Omron HealthcareメーカーHEM-CR24の使用説明書/サービス説明書
ページ先へ移動 of 27
Check following components! Vérifier les composants suivants ! Prüfen Sie folgende T eile des Lieferumfangs! Controllare i componenti indicati di seguito! ¡Compruebe los siguientes componentes! Controleer de volgende onderdelen! Проверь те следующие ко мпоненты! HEM-721 1-E_B_M02_100928.
Content s Thank you for purchasing the OMRON M6 Au tomatic Blood Pressure Monitor . The OMRON M6 is a compact, fu lly automatic blood pressur e monitor , operating on the oscillometric principle. It measures your blood pressure and pulse rate simply and quickly .
1 EN Import ant Safety In formation Consult your doctor prior to using in pregnancy or if diagnosed with arrhyt hmia or arteriosclerosis. Please read t his section carefully b efore using the unit. War ni n g: • Indicates a pot entially hazardous situation which, if not avoided, could re sult in death or seriou s injury .
2 Impor tant Safet y Inform ation (AC Adapter Usage) • Use only the original AC adapter (optional) designed f or this unit. Use of unsupported adapters may damage and/or may be hazardous to the unit. • Plug the AC adapter into the appropriate voltage outlet.
3 EN 1. Overview Main unit Display Memory button O/I ST ART ( ) button Up/Down ( ) buttons Date/T ime setting ( ) button Air Jack Battery compartment AC adapter jack (for optiona l AC adapter) Arm cuf.
4 2. Prep aration 2.1 Inst alli ng/Replaci ng the Batteries 1. Remove the battery cover . 2. Insert four “AA” batteries as indicated in the battery comp artment and then replace the battery cover . Not es: • If the ba ttery low symb ol ( ) appea rs on the display , turn the unit of f then replace all bat teries at the same time.
5 2. Prep arat ion EN 2.2 Setting the Date and T ime 1. Pr ess th e butt on. 2. Set the monitor to t he correct date and t ime before t aking a measureme nt for the first time. 3. Press the O/I ST ART button to store the setting. Not es: • If the batteries have been removed for 30 seco nds or more, the date and time setting will need to be reset.
6 3. Using the Unit 3.1 Appl ying the Arm Cuff Remo ve tight-fi tting clo thing or tigh t rolled up sleeve f rom your u pper arm. Do no t place the c uff over thic k cloth es. 1. Insert the air plug into t he air j ack . 2. Put your arm through the cuff loop .
7 3. Using the Unit EN 3.2 How to Sit Correctly T o take a meas urement , you need to b e relaxed a nd comfor tably seated, u nder comfor table room temp erature. No b athing, dr inking alcohol or caffeine, smoki ng, exerci sing or eati ng 30 min utes befor e taking a meas urement.
8 3. Using the Unit 3.3 T aki ng a Readin g Not es: • T o cancel a mea surem ent, pr ess th e O/I ST ART b utton to turn the uni t of f and to rel ease t he air i n the arm cuf f. • Remain still while taking a measurement. 1. Press t he O/I ST ART button.
9 3. Using the Unit EN Dual Check System Press the O/I ST ART button, then the Dual Check System lamp lights and the unit sta rts detecting a device error . If the unit is accurate and functioning correctly , the Du al Check System lamp remains lit dur ing the meas urement.
10 3. Using the Unit • Y our blood pr essure monitor includes an irregular heartbeat feature. Irregular heartbeats can influence the results of t he measur ement. The irregular heartbeat algorithm automatically determines if the m easurement is usable or needs to be repeat ed.
11 3. Using the Unit EN 3.4 Using the Memo ry Func tion The m onitor automa tically s tores the r esult up to 9 0 sets. It can also ca lculate an avera ge reading b ased on th e measurem ents from the las t three rea dings taken within 10 minutes .
12 3. Using the Unit T o V iew the Rea dings S tored in Memory 1. Press the button, while the aver age value is dis played. The M emory numbe r appears for a secon d before the pulse rate is di splayed . The newe st set i s numb ered “1” . 2. Press the or button to view the readings stored in memory .
