Factory set for 12 Hr (12: Am to 11: Pm), the Format can also be set for 24 Hr (0: to 23: hours). • Press Both buttons simultaneously, release when SET: 2 appears (4 seconds). • Press and release the Left (Advance) button, the Units screen appears with the set point flashing.
31 ATR O 2 N 2 ATR O 2 N 2 TO SET - TIME (while in the Surface Mode) Set for factory local time, the Time can be set to values between 1:00 and 12:59 (AM/PM) or 0:00 and 23:59. • Press Both buttons simultaneously, release when SET: 2 appears (4 seconds).
32 ATR O 2 N 2 ATR O 2 N 2 ATR O 2 N 2 TO SET - DATE (after setting Time) Factory set for the factory local Date, the Date can be set to values between 01/01/01 and 12/31/20. • After having set and accepted the Time, the Date ap- pears with the graphic dAY, and Year value flashing (Fig.
33 ATR O 2 N 2 TO SET - AUDIBLE ALARM (while in the Surface Mode) Factory set for ON, the Alarm can be also be set to OFF. This setting also applies to the red LED Warning Indicator that is synchronized with the Audible Alarm. When set OFF, the Alarm will not sound during the condi- tions described on page 14.
34 DECO ATR O 2 N 2 TO SET - MAXIMUM TISSUE LOADING BAR GRAPH (TLBG) ALARM (while in the Surface Mode) Factory set for DECO (all 8 segments), the Maximum Tissue Loading Bar Graph (TLBG) Alarm can be set to values between DECO (all 12 segments) and 1 segment.
35 10 20 30 40 50 60 05 ATR O 2 N 2 TO SET - AIR TIME REMAINING BAR GRAPH ALARM (while in the Surface Mode) Factory set for 5 minutes, the Air Time Remaining Bar Graph Alarm can be set to values of 0, 5, and 10 to 60 minutes in increments of 5 minutes.
36 PSI ATR O 2 N 2 TO SET - TURN PRESSURE ALARM (while in the Surface Mode) Factory set for 00 PSI/BAR (disabled), the Turn Pressure Alarm can be set to values between 1000 and 3000 PSI (69 to 205 BAR) in increments of 250 PSI (17 BAR). • Press Both buttons simultaneously, release when SET: 2 appears.
37 PSI ATR O 2 N 2 TO SET - END PRESSURE ALARM (while in the Surface Mode) Factory set for 00 PSI/BAR (disabled), the End Pressure Alarm can be set to values between 300 and 1500 PSI (20 to 104 BAR) in increments of 100 PSI (7 BAR). • Press Both buttons simultaneously, release when SET: 2 appears (4 seconds).
38 ATR O 2 N 2 TO SET - DIVE TIME REMAINING ALARM (while in the Surface Mode) Factory set for 5 minutes, the Dive Time Remaining Alarm can be set to values between 0:00 and 0:20 (minutes) in increments of 1 minute. • Press Both buttons simultaneously, release when SET: 2 appears (4 seconds).
39 MAX ATR O 2 N 2 TO SET - MAXIMUM PO2 ALARM (while in the Surface Mode) Factory set for 1.60 (ATA), the Maximum PO2 Alarm can be set to values between 1.20 and 1.60 (ATA) in increments of .10 (ATA). • Press Both buttons simultaneously, release when SET: 2 appears (4 seconds).
40 ATR O 2 N 2 TO SET - FO2 50% DEFAULT (while in the Surface Mode) Factory set ON, the FO2 50% Default feature can be set to OFF. The effects of this feature being ON or OFF are described on page 19. • Press Both buttons simultaneously, release when SET: 2 appears (4 seconds).
41 ATR O 2 N 2 TO SET - BACKLIGHT DURATION (while in the Surface Mode) Factory set for 3 seconds, the Backlight Duration can be set to values of 0 (disabled), 3, or 7 seconds. This is the length of time the Backlight stays On after the button is released.
42 ATR O 2 N 2 TO SET - PC SAMPLING RATE (while in the Surface Mode) Factory set at 15 seconds, the Sampling Rate can be set at values of 2, 15, 30, or 60 seconds, or 2, 5, or 10 feet (.5, 1.5, or 3 meters). • Press Both buttons simultaneously, release when SET: 2 appears (4 seconds).
