1 W arranty Summar y Dear OutBack Customer , Thank you for y our purchase of OutBack products. W e make ever y e or t to assure our power con version products will give you long and r eliable ser vice for your renewable energy syst em.
2 T ABLE OF C ONTENTS W arranty Summar y......................................................................................................................................................................... 1 W elcome to the OutBack P ower Systems FX Series I nverter/Charger System .
3 Auxiliary (AUX) F unctions...................................................................................................... .................... . .............................47 List of A UX F unc tions.........................................
4 W elcome to the OutBack P ower Sy stems FX Series Inverter/Charger Syst em The FX Series Inver ter/Charger o ers a complete power con version system—DC to A C, battery charging , and an AC T ransfer Relay—and can be used for stand-alone or back -up applications.
5 FX MODES AND PROPER TIES Each OutBack FX Inver ter/Charger comes with various default values set at the factory. T ypically, a single FX installation will retain these values, but multiple FXs will r equire programming using the OutBack MA TE. Viewing the status of an FX and adjusting its functions also requires a M A TE.
6 Use the search sensitivity screen to determine the size of an AC load needed f or the FX to turn ON and leave SEARCH mode. • Pr essing decreases sensitivity (a bigger load is needed to turn the FX.
7 Pr essing returns you to the SE TUP/FX/ SEARCH screen. Pr essing returns the user to the choose category screen. Pr essing returns to the MAIN Menu. F rom the M AIN screen, pr ess .
8 T o choose your A C input source in the ac tr ansfer control scr een, press or . P ress to view the next screen. By using and , the a c1/grid menu sets the maximum current the FX will allow to be drawn from the g rid by either AC loads or the batteries (during recharging).
9 ADV ANCED SCREENS All the FX operation settings can be adjusted in the MA TE’ s ADV ANCED screens, including some pr evi- ously discussed in the INPUT and SETUP menus. Changing the settings under any menu will a ect the values in all menus. The ADV ANCED screens are accessed via the passw ord 141 .
10 ADV choos e device : FX CC D C MA TE ADV/FX/P AGE 1----------------- choos e categor y : ADV INV CH GR PG2 ADV/FX/INVER TER -------P00 search 6 se nsitiv ity DOWN INC DEC PO R T ADV/FX/INVER TER --.
11 ADV/FX/INVER TER -------P00 search 60 cycles pulse spacing DOWN INC DEC PO R T ADV/FX/INVER TER -------P00 low ba tter y 10.5 vdc cut-ou t set point DOWN INC DEC PO R T ADV/FX/INVER TER -------P00 low ba tter y 12.
12 ADV/FX/INVER TER ------------- reset FX to facto r y defaul ts DOWN MORE ADV/FX/INVER TER ------------- in verter pr ogramming com pleted TOP AD V MAIN Pr essing returns to the beginning of the ADV/FX/INVER TER menu. returns to the ADV ANCED screens and displays the MAIN scr een.
13 ADV choos e device : FX CC D C MA TE ADV/FX/P AGE 1----------------- choos e categor y : ADV INV CH GR PG2 ADV/FX/CH ARGER ---------P00 char ger 18.
14 ADV/FX/CH ARGER ---------P00 absorb 01.0 hrs time limit DOWN INC DEC PO R T ADV/FX/CH ARGER ---------P00 oat 13.6 v dc set poi n t DOWN INC DEC PO R T ADV/FX/CH ARGER ---------P00 oat 01.0 hr s time period DOWN INC DEC PO R T ADV/FX/CH ARGER ---------P00 re oat 12.
15 ADV/FX/CH ARGER ---------P00 equalize 14.6 vdc set po int DOWN INC DEC PO R T ADV/FX/CH ARGER ---------P00 equalize 01.0 hrs time period DOWN INC DEC PO R T ADV/FX/CH ARGER ------------ charger pro gram ming com p eted TOP AD V MAIN An occasional equalize charge helps destratify the batteries for a longer working life.
16 GENERA T OR MENU OutBack o - grid and mobile FX Inverter/Chargers are prog rammed to use an AC generator as their default source of AC input. The CHARGER GEN screens allow a user t o adjust the input voltage window and time delays of thei AC input.
17 ADV/FX/GEN---------------P00 ac2/gen 108 vac low er limit DOWN INC DEC PO R T ADV/FX/GEN---------------P00 ac2/gen 140 vac upper limi t DOWN INC DEC PO R T ADV/FX/GEN---------------P00 ac2/gen 7.