13 EN 4. T roubl eshooting and Maintenance 4.1 The Ico ns and Error Mes sages Error Display Cause Remedy Irregular heartbeats are detected. Remove the arm cuff. W ait 2-3 minutes and then t ake another measureme nt. Repeat the steps in section 3.3. If this error continues to appear , contact your doctor .
14 4. Troub leshoot ing a nd Maint enance Air plug disconnected. Insert the plug securely . Refer to section 3. 1. Arm cuff not app lied correctly . Apply the arm cuff correctly . Refer to section 3. 1. Air is leaking from the arm cuff . Replace the cuf f with the new one.
15 4. Troub leshoot ing a nd Maint enance EN 4.2 T roubles hooting Problem Cause Remedy The reading is extremely low (or high). Arm cuff not applied correctly . Apply the arm cuff correctly . Refer to section 3.1. Movement or talking during measurement.
16 4. Troub leshoot ing a nd Maint enance Nothing happens when you pres s the buttons. The batteries are empty . Replace the batteries with new ones. Refer to section 2.1. The batteries have been inserted incorrectly . Insert the batteries wi th the corr ect (+/-) polarity .
17 4. Troub leshoot ing a nd Maint enance EN 4.3 Maintenance T o protec t your uni t from damage , please o bserve the following: • Do not subject the main unit and the cuf f to extreme te mperatures, humidity , moisture or direct sunlight. • Do not fold the cuff or tubing tightly .
18 4. Troub leshoot ing a nd Maint enance 4.4 St or a ge Keep th e unit in i ts storage ca se when no t in use. 1. Unplug th e air plu g from the air j ack. 2. Gently fold the air tube into the arm cuff. Not e: Do not bend the air tube excessively . 3.
19 EN 5. Optional Part s Using th e Optional AC Adapter 1. Insert the AC ada pter plug into the AC adapter jack on the rear s ide of the main unit . 2. Plug the AC adapter into an electrical outlet. T o disc onnect the AC adapter , unplu g the AC ada pter from th e electric al outlet first and then remove the AC adap ter plug from the main unit.
20 6. T echnical Dat a Note: Subject to technical modification without prior noti ce. Pro duct D escr iptio n Autom atic Blood Pressure Monitor Model O MRON M6 (HEM -721 1-E / HEM-72 1 1-E8) Display LCD Digital Display Meas urement Method Oscillometric me thod Measure ment R ange Pres sure : 0 to 299 m mHg Puls e: 40 to 1 80/min.
21 6. Techni cal Data EN • This dev ice ful fils the p rovision s of EC di rectiv e 93/42/EE C (Medic al Device Directi ve). • This bloo d pressure monitor is des igned accordi ng to the Euro pean.
22 6. Techni cal Data Import ant in formation re garding Electro Magnetic Com p atibility (EM C) With the increased num ber of electronic devices such as PC’s and m obile (cellular) telephones, medical devic es in use may be suscep tible to electromagnetic interference from other devices.
23 EN 7. Some Useful In formati on about Bl ood Pressur e What is Blood Pressure? Blood pres sure is a measure of the forc e of blood flowing ag ainst the walls of t he arteries. Arterial blood pres sure is c onstantly chan ging durin g the cours e of the hea rt’s cycle.
24 7. Some Useful In formation a bout B lood Pre ssure Why is it a Good Thing to me asure Blood Pressure at Home? Many fac tors such as phys ical acti vity , anxiety , or the time of day , ca n influ ence your blood pr essure. A singl e measur ement may not be sufficient for an accu rate diagnos is.
25 7. Some Useful In formation a bout B lood Pre ssure EN Classification of Blood P ressure by the Wo rld Health Organiza tion The World Hea lth Organi zation ( WHO) and th e Internati onal So ciety o f Hype rtensio n (ISH) d eveloped the Bloo d Pressure C lassificatio n shown in thi s figure.
デバイスOmron Healthcare HEM-CR24の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Omron Healthcare HEM-CR24をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはOmron Healthcare HEM-CR24の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Omron Healthcare HEM-CR24の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Omron Healthcare HEM-CR24で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Omron Healthcare HEM-CR24を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はOmron Healthcare HEM-CR24の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Omron Healthcare HEM-CR24に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちOmron Healthcare HEM-CR24デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。