Instruction manual page 1 Gebrauchsanweisung Seite 23 Gebruiksaanwijzing pagina 45 Mode demploi page 67 Istruzioni per luso pagina 89 Instrucciones de uso pagina 1 1 1 Automatic Blood Pressure Monitor & Printer The World Hypertension League recommends regular blood pressure monitoring with clinically validated devices.
705CP-II English Dear Customer Contents Blood pressure monitor Important instructions to help you obtain meaningful readings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Y our blood pressure monitor: the benefits . . . . . . . .
2 705CP-II English The World Hypertension League recommends regular blood pressure monitoring by doctors and patients with clinically validated devices Regular blood pressure monitoring is essential for the prevention, the control and the management of hypertension.
3 705CP-II English ON/OFF (O/I) button ST ART ( ) button OMRON 705CP-II is a compact, fully automatic blood pressure monitor , operating on the oscillometric principle. It measures your blood pressure and pulse rate simply and quickly . It contains an intel ligent “fuzzy logic” system for controlled inflation, known as “Intellisense”.
4 705CP-II English Battery installation / replacement Slide the battery cover off in the direction of the arrow . Install or replace 4 “LR6” batteries so the + (positive) and – (negative) polarities match the polarities of the battery compartment as indicated.
5 705CP-II English How to set time and date Install the batteries and press the ON/OFF button. The display will show 0:00 Press and hold the SET button. The year digits (2002) will flash. Press the ADJUST button to advance the digit(s) one at a time.
6 705CP-II English How to apply the cuf f (when wrapping on your left arm) • Y ou can wrap the cuff either on your right or left arm. Insert air tube to air jack (on the left side of the divice). The cuf f must be airless. Remove tight-fitting clothing from your upper arm.
7 705CP-II English Pull the cuff so that the top and bottom edges are tightened evenly around your arm. When the cuff is positioned correctly , close the velcro fastener FIRML Y . Make certain the cuff fits snugly around your arm. The cuff should make good contact with your skin.
8 705CP-II English How to take a reading Press the (O/I) button. a) All display symbols appear for approximately one second. b) When the monitor becomes ready to measure, the ( ) symbol appears on the display . Press the (ST ART ) button and remain still.
9 705CP-II English START Continue to press button When the measurement is complete, the cuff completely deflates and your blood pressure and pulse rate are displayed. NOTE : The monitor automatically stores blood pressure and pulse rate into the memory .
10 705CP-II English How to use the memory function This monitor has a memory capable of storing 28 sets of readings. Every time you complete the measurement, the monitor automatically stores blood pressure and pulse rate. • T urn on the monitor by pressing the (O/I) button.
11 705CP-II English • Before measuring, stretch your back and sit up straight, breath normally 5-6 times, relax your shoulders, arms and entire body . • Slightly bend and support your elbow (e.g. on a table). • Do not move, talk or touch the device during measurement.
12 705CP-II English Failure, causes and rectification Failure and their possible causes Incorrect measurement is indicated by 1. A correct reading could not be obtained because measurement was disturbed by movement of the body . 2. The cuff is not fitted correctly .
13 705CP-II English Maintenance and storage • For cleaning the monitor only use a soft, lightly moistened cloth. Do not use petroleum spirits, thinners or similar solvents ! • Stains on the cuff can be carefully removed using a moist cloth and soapy water .
14 705CP-II English T echnical data This device fulfils the provisions of the EC directive 93/42/EEC (Medical Device Direc tive). This blood pressure monitor is designed according to the European stan.
15 705CP-II English OMRON spare parts Calibration The accuracy of this blood pressure monitor has been carefully tested and is designed for a long service life. It is generally recommended to have the monitor inspected every two years to ensure correct functioning and accuracy .
16 705CP-II English Some useful information about blood pressure What is Blood Pressure ? Blood pressure is a measure of the force of blood flowing against the walls of the arteries. Arterial blood pressure is constantly changing during the course of the hearts cycle.
17 705CP-II English What Causes High Blood Pressure ? Blood pressure is only classed as high if it doesnt go down when you rest. Permanently raised blood pressure can be caused by several factors such as hardening of the arteries, smoking or drinking too much alcohol.
18 705CP-II English Introduction The OMRON printer can be conected to OMRON blood pressure monitors with IT functions. Description Paper Feed Print Graph Print All Data Print Current Data/Stop Printin.
19 705CP-II English How to connect the printer unit Remove printer cable plug from the printer unit. Connect printer cable plug cord to the main unit. The circle on the cable plug should face up. Open printer cover in the direction indicated by the arrow symbol and remove paper roll from the main unit.
20 705CP-II English OMRON IT blood pressure monitors have the ability to print all the readings stored in memory . NOTE : • Make sure printer-unit is connected to main unit (see How to Connect Printer-Unit) • Do not use printer-unit without loading printer paper (see How to Load Printer Paper).
21 705CP-II English • Month(s) The month or months will be printed. Example: If the blood pressure reading was stored between months March-June, then the printout will indicate “3-6”.
22 705CP-II English T roubleshooting Error Indicator Cause Correction Printer cable plug is not connected properly or damaged Connect correctly reference p.
OMRON HEALTHCARE Co., Ltd. 53, Kunotsubo, Terado-cho, Muko, Kyoto, 617-0002 JAPAN OMRON HEALTHCARE EUROPE B.V. Scorpius 33, 2132 LR Hoofddorp, THE NETHERLANDS www.omron-healthcare.com OMRON (DALIAN) CO., LTD. Dalian, CHINA OMRON HEALTHCARE UK LTD. Opal Drive, Fox Milne, Milton Keynes, MK15 0DG, U.
デバイスOmron 705CP-IIの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Omron 705CP-IIをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはOmron 705CP-IIの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Omron 705CP-IIの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Omron 705CP-IIで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Omron 705CP-IIを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はOmron 705CP-IIの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Omron 705CP-IIに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちOmron 705CP-IIデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。