http://www .omega.com e-mail: info@omega.com ® U ser ’ s Guide LV - 1 1 0 1 & LV - 1 1 0 2 Non-Magnet ic L iquid L evel Swi t ches.
WARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time.
Servicing Nor th America: USA: One Omega Drive, Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1 Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: canada@omega.
Unpacking Instructions Remove the Packing List and verify that you have received all equipment, including the following (quantities in parentheses): LV-1101 or LV-1102 level switch (1) Operator’s Manual (1) If you have any questions about the shipment, please call the OMEGA Customer Service Department.
General Description The OMEGA ® LV-1100 Series Liquid Level Switches feature a non-magnetic design suitable for application where magnetic particles (ie: rust) are present. The LV-1100 Series also feature rugged metal construction and a buoyancy adjustment to allow the unit to be used with fluids down to SP.
Specifications Working Fluid Specific Gravity Range: Adjustable between 0.6 and 1.0+ Nom. Working Pressure/Temperature: 300 PSIG @ 180˚F max. Liquid Level Change To Activate Switch: 1 / 4 inch Relay .
Installation The LV-1101 Series Level Switches are supplied with a 2" x 1" TT bushing threaded in place with 2 to 3 wraps of Teflon tape, which must be intact or renewed if bushing and switch are separated before assembly in tank. Apply a minimum of 2 to a maximum of 3 wraps of Teflon tape to the male threads of the bushing.
Check the match of the outside diameter of the cable with the inside diameter of the grommet. No more than .020" of play should be evident. NOTE 2.
Figure 1: Wiring Schematic for power applied to the load when the liquid level is LOWER than the set point (power to the load is interrupted when the liquid level is ABOVE the set point).
6.
Notes 7.
TEMPERA TURE Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies Wire: Thermocouple, RTD & Thermistor Calibrators & Ice Point References .
デバイスOmega Speaker Systems LV-1101の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Omega Speaker Systems LV-1101をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはOmega Speaker Systems LV-1101の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Omega Speaker Systems LV-1101の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Omega Speaker Systems LV-1101で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Omega Speaker Systems LV-1101を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はOmega Speaker Systems LV-1101の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Omega Speaker Systems LV-1101に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちOmega Speaker Systems LV-1101デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。