http://www .omega.com e-mail: info@omega.com ® U ser’s Guide L VCN700 S er i es Multi-Point Ultrasonic Level Switch WARRANTY /DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase.
Step One SPECIFICA TIONS Range: L VCN704: 2" to 4' (5 cm to 1.2m) L VCN709: 4" to 9.8' (10 cm to 3m) L VCN716: 4" to 16.4' (10 cm to 5m) L VCN126: 8" to 26.2' (20 cm to 8m) Repeatability: 0.25" (6 mm) Adjustability: Over entire range Hysteresis: L VCN704/709: 0.
INTR ODUCTION TECHNOLOGY Step Three A. Application: The general purpose ultrasonic level switch pro- vides non-contact level detection up to 26’ or 8m with 3 relays.
Step Four Step Five CALIBRA TION A. Introduction: The switch has two modes, the RUN and CAL modes. In the RUN mode, the switch is operational and the relay(s) will energize or de-ener gize at the calibrated set point distances. In the CAL mode, the relay set point distances and states may be target-cal- ibrated into memory .
Step Seven Step Six CALIBRA TION B. Calibration T ools: T o target calibrate the switch set points, you will need the appropriate power supply (95-250 V AC or 12-28 VDC for DC version), tape measurer , flat reflective target such as a wall, and optional Omega box insert for use as a product holder .
Step Eight PR OGRAMMING Step Nine PR OGRAMMING C. Programming a High and Low Level Out of Bounds Alarm: After having powered the switch with the appropriate supply voltage, entered the CAL mode, selected a relay channel and erased any previously input set points, follow the below procedure: 1.
Step T en PR OGRAMMING E. Programming A utomatic Empty: After having powered the switch with the appropriate supply voltage, entered the CAL mode, selected a relay channel and erased any previously input set points, follow the below procedure: 1. Stretch the tape measurer out to the appropriate distance in between the switch and target.
A. Fitting Selection: Check the switch part number to determine the required fitting mount size and thread type. The switch is commonly installed in tank adapters, flanges, brackets or stand pipes.
Step Fourteen High Alarm VA C INPUT HOT NEUTRAL Motor Starter (Pump) RELA Y 1 RELA Y 2 RELA Y 3 L 1 L 2 POWER VA C Cal. Run High Low Select Low Alarm VA C INPUT NEUTRAL HOT High Alarm VDC INPUT HOT NEUTRAL Motor Starter (Pump) RELA Y 1 RELA Y 2 RELA Y 3 (+) (-) POWER VDC Cal.
Relay 1 Relay 2 Energize De-Energize Energize De-Energize Backup Primary Stop Relay 1 Relay 2 Energize De-Energize Energize De-Energize Backup Primary Stop Duplexing Control Operation Alternating Cont.
デバイスOmega Engineering LVCN700 Seriesの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Omega Engineering LVCN700 Seriesをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはOmega Engineering LVCN700 Seriesの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Omega Engineering LVCN700 Seriesの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Omega Engineering LVCN700 Seriesで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Omega Engineering LVCN700 Seriesを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はOmega Engineering LVCN700 Seriesの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Omega Engineering LVCN700 Seriesに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちOmega Engineering LVCN700 Seriesデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。