INSTRUCTION MANUAL MANUAL INFLA TION BLOOD PRESSURE MONITOR Model HEM-432C R.
2 T ABLE OF CONTENTS Introduction …………………………………………………………… 3 Important Safety Notes ……………………………………………… 4 Know Y our Uni.
3 INTRODUCTION Thank you for purchasing the Omron HEM-432C Manual Inflation Blood Pressure Monitor . Fill-in for future reference DA TE PURCHASED: ______________ SERIAL NUMBER: ________________ Staple your purchase receipt here. The monitor features an easy-to-squeeze inflation bulb that allo ws you to quickly inflate the cuff.
4 IMPORT ANT SAFETY NOTES To assur e the correct use of the pr oduct basic safety measures should always be followed including the pr ecautions listed below: Read all information in the instruction book and any other literature included in the box before using the unit.
5 KNOW YOUR UNIT Systolic Blood Pressure Display ON/Off Button Air Release Button Air Inflation Bulb Air Plug Air T ube (Connects to the air plug) Air T ube Arm Cuff Diastolic Blood Pressure / Pulse r.
6 QUICK REFERENCE GUIDE 1. Av oid eating, smoking, and exercising for at least 30 minutes before taking a measurement. 2. Put your left arm through the cuff loop. The bottom of the cuff should be about 1/2 inch abov e the elbow . The cuf f tab should lie ov er the brachial artery on the inside of the arm.
7 BA TTER Y INST ALLA TION / REPLACEMENT 1. Slide the battery cov er off in the direction of the arrow . 2. Install 4 “ AA” size batteries so + (positiv e) and – (negati ve) polarities match the polarities of the battery compartment as indicated.
8 CARE AND MAINTENANCE To k eep your digital blood pressur e monitor in the best condition and pr otect the unit fr om damage follow the dir ections listed below: Clean the monitor with a soft dry cloth. Do not use any abrasi ve or v olatile cleaners.
9 HOW TO APPL Y THE ARM CUFF 1. If the cuff is assembled correctly , the se wn hook material will be on the outside of the cuff loop and the metal D-ring will not touch your skin. 2. P ass the end of the cuff furthest from the tubing through the metal D-ring to form a loop.
10 HOW TO APPL Y THE ARM CUFF 4. Pull the cuff so that the top and bottom edges are tightened ev enly around your arm. 5. When the cuff is positioned correctly , press the sewn hook material FIRML Y against the pile side of the cuff. 6. Make certain the cuf f fits snugly around your arm.
11 HOW TO T AKE A MEASUREMENT Please read “How T o Apply The Arm Cuff” before taking a reading. 1. Press the ON/OFF Button. a) All display symbols appear for about one second. This is the initial LCD T est. b) The display symbols disappear and the Deflation Indication Symbol ( ) starts to flash.
12 HOW TO T AKE A MEASUREMENT 3. Remain still. The cuff will begin to deflate automatically . 4. As the cuff deflates, decreasing numbers appear on the display . The Heart Symbol ( ) flashes at ev ery heartbeat. 5. When measurement is complete, the Heart Symbol ( ) stops flashing and your blood pressure and pulse rate are displayed alternately .
13 HOW TO USE THE MEMOR Y FUNCTION This monitor has a memory capable of storing fourteen (14) sets of readings. E v ery time you complete the measurement, the monitor automatically stores blood pressure and pulse rate. • Press the ON/Off Button. • Press the MEMOR Y Button to recall stored readings while the Heart Symbol ( ) is displayed.
14 ERROR INDICA TORS Error Symbol Correction Cause Cuff under -inflated. Residual air pressure in cuff. Movement during Measurement No pulse or blood pressure reading due to very weak artery pulse. Cuff o ver-inflated (more than 300 mmHg). Batteries hav e run down.
15 FCC ST A TEMENT Note: PO TENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only) This product has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
16 W ARRANTY INFORMA TION Y our HEM-432C Manual Blood Pressure Monitor , excluding the monitor cuff, is w arranted to be free from defects in materials and workmanship appearing within 1 year , when used in accordance with the instructions provided with the monitor .
17 SPECIFICA TIONS Model: HEM-432C Display: LCD Digital Display Measurement Range: Pressure: 0 to 280 mmHg Pulse: 40-180/min. Accuracy/Calibration: Pressure: ±3mmHg or 2% of reading Pulse: ±5% of re.
18 NOTES.
19 NOTES.
Made in China Manufactured by: OMR ON HEAL THCARE, INC. 300 Lake view Parkw ay V ernon Hills, Illinois 60061 www .omronhealthcare.com Copyright © 2003 Omron Healthcare, Inc.
デバイスOmron Healthcare HEM-432Cの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Omron Healthcare HEM-432Cをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはOmron Healthcare HEM-432Cの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Omron Healthcare HEM-432Cの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Omron Healthcare HEM-432Cで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Omron Healthcare HEM-432Cを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はOmron Healthcare HEM-432Cの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Omron Healthcare HEM-432Cに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちOmron Healthcare HEM-432Cデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。