User’s Manual LPN5627, LPR5627 (Raster) Miniature High Speed Laser Fixed Position Scanner Manual No. 25-ULPNR101-03 February, 2003 8 Olympic Drive Orangeburg, NY 10962 Tel 845.
.
Contents Section 1 Introduction and Getting Started 1 Product Overview 1 Quick Start-Up Procedure 1 Section 2 Technical Specifications 2 Physical Specifications 2 Symbologies Supported 2 Optical Speci.
Organization of this Manual This manual provides the necessary instructions for installing and using the Opticon LPN5627 and LPR5627 Fixed Position Scanners. The manual is organized as follows: Section 1 Introduction and Getting Started Describes the general operation of the LPN 5627 and LPR5627 scanners.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 1 Section 1 Introduction and Getting Started Product Overview The LPN5627 and LPR5627 (Raster) Fixed Position Sca nners are miniature, 500 scan per second, laser bar code readers designed to be easily incorporated in to host equipment.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 2 This Quick Start-Up procedure will get you started. However, to best understand the full capabilities of this scanner, you should read the complete manual. Section 2 Technical Specifications Physical Specifications Case Material Zinc-die cast Dimensions 1.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 3 Pitch Recommended operation ( α ) at + 60 degrees or less Avoid specular reflection in the dead zone (hatched).
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 4 Curvature LPR5627 Raster Pattern Raster sweep pattern as seen from front of scanner Subtends a 1 ° angle from top to bottom of raster (at th e centerline) as measured from the scanner.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 5 Electrical Specifications Operating Voltage +5VDC + 10% Current Operating 150mA idle; 350 mA max. (Laser ON) Surge 2.5 A max. RS232 Communications Specifications RS232 Data Transmission Format Parameter Default Optional Settings Timing Asynchronous No.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 6 Environmental Specifications Temperature Operating +32 to +113 ° F (0 ° to +45 ° C ) Storage +14 to +140 ° F.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 7 Section 3 Positioning the Scanner Achieving Optimum Performance Three items greatly impact performance: 1) Dista.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 8 Readable Bar Code Width LPN5627/LPR5627 (Field-of-View Specification Based Upon 40 Degree Sweep) Distance from Window Max. Width 2.0” 2.0” 4.0” 3.5” 8.0” 6.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 9 3) Quality Bar Code Labels The quality of the bar code label can affect the sca nning performance. Poor quality labels are more difficult to decode and may result in non-reads or potential misreads.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 10 The scanner will read the barcode continuously and will display the ratio of the number of successful reads to the total number of attempts. The printout on the screen will appear as follows: (Example) 700d OK 93.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 11 Application Notes Tips for Achieving High Throughput In some applications your primary objective may be to achieve the highest possible throughput rate.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 12 Tips for Verifying the Presence of a Bar Code If the scanner is operated in the “trigger enabled” mode and the trigger is activated, one of three conditions may occur: A bar code is scanned and decoded.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 13 Section 4 Configuring the Scanner Since the operation of the LPN5627 / LPR5627 scanners are microprocessor controlled, it is possible to modify or program its operation to match your specific application.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 14 Section 5 Application Engineering Support Technical Assistance and Support Opticon is eager to help you integrate the LPN5627 / LPR5627 scanner into your application.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 15 Section 6 Scanner Labeling CDRH Class II Laser Device LPN5627 / LPR5627 scanners comply with Center for Devic es and Radiological Health (CDRH) regulations 21, CFR Subchapter J.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 16 Appendencies Appendix A How to Program the Scanner Appendix B Computer Programming Commands Appendix C Bar Code.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 17 Appendix A Programming the Scanner Two different methods can be used to prog ram parameters to configure the scanner: a.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 18 change only a few parameters at one time. We reco mmend that you keep a record of the changes you have made to the scanner. What if you make a mistake? Don’t worry.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 19 Appendix B Computer Programming Commands All commands must be preceded by an 'ESC' character and be followed by a 'Carriage Return' character.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 20 Enable Disable Options for Codabar (NW-7) 7K 7L Enable 1 character read F0 Do not transmit start/stop character.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 21 Communications Parameters K1 300 baud K2 600 baud K3 1,200 baud K4 2,400 baud K5 4,800 baud K6 9,600 baud K7 19.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 22 T3 Volume = Minimum V5 Ring buzzer once at 3kHz for 200 mS V6 Ring buzzer at 3kHz & 2kHz for 200 mS V7 Ring buzzer at 2kHz & 3kHz for 200 mS W0 Disable Buzzer W1 Enable buzzer at 3kHz W2 Enable buzzer at 3kHz with 2.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 23 X7 Xmit data from Low and High gain Good Read LED Operation T4 Disable good read LED (GRL) T8 GRL ON for 0.10 seconds after decode T5 GRL ON for 0.20 seconds after decode T6 GRL ON for 0.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 24 Appendix C: Bar Code Programming Menus & Commands Index 1. Global Default & Sc anner Config uratio ns....................................... 25 2. Symbology Selectio n .
