Orionメーカー7817の使用説明書/サービス説明書
ページ先へ移動 of 20
INSTRUCTION MANUAL IN 296 Rev . B 02/09 Providing Exceptional Consumer Optical Products Since 1975 Customer Support (800)-676-1343 E-mail: support@telescope.
2 Figure 1. The SkyView Pro GoT o System (not all par ts on par ts list are shown) Motor control box brack et R.A. GoT o motor cover Dec. GoT o motor cover Dec. GoT o motor Motor control box GoT o hand controller brack et GoT o hand controller Motor cables GoT o hand controller cable R.
3 1. Par ts List Qty . Description 1 Declination (Dec.) GoT o motor assemb ly 1 Right ascension (R.A.) GoT o motor assemb ly 2 Brass gears w/ 2mm soc ket-head set screws 1 Motor control bo x 1 Motor c.
4 2. Remove the R.A. slow-motion control knob from the R.A. worm gear shaft. The slow-motion knob will not be usable once the SkyVie w Pro GoT o system has been installed. All slo w-motion adjustments will be made using the GoT o hand controller . 3. The R.
5 Attaching the Dec. GoT o Motor Bef ore attaching the Dec. GoT o motor dr iv e, the telescope tube must be remov ed from the equatorial mount. 1. Remov e the Dec. slow-motion control knob from the Dec. worm gear shaft. The Slow-motion knob will not be usable once the SkyVie w Pro GoT o system has been installed.
6 4. Make cer tain that the teeth of the smaller gear of the Dec. GoT o motor assembly meshes with the brass gear . Also, make cer tain the gears are not too tightly pressed togeth- er . Y ou can adjust the wa y the gears mesh b y tightening or loosening the soc ket-head cap screw that is used to attach the Dec.
7 3. The GoT o Hand Contr oller Once aligned, the GoT o hand controller and dual-axis GoT o motors allow you to automatically point y our SkyView Pro mounted telescope at a specific object, or tour the skies with pushbutton simplicity . The user-friendly menu allo ws auto - matic slewing to o ver 13,400 objects .
8 are used f or data entr y and as quick ref erence keys . T OUR button: T akes y ou on a preset tour of the best night sky objects visible RA TE button: Changes the speed of the motors when the directional b uttons are pressed. There are 10 speeds to choose from, with 0 being the slow est and 9 being the fast - est.
9 9. Enter y our current local time using the 24 hour cloc k f or mat (e xample: 2:00PM = 14:00). Press ENTER to view the time you entered. If the time is incorrect, press ESC to go back to the pre vious screen. If the time is correct, press ENTER again.
10 1. F rom the alignment screen, select “1-Star Align” using the scroll buttons . Press ENTER to confir m your choice . 2. The hand controller will provide a list of stars av ailable in your current sky for you to choose as the first alignment star .
11 matically be chosen b y the hand controller for y our vie wing pleasure. Use the scroll buttons to view the diff erent deep- sky objects that are a vailab le for viewing through the tour function. Choose the desired object by pressing ENTER. The LCD screen will displa y the coordinates of the chosen object.
12 Setup Menu. Set T racking: -Sidereal Rate: Activates trac king at sidereal rate. This is the def ault tracking rate . -Lunar Rate: Activates trac king at lunar rate. -Solar Rate: Activates trac king at solar rate. -PEC + Sidereal: Activ ates sidereal rate tr acking with P eriodic Error Correction.
13 Auto Guiding F or astronomical imaging, the SkyView Pro GoT o motor con- trol box has a designated autoguider jack. The pin-outs on the 6 pin modular jac k are SBIG compatible and can be used with most autoguiders av ailable. Ref er to Figure 16 when connecting the autoguider cable to the mount and calibrating the autoguider .
14 SkyV iew Pr o GoT o Hand Contr oller Menu T r ee.
15 3. T echnical Specifications Motor drives: Dual-axis, GoT o comput- erized. Operation: Nor thern or Souther n hemisphere A utoguiding rates: 1.25X / 1.5X / 1.75X / 2X sidereal rate P ower requirrement: 1 2V D C, 2 A ( t ip p o si - tive) Motor type and resolution: Microstep dr iv en stepper motors Slew speeds: Rate 0 = 1.
16 Incorrect star alignment, loose R.A. or Dec. lock-knobs , or “cone” error . If the GoT o hand contoller puts the star outside the eyepiece field of view , you need to determine which of these f actors is causing the pointing inaccur acy . T o deter mine if the inaccuracy is caused by “cone” error , simply mov e the telescope about the R.
17 Note: This calibration method can be applied to both refract - ing and reflecting telescope designs. Diff erences in the optical path of telescopes do not affect how the telescope tube and tube rings should be adjusted on the mounting plate. Figure 20.
18 Appendix B: Periodic Err or Corr ection (PEC) (Requires an illuminated reticle ey epiece capable of producing at least 300X magnification when used with your telescope.
19 The SkyView Pro GoT o system will emit a “beep” sound and displa y “Record completed” when the training time is up . Press any b utton to exit from the PEC T raining upon completion. Play Bac k the PEC Record PEC tracking can be activ ated under the Setup menu or by pressing the Setup quick ref erence b utton when needed.
20 Orion T elescopes & Binoculars 89 Hangar W ay , Watsonville, CA 95076 Customer Support Help Line (800)‑676‑1343 • Day or Evening One-Y ear Limited W arranty This Orion SkyVie w Pro GoT o system is w arranted against defects in materials or wor kmanship f or a period of one year from the date of purchase.
デバイスOrion 7817の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Orion 7817をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはOrion 7817の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Orion 7817の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Orion 7817で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Orion 7817を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はOrion 7817の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Orion 7817に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちOrion 7817デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。