43 ATR O 2 N 2 TO SET - USER SET DIGITAL GAUGE MODE (while in the Surface Mode) Factory set OFF, Digital Gauge Mode can also be set ON. The effects of this feature being ON or OFF are described on page 64. • Press Both buttons simultaneously, release when SET: 2 appears (4 seconds).
44 ATR O 2 N 2 TO SET - WATER ACTIVATION (while in the Surface Mode) Factory set for ON, the Water Activation feature can also be set for OFF (disabled) to prevent inadvertent activation during travel or storage. When set ON, the Pro Plus 2 will automatically Activate when immersed in water.
45 PLAN and DIVE MODES WARNING: Prior to diving with the Pro Plus 2, you must also read and understand the Oceanic Dive Computer Safety and Reference Manual which provides Important Warnings and Safety Recom- mendations as well as general product information.
46 PRE DIVE PLANNING SEQUENCE TM Oceanic strongly recommends that you review the Pre Dive Planning Sequence (PDPS) prior to every dive to help you plan your dive as required to avoid exceeding no decompression or oxygen exposure limits.
47 To access the Pre Dive Planning Sequence (while in the Surface mode) - • Press the Left (Advance) button 1 time • Press and release the Right (Select) button to advance through the Depths/Times, one screen at a time; and then to Surface Mode. • Press the Left (Advance) button to access Fly Mode.
48 PSI 10 20 05 ATR FEET O 2 N 2 NOTE: The Pro Plus 2 will store oxygen accumula- tion calculations for up to 10 dives conducted during a 24 hour period. If the maximum limit for oxygen loading has been exceeded for that day (24 hour period), all of the segments of the O2 bar graph will be displayed flashing .
49 PSI 10 20 30 05 TOO FAST ATR FEET O 2 N 2 PSI 10 20 05 ATR FEET O 2 N 2 OXYGEN ACCUMULATION BAR GRAPH (Fig. 46a) If FO2 was set for a numerical value (nitrox), the Oxygen Accumulation (O2) Bar Graph will add segments (green toward red) to represent oxygen accumulation for that dive, or 24 hour period, whichever amount is greater.
50 PSI 10 20 05 ATR FEET O 2 N 2 AIR TIME REMAINING BAR GRAPH The Air Time Remaining Bar Graph (Fig. 48a) displays remain- ing breathing gas times of 60 minutes and less. As time remaining decreases, segments are removed from the bar graph from the right (green) toward the left (red) in increments of 5 minutes (from 60 to 0 minutes).
51 PSI 10 20 05 ATR FEET O 2 N 2 During conditions in which Cautionary type information is displayed (e.g., No Decom- pression Safety Stop, Decompression, High PO2, etc.), there is a Main Display of impor- tant information relevant to the specific condition.
52 No Decompression Dive Mode - Display #2 (Fig. 50) Information includes Current Depth, Max Depth for that dive and icon, Elapsed Dive Time and icon, Dive Time Remaining and icon, Tank Pressure, and the applicable bar graphs. • Press and release the Left (Advance) button again to view Display #3.
53 No Decompression Dive Mode - Secondary Display (Fig. 53) To view, press the Left (Advance) button for 2 seconds. Information includes Current Depth, Air Time Remaining (and Mode icon), and applicable bar graphs. The Display will remain on the screen for 3 seconds then revert back to the Display previously selected (#1, 2, 3, 4).
54 PSI 10 05 DECO ATR FEET O 2 N 2 DECOMPRESSION DIVE MODE The Pro Plus 2 is designed to help you by providing a repre- sentation of how close you are to entering Decompression. Decompression Dive Mode (Fig. 55) activates when theoreti- cal No Decompression time/depth limits are exceeded.
55 PSI 10 20 05 DECO ATR FEET O 2 N 2 Managing Decompression Stops To fulfill your decompression obligation, you should make a safe controlled ascent to a depth slightly deeper than, or equal to, the Required Ceiling Stop Depth indicated (Fig. 56a) and decompress for the Stop Time indicated (Fig.
