IM-HEM-7321-E-01-08/2013 English Français Deutsch Italiano Español Nederlands Ɋɭ ɫɫɤɢɣ Türkçe 2298869-1A Automatic Blood Pressure Monitor Model M6 Comfort Instruction Manual.
1 2 b c d b a J N O.
P S R Q T Z W V X Y AA A M N D F E J G K H L AF AE AD H AB O H G I B C U H AC.
Vérifier les composants suivants ! Prüfen Sie folgende T eile des Lieferumfangs! Controllare i componenti indicati di seguito! $úD÷ÕGDNLELOHúHQOHULNRQWUROHGLQ ¡Compruebe los siguien.
Contents Thank you for purchasing the OMRON M6 Comfort Automatic Blood Pressure Monitor . The OMRON M6 Comfort is a compact, fully automatic blood pressure monitor , operating on the oscillometric principle. It measures your blood pressure and pulse rate simply and quickly .
1 EN Import ant Safety Info rmation Warnin g: Indi cat e s a p ot ent ial ly ha za rd ous s it u a t i on whi ch , if n ot av o ide d , c o uld res u lt in de at h o r seri ous in jury . (General Usage) Consult your physician before using the device in pregnancy including pre-eclampsia, or if diagnosed with arrhythmia or arteriosclerosis.
2 Impor tant Safety Informatio n If there are any abnormalities during the measurement, remove the arm cuff. Do not use this device on i nfants or persons who cannot express their intentions. Do not inflate the arm cuff more than necessary . Do not use the device for any purpose other t han measuring blood pressure.
3 Impor tant Safety Informatio n EN (Battery Usage) Do not insert the batteries with their pol arities incorrectly aligned. Use only 4 “AA” alkaline or manganese batteries with this devi ce. Do not use other types of batteries. Do not use new and used bat teries together .
4 1. Know Y our Device Monitor Display Cuff wrap guide lamp Memory butt on Weekly average button ST ART/ST OP butto n Up/Down buttons USE R ID se le c tio n sw it ch Date/T ime setting button Blood pr.
5 1. Know Your De vice EN Display Symbols Irregular Heartbea t Symbol ( ) When the monit or detects an irregular rh ythm two or more times during t he measurement, t he irregular heartbeat s ymbol ( ) will appear on the display with the measurement values.
6 1. Know Your De vice Blood Pressure Colour Indicator If your systolic or diastolic pressure is above the standard range (135 mmHg for the systolic blood pr essure and/or 85 mmHg for t he diastolic blood pres sure), the blood pressure colour indicator will light in “orange” when the measurem ent result is displayed .
7 EN 2. Prep aration 2.1 Battery Inst allation 1. Remove the battery cover . 2. Insert 4 “AA” batteries as indicated in the battery comp artment. 3. Replace the battery cover . Not es: • When the low battery sy mbol ( ) appears on the display , turn the monito r off, then replace all batteries at the same time.
8 2. Prep aratio n 2.2 Setting the Date and T i me Set th e m o n itor to the co rrec t d a te a nd tim e b e fore t akin g a m e asure me nt for th e first time. 1. Press the Date/T ime setting ( ) button . The year flashes o n the Date/Time displ ay .
9 EN 3. Using the Device 3.1 Appl ying th e Arm Cuff Remo ve tight- fitting c lothing o r tight r olled up sleeve f rom your l eft upper arm. Do no t place th e arm cu ff over thick c lothes. 1. Insert the air plug in to th e a ir jac k securely . 2. Apply the arm cuff to your left upper arm.
10 3. Using the Device 3.2 How to Sit Correctly T o take a meas urement , you need to be rel axed and c omfortably seated, u nder comfor table room t emperature. Avoid bathin g, drink ing alco hol or c affeine, smok ing, exerci sing or eating 30 minutes before taking a meas urement.
11 3. Using the Device EN 3.3 T aking a Measurement Not es: • T o cancel a measureme nt , press the ST ART /ST OP bu tton t o release th e air in th e arm cuf f.
12 3. Using the Device 3. Remove the arm cuff. 4. Press the ST ART/STOP but ton to turn the monitor off. The m onitor au tomatical ly stores the me asurement r esult i n its memory . It will automat ically turn off after 2 minut es. Note: W ait 2-3 minutes before taking another measurement.
13 3. Using the Device EN 3.4 Using the Memo ry Function The m onitor au tomatical ly stores the resul ts up to 100 se ts for each user (1 an d 2). It can als o calc ulate an averag e value base d on the las t 3 m easurem ent valu es taken within 10 minu tes .
14 3. Using the Device T o V iew the Ave rage V a lue 1. Select your US ER ID (1 or 2). 2. Press and hold the button for mo re than 3 seconds. Not es: • If the previous measurement was taken without setting the date and t ime, the average value is not calculated.
