omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info FTB600B Series Ultra-Low Flow Sensors Shop online at U ser ’ s Guide.
OMEGAnet ® On-Line Service Internet e-mail omega.com info@omega.com It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives.
TABLE OF CONTENTS FTB600B Series Ultra-Low Flow Sensors i Section Page Section 1 Introduction ...................................................................... 1 A. General Description .................................................... 1 B. Principle of Operation .
ii FTB600B Series Ultra-Low Flow Sensors NOTES:.
1 1 FTB600B Series Installation IMPORTANT: READ INSTRUCTIONS THOROUGHLY BEFORE INSTALLING FLOW METER Section 1 - Introduction A. General Description The FTB600B Series is an axial paddle wheel turbine type flow meter based on the pelton wheel principle.
2 FTB600B Series Installation 1 C. Material Characteristics of PVDF (Polyvinylidene Fluoride) 1. Material of construction Trade name - Kynar All wetted parts of the FTB600B Series are PVDF, excluding the O-ring. Wetted parts include any part of the meter that will or could come in contact with the fluid.
3 2 FTB600B Series Operating Parameters Section 2. - Operating Parameters A. Temperature Since the FTB600B Series has printed circuit boards molded into the body of the meter it is strongly recommended that 180°F not be exceeded. Exceeding 180°F can cause irreparable damage to the circuit boards.
4 FTB600B Series Operation Parameters 2.
5 FTB600B Series Operating Parameters 2 C. Recommended Viscosity Range 1-5 cSt (w/o correction) The effects of changing viscosity on the FTB600B Series are the same as any other turbine flow meter.
6 3 FTB600B Series Silicone Treatment Section 3 - Silicone Treatment Silicone treatment is standard for all types of the FTB600B Series series electronics.
7 4 FTB600B Series Infrared Sensors Section 4 - Infrared Sensor A. Supply Voltage 24 Vdc. Do not exceed 24 Vdc. Doing so can cause overheating and eventual failure of all PC boards. Printed circuit boards are non- repairable. B. Frequency Output 1. Square wave pulse, unscaled (See Figure 4-1) 2.
8 FTB600B Series Infrared Sensors 4 C. Frequency Ranges for (non-cartridge models) pulses/l Model Frequency (Hz) K-Factor FTB601B 60 to 1200 36,000 FTB602B 40 to 1200 8,000 FTB603B 27 to 800 3,200 FTB604B 20 to 600 1,200 FTB605B 18.75 to 562 450 FTB606B 15 to 450 225 D.
9 FTB600B Series Infrared Sensors 4 Figure 4-1. Output Frequency Waveforms.
10 5 FTB600B Series Installation Section 5 - Installing the FTB600B Series in the fluid line. A. Make sure the fluid is compatible with PVDF (polyvinylidene fluoride) and meets viscosity, pressure and temperature parameters of the FTB600B Series. The fluid must also meet filtration requirements as listed in 3D.
11 FTB600B Series Installation 5 Figure 5-1. Supply Voltage and Signal Output Connections.
12 FTB600B Series Installation 5 Table 5-1. Piping Table.
13 FTB600B Series Installation 5 Table 5-1. Piping Table Con't..
14 6 FTB600B Series Specifications Section 6 - Specifications Accuracy: ±3% of reading Repeatability: ±0.1% of reading Linearity: ±1% of reading Viscosity Range: 1 to 15 centistokes Working Pressur.
15 7 FTB600B Series Pressure Drop Curves Section 7 - Pressure Drop Curves Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB601 50 0.5 0 1.0 Liters/minute kP a 1.
16 FTB600B Series Pressure Drop Curves 7 Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB602 250 2.0 0 4.0 Liters/minute kP a 8 .0 6.0 10.0 200 150 100 50 0.
17 FTB600B Series Pressure Drop Curves 7 Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB603 200 51 0 1 5 0 Liters/minute kP a 160 1 8 0 140 100 8 0 60 40 20 120 0.
18 FTB600B Series Pressure Drop Curves 7 Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB604 200 10 20 30 0 Liters/minute kP a 160 1 8 0 140 100 8 0 60 40 20 120 0.
19 FTB600B Series Pressure Drop Curves 7 Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB605A 160 140 120 100 8 0 60 40 20 10 20 30 40 50 60 0 Liters/minute kP a 0.
20 FTB600B Series Pressure Drop Curves 7 Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB606A 1 8 0 160 140 120 100 8 0 60 40 20 10 20 30 40 50 60 70 8 09 0 0 Liters/minute kP a 0.
FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA: 1. Purchase Order number under which the product was PURCHASED, 2. Model and serial number of the product under warranty, and 3. Repair instructions and/or specific problems relative to the product.
TEMPERATURE 䡺 ⻬ Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies 䡺 ⻬ Wire: Thermocouple, RTD & Thermistor 䡺 ⻬ Calibrators & Ice Point References 䡺 .
デバイスOmega FTB600Bの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Omega FTB600Bをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはOmega FTB600Bの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Omega FTB600Bの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Omega FTB600Bで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Omega FTB600Bを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はOmega FTB600Bの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Omega FTB600Bに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちOmega FTB600Bデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。