56 Decompression Dive Mode - Display #2 (Fig. 57) Information includes - Current Depth, Maximum Depth for that dive (and icon), Elapsed Dive Time (and icon), Total Ascent Time (and Mode icon), both Arrows and the Deco Bar, and the applicable bar graphs.
57 PSI 10 20 05 DECO ATR FEET O 2 N 2 VIOLATION MODES While in Violation Modes the Alternate Displays previously described can be accessed using the Left (Advance) button, and the Backlight can be activated using the Right (Select) button.
58 PSI 10 20 05 DECO ATR FEET O 2 N 2 The added Penalty (decompression) Time will have to be 'worked off' first, before obtaining off-gassing credit. Once the Penalty Time is worked-off, and off-gassing credit begins, required decompression Stop Depths and Time will decrease toward zero.
59 MAX PSI 10 20 05 ATR FEET O 2 N 2 PSI 10 20 30 40 50 05 DECO ATR FEET O 2 N 2 Delayed Violation Mode #2 (Fig. 62) The Pro Plus 2 cannot calculate decompression times for Stop Depths much greater than 60 feet (18 meters) and offers no indication of how much time spent underwater would result in the need for a greater Stop Depth.
60 MAX PSI 10 05 DECO ATR FEET O 2 N 2 O 2 Upon ascending above 330 feet (99.9 meters), the Current Depth display will be restored, however Max Depth will only display 3 dashes for the remainder of that dive. The Log for that dive will display 3 dashes as the Max Depth achieved.
61 The Pro Plus 2 will also enter an Immediate Violation Mode 5 minutes after reaching the surface from a dive in which a Delayed Violation occurred. On the surface, Gauge Mode displays the Dive Number, Temperature, Time of Day, and Surface Interval (Fig.
62 PSI 10 20 30 05 O 2 ATR FEET O 2 N 2 PSI 10 20 30 05 O 2 ATR FEET O 2 N 2 HIGH PO2 DIVE MODE When partial pressure of oxygen (PO2) becomes equal to, or greater than, 1.
63 PSI 10 05 O 2 O 2 ATR FEET O 2 N 2 HIGH OXYGEN ACCUMULATION The O2 Bar Graph displays either oxygen accumulated during that nitrox dive, or during the repetitive nitrox dives you conduct during that 24 hour period, whichever of the two is greater at that time.
64 MAX PSI 10 05 ATR FEET O 2 N 2 MAX PSI 10 05 ATR FEET O 2 N 2 USER SET DIGITAL GAUGE MODE When Digital Gauge Mode is set for ON, the Pro Plus 2 will operate as a Digital Depth Gauge/Timer without performing nitrogen and oxygen calculations (Fig. 69).
65 POST DIVE MODES WARNING: Prior to diving with the Pro Plus 2, you must also read and understand the Oceanic Dive Computer Safety and Reference Manual which provides Important Warnings and Safety Recom- mendations as well as general product information.
66 POST DIVE SURFACE MODE When you ascend to 3 feet (1 meter) or shallower, the Pro Plus 2 will enter Surface Mode and begin counting your surface interval. TRANSITION PERIOD The first 10 minutes is, in affect, a Transition Period during which time the following information is displayed (Fig.
67 To view that dive's Log (Fig. 72) - Refer to page 64 for a description of the Log Mode displays. • Press the Left (Advance) button 1 time . • Press the Right (Select) button 1 time to view the Nitro- gen data screen. • Press the Right (Select) button again to view the Oxygen data screen (if a nitrox dive).
68 AFTER THE TRANSITION PERIOD (THE FIRST 2 HOURS) For the remainder of the first 2 hours after surfacing , information will continue to be displayed as Surface Mode (Fig. 73) and you will have full access to other modes (e.g., PDPS, Fly, Desat, Log, Set, etc.
69 To access the Time to Fly Countdown (while in Surface Mode) • Press the Left (Advance) button 2 times . • The Time to Fly counter (Fig. 75) begins counting down 10 minutes after surfacing from .
