AnO.VfEG.4 Group Company OjyjEGA ENGINEERING, INC. Operator ’ s Manual.
M446/026 1 0 Copyright 1986 OMEGA ENGINEERING, INC. All rights reserved including illustrations. Nothing in this manual may be reproduced in any manner, either wholly or in part for any purpose whatsoever without written permission from OMEGA ENGINEERING, INC.
4/s 5/6 PART V SERVICE 1. 2. 3. 4. Block diagram 7 Table I 8 Transmitter dimensions input/output connections and Adjustment pot location Table II 9 10 1 2 2 2 3 4 - CALIBRATION 1. Calibration interval 5 2. Equipment required 5 3. Calibration procedure & TECHNICAL INFORMATION 1.
-l- @ 60 Hz Manual or auto to 95% 600 VDC or peak -120dB +60°C 0 .Ol%/Volt -10 to 3% digit LC D pH k.01 pH ht.01 02%/OC (Display and current out) f. pH *.
-2- "U" bolts should bolt to the heavy PVC mounting feet. "U" bolts and nuts. The - attachment to a round pipe requires #lO screws and nuts. 2.3 Pipe Mounting - mounting to a flat surface requires the heavy PVC mounting feet be attached to the box.
-3- ppm/OC. f ppm/'C or wire wound *50 25'C compensation. The re- sistor used should be metal film 8.66K resistor is normally supplied with the transmitter, this value is correct for Manual temperature compensation requires only a resistor at the terminal strip connection marked with a resistor symbol.
-4- iO.0 buffer solution. to the user. pH or a adjustment.when the probe is in a The choice of a 4.0 or 10.0 is up 4.0 pH buffer solution "pH CAL" with the for a reading of 7.0 and the "Slope" probe in a 7.0 pH value of the buffer solution.
-5- pH units. 112 in place. The output is adjustable for a span of 2 to 6 fl and #2 is with jumpers pH point of the range. The adjustments are sensitive and interactive, do not attempt large changes, work both ad- justments in turn with small changes.
-6- pH levels. mA at the desired mA and the "Span" for 20 PII simulator at the input, a resistor at the temperature compensation terminals. (Refer to Table I for the correct resistor and millivolt values). Adjust the "Zero" for 4 h ZERO adjustments interact and require going back and forth between them.
- --- _ - _ ----!-! -7 ‘ i _ iI __ l I <.
-a- . 1.58K 1.98K 3.08K 4.74K 5.94K 8.66K 20.27K -518.2 Temp. Comp. Res. -4-4-8.8 -476. 6 -504. 4 -148.1 10 -162. 6 -177. 5 -186. 4 -192. 4 -204. 3 -216. 2 -222. 1 11 -216. 8 -236. 6 -248. 5 -256. 5 -272. 4 -288. 2 -296. 1 12 -270. 1 -295. 8 -310. 7 -320.
1 v- - 9 b.
-l O - .t 7 ’ D I A . HOLE EL CUT-OUT TABLE II PAN.
06907-0047 (203) 359-1660 Telex: 996404 Cable: OMEGA FAX: (203) 359-7700 Cornpuny One Omega Drive, Box 4047 Stamford, Connecticut AnO.MEGrl Group Benchtopllaboratory Meters Cl Controllers Cl Calibrato.
デバイスOmega Engineering PHTX-11の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Omega Engineering PHTX-11をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはOmega Engineering PHTX-11の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Omega Engineering PHTX-11の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Omega Engineering PHTX-11で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Omega Engineering PHTX-11を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はOmega Engineering PHTX-11の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Omega Engineering PHTX-11に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちOmega Engineering PHTX-11デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。