M4548-0607 omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info U ser ’ s Guide MADE IN Shop online at Manual and Installati on Instructions Four Zone T emperature Monitor a.
2 23 WARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time.
http://{Device IP Address}/ltx_conf.html Click on the “Server Properties” button. Enter the Subnet Mask and/or Gateway Address and click “Update Set- tings” Be sure to enter the correct Subnet Mask and Ga teway Address f or the ne t- work the OMA-V520-DCP is on.
4 General purpose, dry contact input Wiring Diagram Alarm Relay Output Plug in Thermocouple Terminals 1234 K + K + K + K + Sensor 1 Sensor 2 Sensor 3 Sensor 4 K + K + K + K + K type thermocouples with integrated spade connectors 8 W atch the display and no te any messages present.
Temperature Monitor and Alarm will repeat the wa rning message. This warning message can be repeated up to 2 times by changing the pro- gramm ed value.
A ccessing the Four Zone Temp erat ure Monitor over the phone 1 From another phone line call the Four Zo ne Temperature Monitor and Alarm. The device will pick up after the progra m med num ber of rings (Def ault is 1). 2 To access all funct ions, enter the 4-digit "Full Access" PIN.
18 Sensor Reading A fter Callouts If the Four Zone Temperature Monitor has called all programmed telephone numbers and not made contac t it will wa it 20 minutes before attempting to callout again. Peri odically, the time before callouts resume will be display ed.
ming this sensor and return to step 1.b j) You w ill hear “ Enter number then press pound” k) Enter the value then press # . ► Use * to program a negative number (i.e. *20 = -20º ) ► Acceptable range is -999 to 999 l) You w ill hear the value you just entered (i.
16 1: ok 2: ok 3: n/c 4: n/c Sensor Present Sensor Present Sensor Not Detected Sensor Not Detected Start Up W hen starting up, the Four Zone Temperature Monitor checks each temperature sensor input to verify that a sensor is connected. If a sensor is connected and has a reading within range, “ok” will be printed next to that sensors label.
10 Acces sing the Program Menu From the Main Menu, press 3 ► The "Full Access" PIN will be reques ted if the " Acknowledge Only " PIN w as entered init ially. If the corr ect "Full Access" PIN is not entered, the Four Zone Temperature Monitor and Alarm w ill hang up.
Changing the Callout Delay Time W hen a refr igerator o r freezer ’s temp erature is out of r ange the Fo ur Zone Temperature Monitor and Al arm will wait this progra mm able amount of tim e before making telephone alert calls.
12 other device. See the Frequently Asked Questions section for details. 1 From the Progr am Menu, p ress 4 to set the number of rings 2 You w ill hear the program med num ber of rings 3 You will hear “Press one to change.
デバイスOmega Engineering OMA-VM520の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Omega Engineering OMA-VM520をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはOmega Engineering OMA-VM520の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Omega Engineering OMA-VM520の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Omega Engineering OMA-VM520で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Omega Engineering OMA-VM520を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はOmega Engineering OMA-VM520の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Omega Engineering OMA-VM520に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちOmega Engineering OMA-VM520デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。