Fully Integrated Sequence and Loop Control New Built-in Loop Controller CJ 1 G-CPU P Loop-control CPU Unit Unit Version 3.5 (Version Upgrade) CJ1 Special I/O Units Process Analog Input Units (Isolated.
3 Introducing the New Style of Loop Control Advanced controller functions integrated with the same CJ-series functionality and high-speed capabilities Duct Duct 90 mm high S82K G3J J7AN Power supply S.
5 New Algorithm Further Enhances Control Stability Disturbance Overshoot Adjustment Optimum Tuning to Suit the Application Fine Tuning Disturbance Disturbance generated Time required to stabilize Over.
Sterilization and Disinfection of Pharmaceuticals, Food and Beverages Loop-control CPU Unit Loop-control CPU Unit N 2 atmosphere Solder Workpiece Conveyor NS-series PT NS-series PT Heater Temperature .
7 Process Loop Control Machines and Product Variations High-speed and highly reliable (duplex) Easy Controlling analog quantities CS1D-series Process-control CPU Unit (See note 2.
8 Peripheral Devices Input Devices Input Devices Output Devices Output Devices E52-series Temperature Controllers ES1/ES1B-series Infrared Thermosensors G3PF Solid-state Relay with Built-in Current Transformer (CT) Model Structure Example: E52-CA15A D:3.
9 New Products CJ1W-AD04U Process Analog I/O Unit (General-purpose Unit with Fully Universal Inputs) CJ1W-PH41U Process Analog I/O Unit (High-resolution Unit with Fully Universal Inputs) Fully Univers.
10 Loop-control CPU Unit s Loop-co ntrol CPU Units Loop-control CPU Units Loop- control C PU Un its Loop Contro ller Element Specifications Model CPU Unit element Loop Controller I/O capacity Program .
11 Loop-control CPU Units Loop C ontroller Element S pecificati ons Loop Con troller Elemen t Specificati ons Item Specifications Model CJ1G-CPU42P CJ1G-CPU43 /44/45P(-GTC) Operation method Function b.
12 List of Functio n Blocks System C ommon B lock List of Function Blocks System Common Block Control Blo cks Note: 1. The Function Bloc ks dealing with high-speed operation (operation cycle: 0.01, 0.02, and 0. 05 seconds is possible). 2. Cannot be used with the CJ1G-CPU45P-GTC .
13 List of Fu nction Blocks Note: 1. The Function Blocks dealing with high-speed operation (operation cycle: 0.01, 0.02, and 0.05 seconds is possible). 2. Cannot be us ed with the CJ1G-CP U45P-GTC. Sequence Contro l Note: The Function Blocks dealing with high-speed operation (oper- ation cycle: 0.
14 CX-Pr ocess T ool and Monitor Soft wa re S pec ific atio ns CX-Process Tool and Monitor Software Specifications Item Specifications CX-Process T o ol CX-Process Monitor Plus Name CX-Process CX-Proc.
15 CX-Pr ocess T ool and Monitor Conne ctions t o PLC Note: The CX-Process f unctions that can be used depend on the version. F or det ails, ref er t o the operation man uals (Cat. No .: W372-E1- @ and W373-E1- @ ). Note: 1. When using Windows Me, the CPU must be a P entium 150 MHz or higher .
16 Utility S o ftwar e T ouch P anel S oftware Utility Software Touch Panel So ftwar e ■ Face Plat e Auto-Buil der for NS Simply specify the CSV tag file created using the CX-Process T ool to automatically create a project constructed with a F ace Pla te for Loop-control CPU Units for use with OMRON's NS-series Programmable T er minals.
17 Dimensions C PU Units Dimensions CPU Units ■ Loop-control CPU Units CJ1G-CPU42 P CJ1G-CPU43 P CJ1G-CPU44 P CJ1G-CPU45P(-GT C) ■ Process Input Units CJ1W -P @@@@ CONTROLLER CJ1G-CPU44P SYSMAC PROGRAMMABLE ERR/ALM RUN COMM INH PRPHL OPEN PERIPHERAL BUSY MCPWR PORT 65 69 73.
18 Ordering Inf ormation Basic C onfi gur atio n Units Ordering Information Basic Config uration Units ■ CJ1 Loop Control Units ■ CJ1 CPU Units Produc t name Specifi cati ons Curre nt consump tion.
19 Ordering Information Basic Configu ration Units Note: 1. Current consumptions include current fo r a Progr amming Console. Add 0.15 A per Adapter when using NT -AL001 RS-232C/ RS-422A Adapters. Add 0.04 A per Adapter when using CJ1W -CIF11 RS-422A Adapters.
20 Ordering Inf ormation Basic Con figuration Units ■ CJ1 CPU Units (w ith Built-in I/O) Note: 1. Current consumptions include current f or a Programming Cons ole. Add 0.15 A per Adapter when using NT -AL001 RS-232C/RS-422A Adapters. Add 0.04 A per Adapter whe n using CJ1W-CIF11 RS-422A Adapters.
21 Ordering Information Basic Configu ration Units ■ Power Supply Units One P ower Supply Unit is required f or each Rack. Pr oduct name P ower sup pl y vol t a g e Output capacity Options Model Sta.
