DPF700 Dual Relay Option Board for the DPF700 Meter www .omega.com e-mail: info@omega.com U ser ’ s Guide Shop on line at.
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply . OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
i PREF A CE MANU AL OBJECTIVES This manual shows you how to install and use the Dual-Relay option board with the DPF700 meter . In this manual we provide procedures for: * Setting up the Dual-Relay op.
ii T ABLE OF CONTENTS 1.1 UNP ACKING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 1.2 SAFETY CONSIDERA TIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.1 UNP A CKING Remove the Packing List and verify that all equipment has been received. If there are any questions about the shipment, use the phone number for the Customer Service Department nearest you. Upon receipt of shipment, inspect the container and equipment for any signs of damage.
2 2 2.1 INST ALLING THE DU AL-RELA Y OPTION BO ARD T o install the dual-relay option board, follow these steps (refer to the Figure 2-1): ! CA UTION: T he meter has no power-on switc h, so it will be in operation as soon as you apply power . ! IMPORT ANT : Disconnect the power fr om the unit before installing this option boar d.
3 2.2 SETTING UP THE DU AL-RELA Y OPTION BO ARD Y ou may enter a setpoint from -99999 to 999999 with a decimal point in any of the following positions: 9.9.9.9.9.9. After applying the scale factor and of fset, the displayed measurement is compared to the setpoint values.
2 2.2 SETTING UP THE DU AL-RELA Y BO ARD (Continued) Figure 2-2. Setpoint Example Illustr a tion T o convert Setpoint LO to a second high setpoint, set software switch 3 of the configuration menu to 1 ( ConFIG = XX1XXX ). LO ALARM becomes active when the reading is greater (more positive) than that setpoint.
5 2.3 ELECTRICAL CONNECTION AND SPECIFICA TION Each relay has a form C contact. Refer to Figure 2-1 and Figure 2-3 to locate contacts and S5 switch. * Install S5-A to control Relay 2 with hysteresis action. * Install S5-B to control Relay 2 with setpoint HI.
3 6 3.1 RELA Y OUTPUT OPTION BO ARD SPECIFICA TIONS 2 Form "C" on/off relays. Configurable for latched and unlatched by software. Max Current: 5 Amps, resistive load.
WARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA W arranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time.
M1799/1203 1 1689ML-99 Rev . C W her e Do I Find Ev er ything I Need for Pr ocess Measurement and Contr ol? OM EGA…Of Cour se! Shop on line at www.omega.
デバイスOmega Engineering Dual Relay Option Board DPF700の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Omega Engineering Dual Relay Option Board DPF700をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはOmega Engineering Dual Relay Option Board DPF700の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Omega Engineering Dual Relay Option Board DPF700の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Omega Engineering Dual Relay Option Board DPF700で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Omega Engineering Dual Relay Option Board DPF700を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はOmega Engineering Dual Relay Option Board DPF700の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Omega Engineering Dual Relay Option Board DPF700に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちOmega Engineering Dual Relay Option Board DPF700デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。