1 INTRODUCTION This instrument is a portable easy to use 3 digit, compact-sized digital infrared thermometer with laser sighting designed for simple one hand operation. Meter comes with Backlit LCD display, Auto-hold function and auto power down (20 seconds approx.
2 CAUTION • Do not use the unit near any device which generates strong electromagnetic radiation or near a static electrical charge, as these may cause errors. • Do not use the unit where it may be exposed to corrosive or explosive gases. The unit may be damaged, or explosion may occur.
3 SPECIFICATIONS GENERAL Display: 3½ digit liquid crystal display (LCD) with maximum reading of 1999. Low battery indication: the " " is displayed when the battery voltage drops below the operating level. Measurement rate: 1 times per second, nominal.
4 Laser Specifications Laser safety classification of Class II Wave Lenght: Red (650nm). Operating Distance: 2 to 50 feet. Power out: <1mW , class II laser product. ELECTRICAL Temperature Range: -4°F to 1022°F / -20°C to 550°C. Display Resolution: 1°F / 1°C.
5 Spot size increases with distance from the probe tip as shown (Spot Diameter measured at 90 % Energy) CAUTION: Use of controls or Adjustments or performance of Procedures other than those Specified herein may result in Hazardous radiation exposure.
6 OPERATING INSTRUCTIONS Auto Power-down function If unused for about 20 seconds, the unit will power-down automatically. Press MEAS button resumes power-on mode. SET MODE disables auto power-down feature. Turning the Power on When the power is down, press MEAS button to turn on the meter.
7 Laser Sighting Press " " button to on the " " annunciator. If " " annunciator is on, press MEAS button and the laser beam will turn on and " " annunciator will blink. Releasing MEAS button turns off the laser beam.
8 Continuous Measurement 1. In the power down mode, holding the MODE key down and then pressing the MEAS key will put the unit into the continuous measurement mode. 2. When the MEAS key is pressed again to stop measuring temperature and automatically hold the display reading, the meter power down automatically after 20 seconds.
9 MODE SELECTION AND OPERATION Press MODE button switches the mode around the cycle e ® ALM Hi ® ALM Lo ® MAX ® MIN ® HOLD. HOLD :Releasing MEAS button stops measuring temperature, the HOLD indication appears, and the measured temperature is held.
10 NOTE: If, from the power down condition, the MEAS key is held down for more than four second, MAX/MIN record starts. SET MODE & Numeric input key "SET" annunciator appears when a numerical value can be set (during setting of e , ALM Hi and ALM Lo).
11 How to specify the thermal emissivity ( e e e e e ) 1. Stick black body tape on the object whose temperature is to be measured, or spray it with black body spray.
12 OPERATION 1. When the power is down, pressing MEAS button turns on the power. 2. Use " " button to select turn on or turn off the display Back-Light. 3. Use " " button to select turn on or turn off the Laser beam. 4. Press the MODE button, if necessary to set the thermal emissivity value ( e ).
13 MEASUREMENT CONSIDERATIONS 1. Theory of Measurement Every object emits infrared energy in accordance with its temperature. By measuring the amount of this radiant energy, it is possible to determine the temperature of the emitting object.
14 4. Emissivity All objects emit invisible infrared energy. The amount of energy emitted is proportional to the object's temperature and its ability to emit IR energy. This ability, called emissivity, is based upon the material that the object is made of and its surface finish.
15 MAINTENANCE Battery Replacement Power is supplied by four 1.5V (AAA size) batteries. The " " appears on the LCD display when replacement is needed. To replace the batteries, remove the screw from the back of the meter and lift off the battery cover case.
16 Substance Thermal Substance Thermal emissivity emissivity Asphalt 0.90 to 0.98 Cloth (black) 0.98 Concrete 0.94 Human skin 0.98 Cement 0.96 Lather 0.75 to 0.80 Sand 0.90 Charcoal (powder) 0.96 Earth 0.92 to 0.96 Lacquer 0.80 to 0.95 W ater 0.92 to 0.
.
WARRANTY OMEGA warrants this unit to be free of defects in materials and workmanship and to give satisf actory ser vice for a period of 13 months from date of purchase. OMEGA W arranty adds an additional one (1) month grace period to the nor mal one (1) year product warranty to cov er handling and shipping time .
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply . OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
Where Do I Find Everything I Need for Process Measurement and Control? OMEGA...Of Course! HEATERS þ Heating Cable þ Cartridge & Strip Heaters þ Immersion & Band Heaters þ Flexible Heaters .
デバイスOmega OS643-LSの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Omega OS643-LSをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはOmega OS643-LSの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Omega OS643-LSの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Omega OS643-LSで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Omega OS643-LSを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はOmega OS643-LSの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Omega OS643-LSに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちOmega OS643-LSデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。