OPR 3001 Rugged Handheld Laser Scanner Specifications Manual.
Opticon OPR 3001 S pecifications Manual 2 All information subject to change without notice. Document History Model Number: OPR 3001 Specification Number: SS06106 Edition: 2 Original Spec Number: SS06080 Date: 2006-12-27 Copyright 2007 Opticon. All right s reserved.
Opticon OPR 3001 S pecifications Manual 3 Content s 1. Abstract .................................................................................................................................... 6 2. Overview ........................................
Opticon OPR 3001 S pecifications Manual 4 8.2.1. Settings and Comm unicati on ................................................................................................. 23 8.2.2. Interface Circuit ...............................................
Opticon OPR 3001 S pecifications Manual 5 16.1. Laser Safety ................................................................................................................... 38 16.2. Product Safety ..................................................
Opticon OPR 3001 S pecifications Manual 6 1. Abstract This manual provides specifications for the OPR 3001 handheld laser barcode scann er. 2. Overview The OPR 3001 is a rugged handheld laser barcode scanner with protection against dust and splashing water to ensure reliable operation in h arsh environments.
Opticon OPR 3001 S pecifications Manual 7 3. Physical Features 3.1. Dimensions W 68 X D 150 X H 155 mm (except protruding portion) 3.2. Weight 230 g max (excluding cable). 4. Environmental Specifications 4.1. Operating Temper ature and Humidity Temperature: -10 to +60° C Humidity: 5 to 90% RH 4.
Opticon OPR 3001 S pecifications Manual 8 Conditions Barcode Sample: OPTOELECTRONICS Test Sample PCS: 0.9 Resolution: 0.25 mm Symbology: 9-digit Code-39 Quiet Zone: 10 mm N/W Ratio: 1:2.5 Distance: 100 mm from the edge of scanner Angle: α = 0° β = 15° γ = 0° Curvature: R = ∞ Power supply voltage: 6.
Opticon OPR 3001 S pecifications Manual 9 6. Optical Specifications 6.1. Laser Scanning Specification Parameter Specification Unit Light-emitting Element Red laser diode - Emission Wavelength 650 ±10 (25° C) nm Light Output 1.
Opticon OPR 3001 S pecifications Manual 10 7. Technical Specifications The conditions for technical specifications are as follows, unle ss otherwise specified in each section.
Opticon OPR 3001 S pecifications Manual 11 7.2. Scan Area and Resolution The depth of field is measured from the edge of the scanner. The scanning range is within the circular arc centered on the scan origin. Figure 3: Scan area and resol ution (i n mm) Resolution Symbology PCS Quiet Zone Digit Decode depth (mm) 1.
Opticon OPR 3001 S pecifications Manual 12 7.3. Pitch, Skew, and Tilt 7.3.1. Pitch Angle α = ±35° α = 3 5 ° α = 3 5 ° Figure 4: Pitch.
Opticon OPR 3001 S pecifications Manual 13 7.3.2. Skew Angle and Dead Zone Skew angle: β = ±50° (Excluding dead zone) Dead zone: β = ±8° (There are some areas in which decoding fails due to spec.
Opticon OPR 3001 S pecifications Manual 14 7.3.3. Tilt Angle γ = ±20° γ = 2 0 ° γ = 2 0 ° Figure 6: Tilt angle Conditions Barcode Sample: OPTOELECTRONICS Test Sample Distance: 60 mm from t he edge of the scanner Label: Pitch Angle, Sk ew A ngle, Dead Zone PCS = 0.
Opticon OPR 3001 S pecifications Manual 15 7.4. Curvature With 8-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when R ≥ 15 mm. With 13-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when R ≥ 20 mm. Figure 7: Curvature Conditions Barcode Sample: OPTOELECTRONICS Test Sample PCS = 0.
Opticon OPR 3001 S pecifications Manual 16 8. Interface Specifications 8.1. RS-232C Inte rface Specification 8.1.1. Settings and Communication Reading menu barcodes [ZZ] + [U2] + [ZZ] can set the RS-232C interface default.
Opticon OPR 3001 S pecifications Manual 17 8.1.3. Interface Circuit Figure 8: Interface circuit 8.1.4. Character Format Figure 9:Character format (same for both sendi ng a nd receiving).
Opticon OPR 3001 S pecifications Manual 18 8.1.5. Communication Format Figure 10: Communication format 8.1.6. Handshaking Select handshaking options using the menu or command listed below.
Opticon OPR 3001 S pecifications Manual 19 The scanner stays ON (is able to receive data) except during certain parts of the process, such as receiving data (buzzer command execution), transmitting data, and menu processing. The scanner checks the CTS line before transmitting data.
Opticon OPR 3001 S pecifications Manual 20 c) MODEM The scanner turns CS line ON before transmitting data. Other processes are the same as BUSY/READY. Figure 15: Modem transmit data.
Opticon OPR 3001 S pecifications Manual 21 d) ACK/N AK After data has been transmitted, the scanner expects to receive one of the following responses from the host: • ACK response—Action: The scanner completes transmission with the good-read buzzer and returns to the initial state.
Opticon OPR 3001 S pecifications Manual 22 e) ACK/NAK NO RESPONSE When no response from the host is received within the setting time, the scanner assumes an ACK response, and returns to the initial state without the error buzzer. The other actions are the same as ACK/NAK.