70 LOG MODE Information from your latest 24 dives is stored in the Log for viewing. The first dive of a new 'activation period' will be #1, then #2, etc. After 24 dives are accumulated, each subsequent dive will overwrite the oldest dive in the Log (i.
71 To access the Log Mode and view the First Screen (While in Surface Mode) - • Press the Left (Advance) button 4 times . • The First Screen of the most recent dive will appear displaying (Fig.
72 To view the Third Screen of the Log (Oxygen data) • Press the Right (Select) button 1 time (while viewing the Nitrogen data). Displayed will be (Fig.
73 WET CONTACTS If the graphic H2O appears during the Fly Mode (Fig. 81) and Desaturation Mode (Fig. 82) countdowns that alternate 2 hours after a dive, it is an indication that the water activa- tion contacts are bridged (still wet) and the unit must be rinsed in fresh water and thoroughly dried.
74 Fig. 83 - PC Interface DOWNLOADING DATA TO A PC Using special linking hardware, dive data can be down- loaded (copied) from your Pro Plus 2 to an IBM compatible PC program running on a Windows ® operating system.
75 SIMULA TOR (DEMO) MODE WARNING: Prior to diving with the Pro Plus 2, you must also read and understand the Oceanic Dive Computer Safety and Reference Manual which provides Important Warnings and Safety Recom- mendations as well as general product information.
76 DEMO ATR O 2 N 2 SIMULATOR MODE This mode provides you with the ability to practice various dive mode scenarios and computer functions while observing the various displays.
77 DEMO ATR O 2 N 2 PSI DEMO ATR O 2 N 2 Fig. 86 - Set Demo Calibration Fig. 87 - Set Pressure On/Off • Press and release the Right (Select) button to toggle between Gauge ON and OFF . • Press and release the Left (Advance) button to accept the setting and advance to DEMO: NI-O2 with CUR (or NEW ) flashing (Fig.
78 DEMO PSI 10 20 30 40 50 60 05 ATR O 2 N 2 ATR O 2 N 2 DEMO • Press and release the Right (Select) button to toggle between Pressure ON and OFF . • Press and release the Left (Advance) button to accept the setting and revert to Demo Surface Mode with the DEMO icon flashing.
79 DEMO PSI 10 20 05 ATR FEET MAX O 2 N 2 Descending Hint: Quick taps (<2 seconds) of the Right (Select) button starts/stops Descents and Time Acceleration.
80 DEMO PSI 10 20 05 TOO FAST ATR FEET O 2 N 2 DEMO PSI 10 05 ATR FEET O 2 N 2 Ascending Rate of Ascent can be set for 1 or 3 feet per seconds (fps) prior to start of the Ascent. To change the Rate during an Ascent, it must first be stopped. • Pressing and holding the Left (Advance) button for 2 seconds will access an Ascent Rate of 1 fps.
81 DEMO PSI ATR O 2 N 2 Surfacing from a Simulated Dive • The Simulator will enter Demo Surface Mode (Fig. 94) upon ascending to 3 feet (1 meter) or shallower. • Press and hold the Right (Select) button for 4 seconds to access Time Acceleration. The small Time Clock icon will begin flashing.
82 R E S P O N S I B L E D I V E R Be a - RESPONSIBLE DIVER at all times..
83 GENERAL WARNING: Prior to diving with the Pro Plus 2, you must also read and understand the Oceanic Dive Computer Safety and Reference Manual which provides Important Warnings and Safety Recom- mendations as well as general product information.
84 X X X X CARE AND CLEANING Protect your Pro Plus 2 from shock, excessive temperatures, chemical attack, and tampering. Protect the lens against scratches with a transparent Instrument Lens Protector. Small scratches will naturally disappear underwater.
85 To Obtain Service: Take your Pro Plus 2 to an Authorized Oceanic Dealer or send it to the nearest Oceanic Regional Distributor Facility. To return your Pro Plus 2 to Oceanic: • Record all dive data in the Log and/or download the data in memory. All data will be erased when it receives factory service.
