Instruction Manual Automatic Digital Bl oo d Pr es su re M on it or Model HEM-703CP HEM-703CP-xxxx 0692581-7 A.
1 Important CONTENTS I m p o r t a n t 1 Name and Function of Each Part 2 Preparations fo.
2 Name and Function of Each Part Air Jack Systolic Bood Pressure Display Diastolic Blood Pressure and Pulse Display Printing Paper Paper Cutter SPHYG/CLOCK Button ST ART Button PRINT / P APER FEED But.
3 Preparations for Use 1 How to insert the batteries Battery Cover 1 T ake off the battery cover at the back of the main unit by sliding it in the direction indicated by the arrow symbol Replace.
4 Preparations for Use 2 How to Set T ime and Date 3 Plug in and T urn on 1 When batteries are installed, the display shows PM 12:00 1 Insert the air plug into the air jack on the left side o.
5 Preparations for Use 4 How to Set the Printing Paper Please be sure not to print without inserting printing paper as it will shorten the life span of the printer head 1 Slide the plastic print.
6 Preparations for Use 5 Changing the Printer Ink Though not originally equipped with an ink roller , the HEM-703CP digital blood pressure monitor contains enough printer ink to last about two years w.
7 about 1 inch Artery no space Preparations for Use 6 Attach the Cuf f This cuff has eliminated the need for a microphone thereby lessening possible interference from vibrations and noise Fitting a.
8 Preparations for Use 7 Apply Pressure to the Cuf f 1 When you press the start button, the pump operates and pressure is applied When the pressure reaches 170mmHg, the pump stops automatically .
9 Measurement Completed Alternate Display Blood Pressure Reading Display (for approx 3 seconds) Pulse Reading Display (for approx 15 seconds) *P: Stands for PULSE Preparations for Use 8 Bl.
10 When Error Indication Symbols Appear The following special error symbols will appear in the display if the unit is being used incorrectly: ERROR SYMBOL CAUSE CORRECTION 1 Cuff underinated 1) .
1 1 Specications Power Source: Battery (four type “AA” dry cell batteries) 6V 4W Measurement Method: Oscillometric Method Display: Liquid Crystal Digital Display Measurement Range: Pressure: 0 .
12 This equipment generates and used radio frequency energy and if not installed and used properly , that is, in strict accordance with the manufacturer’s instructions, may cause interference to rad.
13 Limited One Y ear W arranty YOUR OMRON MODEL HEM-713C Digital Blood Pressure Monitor is warranted to be free from manufacturing defects for a period of one year under normal use This warranty ex.
デバイスOmron Healthcare HEM-703CPの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Omron Healthcare HEM-703CPをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはOmron Healthcare HEM-703CPの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Omron Healthcare HEM-703CPの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Omron Healthcare HEM-703CPで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Omron Healthcare HEM-703CPを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はOmron Healthcare HEM-703CPの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Omron Healthcare HEM-703CPに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちOmron Healthcare HEM-703CPデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。