22 Ordering Inf ormation Basic Con figuration Units ■ Connector Cables for Bu ilt-in I/O in CJ1M-CPU @ 2 CPU Unit The connector for b uilt-in I/O in the CJ1M-CPU21/22/23 is not included. Purchase one of the connectors or connector cables in the follo wing table separately .
23 Ordering Information Basic Configu ration Units Connection t o Servo Driver with Bu ilt-in I/O When t wo axes are u sed, two C onnec ting Cables a re requir ed at th e Ser vo Driver for each Servo .
24 Ordering Inf ormation Programming Devices Programming Devices Note: Site licenses are als o av ailable for users that nee d to use th e CX -One on many co mputers. Ask your OMRON representa tiv e for det ails . When purchas ing the D VD format, verify the computer mode l and D VD drive specific ations bef ore purchasing.
25 Ordering Information Basic I /O Unit s Basic I/O U nits ■ Input Units Note: Connectors are not provided wit h these connector models. Eit her pur chase one of the following 40-pin connectors, or use an OMRO N XW2 @ Connector-T erm inal Block Conv e rsion Unit or a G7 @ I/O Rela y T er minal.
26 Ordering Inf ormation Bas ic I /O Uni ts ■ Output Units Note: Connectors are not provided with these connector m odels. Either purchase one of t he foll ow ing 40-pin connectors, or use an O MRO N XW2 @ Connector-T erm inal Block Conv ersion Unit or a G 7 @ I/O Rela y T erminal.
27 Ordering Information Basic I /O Unit s ■ I/O Units Note: 1. Connectors are not provided with these connector models. Either purchase one of the f ollowing 40-pin Connectors, or use an OMRO N XW2 @ Connector-T er minal Block Conv ers ion Unit or a G7 @ I/O Relay T er minal.
28 Ordering Inf ormation Specia l I/O Unit s Special I/O Units ■ Process I/O Units Isolated- type Units with Fully Universal Inputs Note: 1. Do not connect a Relay Contact Output Unit in the same C PU Ra ck or Expansion Rack as the CJ1W-PH41U Isolated-type Universal Input Unit.
29 Ordering Information Special I/O Un its Isolated-type Thermocouple Input Units Note: 1. The accuracy depends on the sensors used and the measurement te mperatures. F or details, refer to the user’ s manual. 2. This is for an external power supply , and not f or internal current consum ption.
30 Ordering Inf ormation Specia l I/ O Uni ts ■ Analog I/O Uni ts Analog Input Units Note: 1. The resolution and conversion speed cannot be set independently . If the resolut ion is set to 1/4,000, then the conversion speed wil l be 1 ms/point. 2. At 23 ± 2 ° C 3.
31 Ordering Information T emperature C ontrol Uni t Analog I/O Units Note: The resolution and conversion speed cannot be set independently . If t he resolution is set to 1/4,000, then the conversion speed will be 1 ms/ point.
32 Ordering Inf ormation CPU Bus Units CPU Bus Units ■ Controller Link Units Controller Link Units, Ne w Models Controller Link Units, Old Models New models are fully compatible wi th old models and provide enhanc ed functionality , such as an increase in the number of send w ords from 1,000 to 4,000 words.
33 Ordering Information Seri al Communicati ons Units Serial Communi cations Units Note: 1. The Serial Gatewa y function is enabled onl y for Serial Communications Units of unit v ersion 1.2 and later . 2. The no-protocol function is enabled only f or Serial Communications Units of unit version 1.
34 Ordering Inf ormation D e viceNet Un it DeviceNet Unit CompoNe t Master Unit CompoBu s/S Master Unit Unit classi- fica- tion Pr oduct name Specifi cation s Commun ications type No.
35 Ordering Information ID Sensor Un its ID Sensor Units Note: 1. T o use a V680-H01 Antenna, refer to the V680 Series RFID S ystem Catalog (Cat. No . Q151). 2. Specifications subject to change without notice. SYSMAC SPU (High-speed Data Storage Unit) Unit classi- fica- tion Pr oduct nam e Specifications No.
36 Ordering Inf ormation NS-ser ies Pr ogrammable T er minals NS-series Programmable T erminals ■ NS-Runtime Note: A hardware key (USB dongle) is required to run NS-Runtime. Model name Specifications Model number Standards Ethernet Case col or NS5-V2 5.
37 Ordering Information Orde ring Infor matio n Ordering Information International Standards • The standards indicated in the “Standards” column a re those cur- rent for UL, CSA, cU Lus, cUL, NK, and Lloyd standards and E C Directives as of the end of Jan uar y 2008.
Note: Do not use this document to operate the Unit. Printed in Japan 0308(1104) Authorized Distributor: In the interest of product improvement, specifications are subject to change without notice. Read and Understand this Catalog Please read and understand this catalog before purchasing the product.
デバイスOmron Smart Process Control CJ-Seriesの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Omron Smart Process Control CJ-Seriesをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはOmron Smart Process Control CJ-Seriesの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Omron Smart Process Control CJ-Seriesの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Omron Smart Process Control CJ-Seriesで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Omron Smart Process Control CJ-Seriesを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はOmron Smart Process Control CJ-Seriesの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Omron Smart Process Control CJ-Seriesに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちOmron Smart Process Control CJ-Seriesデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。