15 3. Using the Device EN T o V iew the W eekly Average V alue The m onitor c alculate s and dis plays weekly a verages for the m easurem ents taken in the m orning and e vening wi thin 8 wee ks for e ach user . Note: The week begins Sunday at 2 :00. 1.
16 3. Using the Device Note: If there are no measurement values stored in the memor y , th e screen to the r ight is displayed. Morning W eekly A verage This is the av erage for the measurements taken during t he morning (4:00 - 1 1:59) between Sun day and Saturday .
17 3. Using the Device EN T o Delete All the V alues S tored in Memory The val ues stor ed in the m emor y are delete d by U SER ID. 1. Select your US ER ID (1 or 2). 2. Press the Memory button, while the memory symbol ( ) appears. 3. Whil e holding the button down, press the ST ART/STOP button for more than 3 se conds.
18 4. Error Messages and T roub leshooting 4.1 Error Mess ages Display Cause Solution Irregular heartbeats are detected. Remove the arm cuff. W ait 2-3 minutes and then t ake another measureme nt. Repeat the steps in section 3.3. I f this error continues to appear , contact your physician.
19 4. Error Message s and Troubleshoo ting EN Air plug is disconnected. Inse rt the air plug securely . Refer to section 3.1. Arm cuff is applied too loos ely . Apply the arm cuff tighter . Refer to section 3.1. Air is leaking from the arm cuff . Replace the arm cuff wit h a new one.
20 4. Error Message s and Troubleshoo ting 4.2 T roubles hooting Proble m Cause S olutio n The measurement resu lt is extremely high (or low). Arm cuff is applied t oo loosely . Apply the arm cuff tighter . Refer to section 3.1 . Movement or talking during measurement.
21 4. Error Message s and Troubleshoo ting EN Nothing happens when you pres s the buttons. The batteries are empty . Replace the batteries with new ones. Refer to section 2.1 . The batteries have been inserted incorrectly . Insert t he batt eries with t he correc t (+/-) polarity .
22 5. Maintenance and S torage 5.1 Maintenance T o protec t your dev ice fro m damage, p lease obs erve th e followi ng: • S t ore the de vice and the c omponents in a clean, safe location. • Do not use any abr asive or volatile cle aners. • Do not wash the device and any components or immerse them in water .
23 5. Mai ntenance and Stor age EN 5.2 St or a g e Keep th e device in its s torage c ase when n ot in use. 1. Unplug the air plug fr om the air jack. 2. Gently fold the air tube into the arm cuff. Note: Do not bend or crease the air tube excess ively .
24 5. Mai ntenance and Stor age 5.3 Optional Medical Accessories (withi n the sc ope of EC Medical De vice Direct ive 93/42/E EC) Arm c uff Arm cir cumferenc e 22-42 c m AC a d a pter Intelli Cuf f L-.
25 5. Mai ntenance and Stor age EN Using the Optional AC A dapter 1. Insert the AC ada pter plug into the AC adapter jack on the rear side of the monitor .
26 6. S pecifications Prod uct des cript ion Automatic B lood Pre ssure Mon itor Model OM RON M6 Comfort (HEM-7321-E) Display LCD digi tal dis play Meas ure ment me th od Oscillometric method Meas ure ment ra ng e Pre ssure: 0 to 299 mm Hg Pulse: 40 to 180 be ats / min.
27 6. Sp ecificat ions EN Not es: • These s pecifications are subject t o change without not ice. • In the clinical validation st udy , the 5t h phase was used on 85 subject s for determination of diastolic blood pressure. • This device has not been validated f or use on pregnant patients.
28 6. Sp ecificat ions Import ant informa tion regarding Ele ctro Magneti c Compati bility (EMC) With the increased number of electronic dev ices such as PC’s and mobile (cellular) t elephones, medical devic es in use may be suscep tible to electromagnetic interference from ot her devices.
29 EN 7. Wa r r a n t y Thank you for buying an OMRON product. This product is constructed of high quality materials and great care has been taken in its manufacturing. It is designed to give you every satisfaction, prov ided that it is properly operated and maintained as described in the instruction manual.
30 8. Som e Useful Inform a tio n a bout Bloo d Press ure What is Blood Pressure? Blood pres sure i s a meas ure of the force of blood flowing against the wall s of the a rteries . Arterial blood pr essure is constantly changi ng durin g the cour se of the heart’s cycle.
Manufacturer EU-representative OMRON HEAL THCARE EUROPE B.V . Scorpius 33, 2132 LR Hoofddorp, THE NETHERLANDS www .omron-healthcare.com Production facility Üretim T esisi Site de production Produktio.
デバイスOmron M6 Comfortの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Omron M6 Comfortをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはOmron M6 Comfortの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Omron M6 Comfortの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Omron M6 Comfortで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Omron M6 Comfortを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はOmron M6 Comfortの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Omron M6 Comfortに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちOmron M6 Comfortデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。