Opticon OPR 3001 S pecifications Manual 23 8.2. USB Interface Specification 8.2.1. Settings and Communication Reading menu barcodes [ZZ] + [SU] + [ZZ] can set the USB interface default.
Opticon OPR 3001 S pecifications Manual 24 9. Cable and Connector 9.1. Cable Specifications 9.1.1. RS-232C Cable (Standard specification) Type: Straight Diameter: Φ 4.
Opticon OPR 3001 S pecifications Manual 25 9.1.2. USB Cable (Standard specification) Type: Straight Diameter: Φ 4.8 ±0.5 mm Length: 1500 ±50, -0 mm Cores: 4 insulated wires, 1 conductive wire Weigh.
Opticon OPR 3001 S pecifications Manual 26 9.1.3. Wedge Cable (Standard specification) Type: Y cable Diameter: Φ 4.8 ±0.5 mm Length: 1500 ±50 , -0 mm Cores: 8 insulated wires, 1 conductive wire Wei.
Opticon OPR 3001 S pecifications Manual 27 9.2. Scanner Connector Specification CN801 (13-pin) Signal Name Pin Number RS-232C USB Wedge 1 NC VCC VCC 2 R×D NC NC 3 T×D NC NC 4 NC NC CPU_CLK 5 NC NC CPU_DATA 6 GND GND GND 7 NC USB+ NC 8 NC USB- NC 9 NC NC KB_DATA 10 NC NC KB_CLK 11 CTS NC NC 12 RTS NC NC 13 VCC NC NC 10.
Opticon OPR 3001 S pecifications Manual 28 * If you are using software version TS01Y04 or later, it is not necessary to configure the foregoing settings.
Opticon OPR 3001 S pecifications Manual 29 10.2. Default Settings 1: Readable Codes Code type Reading Transmit Code Length Transmit CD Calculate CD Prefix Suffix Transmit Other UPC-A X - C.
Opticon OPR 3001 S pecifications Manual 30 Notes: • In the “Reading” column, “ ” means “Enable reading” and “ X ” means “Disable reading.” • In the “Transmit code length” column, “ ” means “Transmit code length” and “ X ” means “Do not transmit code length.
Opticon OPR 3001 S pecifications Manual 31 11. Serial Number The serial number as shown below is affixed to the scanner. Figure 22: Serial number diag ram.
Opticon OPR 3001 S pecifications Manual 32 12. Packaging Specifications 12.1. Individual Packaging Specification Put the scanner in a protective foam bag and place it in a sin gle packing box. The scanner shown is an RS-232C unit. Descriptions on an individual packaging box label differ, depending on the interface type.
Opticon OPR 3001 S pecifications Manual 33 12.2. Collective Packaging Specification The scanner shown is an RS-232C unit. Descriptions on a collective packaging box label differ, depending on the interface type. The “RO” mark may be indicated on the upper side of the individual packaging box label.
Opticon OPR 3001 S pecifications Manual 34 13. Durability 13.1. Electrical Noise No malfunction should occur when sinusoidal electrical noise (10Hz -100kHz, < 0.1Vpp) is added to a power supply line. Conditions Barcode Sample: OPTOELECTRONICS Test Sample PCS: 0.
Opticon OPR 3001 S pecifications Manual 35 13.3. Shock 13.3.1. Product Drop Test No malfunction should occur after the following drop test. As shown below, drop the scanner from 200 centimeters above the concrete floor (three times from each of 6 angles).
Opticon OPR 3001 S pecifications Manual 36 13.6. Cable Strength 13.6.1. Cable Pull Strength Affixed the scanner to an immovable object and pulled it using a force of 49N (5.0 kgf) for 1 minute. Observed no abnormality in either structure or performance.
Opticon OPR 3001 S pecifications Manual 37 15. Auto Trigger (Option) The OPR 3001 has an optional auto trigger setting, which starts barcode reading auto matically by using sensor detection. When auto trigger is enabled, a laser beam is emitted and points to the auto trigger area.
Opticon OPR 3001 S pecifications Manual 38 15.1.1. Auto Trigger Settings Functions Menu labels Menu codes SET _ZZ_ ZZ Disable auto trigger _+F_ +F Enable auto trigger _+I_ +I END _ZZ_ ZZ 16. Regulatory Compliance 16.1. Laser Safety The scanner emits laser beams.
Opticon OPR 3001 S pecifications Manual 39 17. Safety 17.1. Shock • Do not throw or drop the scanner. • Do not place heavy objects on the cables. 17.2. Temperature Conditions • Do not use the scanner at temperatures outside the specified range. • Do not pour boiling water on the scanner.
Opticon OPR 3001 S pecifications Manual 40 18. Mechanical Drawing Dimensions: 3 W 68 X D 150 X H 155 (mm) (except protruding portion) Figure 28: Mechanical draw in g.
デバイスOpticon OPR 3001の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Opticon OPR 3001をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはOpticon OPR 3001の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Opticon OPR 3001の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Opticon OPR 3001で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Opticon OPR 3001を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はOpticon OPR 3001の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Opticon OPR 3001に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちOpticon OPR 3001デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。