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 25 1. Global Default & Scanner Configurations Computer Command Function /Description Bar Code Command (Z7) STA.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 26 1. Global Default & Scanner Configurations (continued) Computer Command Function /Description Bar Code Comm.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 27 ♦ Good LED after decoding (green, 200 ms). ♦ RS232C (9600 baud, 8, 1, no parity, no handshaking). Read Rate Mode (U8) - This mode resets all unit parameters to a predefined set of defaults for the purpose of checking the scanner read rate.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 28 2. Symbology Selection Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu .
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 29 2. Symbology Selection (continued) Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu -[8- J6 Only EAN +5 -K7- J7 Only Industrial 2 of 5 -K8- J8 Only Interleaved 2 of 5 -K9- Z9 Remote Menu -[:- 3.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 30 3. Add/Activate Specific Bar Code Symbologies (continued) Computer Command Function /Description Bar Code Comma.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 31 4. Delete/Deactivate Specific Bar Code Symbologies Computer Command Function /Description Bar Code Command (Z7).
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 32 4. Delete/Deactivate Specific Bar Code Symbologies (continued) Computer Command Function /Description Bar Code .
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 33 6. Options for Code 39 Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu .
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 34 7. Options for Codabar (NW-7) Computer Command Function /Description Bar Code Command (Z7) START/END Programmin.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 35 Codabar (NW-7) Format Start Character 1 to 42 data digits Check digit Stop Character A . . . . . . . . T a . . . . . . . . t A . . . . . . . . A a . . . . . . . .
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 36 9. Options for IATA Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu -[8.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 37 10. Fixing the Number of Digits Computer Command Function /Description Bar Code Command (Z7) START/END Programm.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 38 11. Creating a Prefix and/or Suffix Computer Command Function /Description Bar Code Command (Z7) START/END Prog.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 39 12. Setting Prefixes (Identifying the Symbology) Computer Command Function /Description Bar Code Command (Z7) S.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 40 12. Setting Prefixes (Identifying the Symbology) (continued) Computer Command Function /Description Bar Code Co.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 41 13. Setting Suffixes (Identifying the Symbology) (continued) Computer Command Function /Description Bar Code Co.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 42 14. Direct Input of Numeric Characters Computer Command Function /Description Bar Code Command (Z7) START/END P.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 43 15. Direct Input of Alpha Characters (Z7) START/END Program Menu -[8- 0N N -1O- 0A A -1B- 0O O -1P- 0B B -1C- 0.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 44 16. Direct Input of Control Characters Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu -[8- 1A STX -2B- 1B ETX -2C- 1C CR -2D- 1D LF -2E- 17.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 45 17. Enable Number of Characters/Digits Transmitted (continued) (Z7) START/END Programming Menu -[8- 3G EAN-8 -!.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 46 18. Disable Number of Chara cters/Digits Transmitted Computer Command Function /Description Bar Code Command (Z.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 47 18. Disable Number of Characters/Digits Transmitted (continued) Computer Command Function /Description Bar Code.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 48 19. Communication Parameters (continued) Computer Command Function /Description Bar Code Command (Z7) START/END.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 49 20. Handshaking Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu -[8- I0.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 50 21. Buzzer Operation Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu -[.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 51 21. Buzzer Operation (continued) Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu -[8- W5 Buzzer duration 0.20 sec -X6- % W6 Buzzer duration 0.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 52 22. Positive & Negative Bar Codes Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu -[8- V4 Positive bar code only (black bars/white spaces) -W3- V2 Both positive & negative bar code -W5- % 23.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 53 24. Selecting the Read Mode Computer Command Function /Description Bar Code Command (Z7) START/END Programming .
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 54 24. Selecting the Read Mode (continued) The operation of the scanner in the various read modes is described in the table below. The “Continuous Read” mode is helpful in positioning the scanner for optimum reading.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 55 25. Scanner Timeout (Trigger Enabled Mode only) These commands, which are only applicable in the Trigger Enabled mode, establish the time-out period after the trigger pulse is received.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 56 26. Redundant Decoding The Number of Redundant Decodes determines how many times the scanner must decode a bar code and obtain the same value before it will transmit the data.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 57 27. Transmitting Error Indications (Trigger Enabled only) Computer Command Function /Description Bar Code Comma.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 58 29. Good Read LED Operation Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu -[8- T4 Good read LED disabled after decode -U5- T8 Good read LED ON after decode for .
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 59 30. Sequencer Controls Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu .
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 60 30. Sequencer Controls Computer Command Function /Description Bar Code Command (Z7) START/END Programming Menu .
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 61 Appendix D Dimensional Drawings All dimensions in millimeters.
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 62 Appendix E LPN5627 - Optical Performance (typical unit) Depth of Fiel d, PCS = .
Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount Scanner Page 63 Notes.
デバイスOpticon LPR5627の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Opticon LPR5627をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはOpticon LPR5627の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Opticon LPR5627の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Opticon LPR5627で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Opticon LPR5627を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はOpticon LPR5627の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Opticon LPR5627に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちOpticon LPR5627デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。