86 NOTE: The procedures that follow must be closely adhered to. Damage due to improper Battery replace- ment is not covered by the unit's 2 year warranty. BATTERY REPLACEMENT The Battery Compartment should only be opened in a dry and clean environment with extreme care taken to prevent the entrance of moisture or dust.
87 X X X X Battery Removal Examine the Case Back to locate the Battery Hatch (Fig. 96a): • Remove the 4 screws that secure the Battery Hatch to the Housing by turning counter clockwise. • Lift the Hatch up and away from the Housing. • Lift the Battery, positive (+) end first, out of the Battery Compartment.
88 Moisture in the Battery Compartment • If moisture is found, it is best to have the unit inspected and cleaned by an Authorized Oceanic Dealer. • If it is necessary to clean the Battery Compartment, flush the it and all components with a solution of 50% white vinegar and 50% fresh water.
89 Battery Hatch Installation • Ensure that the Battery is properly oriented and the Hatch O-ring is evenly seated. • Carefully place the Battery Hatch into position so that it seats on top of the O-ring, and while holding it in place, secure it with the 4 screws by turning them clockwise.
90 CAN BE USED AS Air Computer Nitrox Computer Digital Depth Gauge/Timer NO DECOMPRESSION MODEL Basis: Modified Haldanean Algorithm 12 tissue compartments Data Base: Diving Science and Technology (DSAT) - Rogers/Powell Performance: Tissue compartment halftimes (mins.
91 OPERATIONAL MODES (DIVE) No Decompression Dive: #1 - Current Depth, Dive Time Remaining, Cylinder Pressure, Bar Graphs #2 - Current Depth, Dive Time Remaining, Max Depth, Elapsed Dive Time,.
92 DISPLAY RANGE/RESOLUTION Numeric Displays: Range: Resolution: Dive Number 0 to 2 4 1 Depth 0 t o 330 ft (0 to 99.9 m) 1 ft (.1 m ) Maximum Depth 330 ft (99.9 m) 1 ft (.1 m) FO2 Set Point Air, 21 to 50 % 1 % PO2 Value 0.00 to 5.00 ATA .
93 SPECIFICATIONS (CONTINUED) BAR GRAPHS Tissue Loading Bar Graph: segments Oxygen (O2) Bar Graph: segments No Decompression zone (green) 9 Normal zone (green) 4 No Deco Caution zone (yell.
94 OPERATIONAL PERFORMANCE (continued) Altitude: Operational from sea level to 14,000 feet (4,267 meters) elevation Measures ambient pressure every 30 minutes and when manually activated (no w.
95 OPERATIONAL PERFORMANCE (continued) Setting FO2: Automatically set for 'Air' upon activation Remains set for Air unless an FO2 numerical value is set Nitrox set points from 21.
96 OCEANIC WORLD WIDE OCEANIC USA 2002 Davis S treet San Leandro, CA 94577 T el: 510/562-0500 Fax: 510/569-5404 W eb site: http ://www.OceanicW orldWide. com Oceanic Germany - Nurnberg, Germany Tel: 49-911-324-6630 Fax: 49-911-312-999 E-mail: office@oceanic.
97 INSPECTION / SERVICE RECORD Serial Number ________________________ Date of purchase _____________________ Purchased from ______________________ Below to be filled in by an Authorized Oceanic Dealer.
98 NOTES.
99 RESET FEATURE This dive computer is configured with a RESET feature that allows data to be cleared, including Nitrogen and Oxygen calculations, FO2 set point, Log Mode entries, and Download data. WARNING: Reset after a dive and subsequent use for a repetitive dive conducted by the same diver could result in serious injury to or death.
OCEANIC ® USA 2002 Davis Street San Leandro, CA 94577 Tel: 510-562-0500 Fax: 510-569-5404 http://www.OceanicWorldWide.com © 2002 Design 200 2 Doc. No.
デバイスOceanic Pro Plus 2の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Oceanic Pro Plus 2をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはOceanic Pro Plus 2の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Oceanic Pro Plus 2の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Oceanic Pro Plus 2で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Oceanic Pro Plus 2を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はOceanic Pro Plus 2の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Oceanic Pro Plus 2に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちOceanic Pro Plus 2デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。