18 ADV/FX/GEN---------------P00 ac2/gen OFF support DOWN OFF ON PO R T ADV/FX/GEN-------------------- GEN pr ogramming com pleted TOP AD V MAIN This feature is not operational at this time. P ress to view the nal GEN screen. Pr essing returns to the beginning of the ADV/FX/INVER TER menu.
19 FX Series Inverter/Charger Pr ogramming NO TE: Please see the FX and VFX Series Inver ter/Charger Installation Manual t o install, wire , and connect each FX Series I nverter/Charger . This programming manual assumes all FXs have been installed and are ready t o program accor ding to the way they were wired .
20 AC Breakers O DC Breakers O Components and C onnections 1. With all AC and DC breakers OFF , connect all FXs to the HUB with individual lengths of CA T5 cable . a) Connec t the OutBack MA TE after all other components, including any OutBack Charge C ontrollers, ha ve been connected and powered up .
21 LED Color LED A ction LED I ndicates Green Solid GREEN I nv erter ON Flashing GREEN Search M o de/Sla ve P ower Off In verter OFF Y ellow Solid YELLOW A C Source is Connecteced Flashing YELLO W A C.
22 3. After powering up the components, connect the MA TE t o the HUB. a) Plug the MA TE into the 1st MA TE Port on the HUB. b) The M A TE will pow er up and should recogniz e any component connected to the HUB . c) The MA TE can then pr ogram the FXs.
23 3 kW 120 V AC 3 kW 120 V AC 9 kW 120 V AC LOA D 3 kW 120 V AC ST ACKING OPTIONS OutBack FXs can be stacked in one of ve di erent con gurations: 1.
24 3. OutBack Series • 2-10 FXs are wired to two 120V A C output legs producing 240 V AC between them. • This system requires an FW -X240 or PSX -240 Auto T ransformer . • 240V AC can be produced on one leg if the load is ten amps or less; an FX on one leg can po wer loads on the other leg, helping to balance loads .
25 5. 3-Phase • Three —and only three— FXs are connected, one to each of thr ee 120 V AC output legs that produce 208 V AC between any two legs of the system. • The HUB requires a jumper between the two Slave FXs f or this stacking to func tion (see HUB Manual).
26 2. Classic Slave • Classic Slave is the desig nation of the second FX in a two-inver ter , split-phase system that pr oduces 240 V AC without using an FW- X240 Auto T ransformer .
27 Once the MA TE recognizes each FX (and Char ge Controller or C C ), push and hold the rst t wo soft keys simultaneously to return to the M AIN menu. T o pr ogram the FXs, go t o the ADV/FX/ST ACK menu on the MA TE navigating with the following steps: Pr ess .
28 ADV choos e device: FX CC D C MA TE ADV/FX/P AGE 1----------------- choos e categor y : ADV INV CH GR PG2 On the ADV/FX/P AGE 1 screen, pr ess and go to the ADV/FX/P AGE2 screen. In the AD V menu, pr ess . ADV/FX/PG2--------------------- choos e categor y : PG1 GRID GEN PG3 Pr ess which leads to the AD V/FX/P AGE3 screen.
29 ADV/FX/S T ACK-----------P01 stack 1-2ph Mast er phase DOWN INC DEC PO R T Stacking the FX Ser ies Inverter/Chargers begins on this screen. See speci c stacking procedures in the next sec tion. ADV/FX/S T ACK------------P01 stack 1-2ph Mast er phase DOWN INC DEC PO R T P or t 01 always takes the Master FX.
30 1-2ph Master With the P or t 01 FX as the Master , press the <PORT> soft key to change the remaining P or ts and designate the r emaining FXs as Slaves.
31 ADV/FX/S T ACK------------P02 stack OB Sla ve L1 phase DOWN INC DEC PO R T OutBack (OB) SLA VE L2 • Set the FX’ s you want as series Slaves (L eg 2) to OB Slave L2. • This FX is considered the L2 phase. T o use OutBack Slav e L2 stacking, press in the ADV/FX/ST A CK OB screen to change the stack phase from OB Slav e L1 to OB Slave L2.
32 ADV/FX/S T ACK----------P01 stack 3ph Mast er phase DOWN INC DEC PO R T 3-Phase (3-ph) Slave • Set the two Slave FX’ s to 3ph Sla ve and make sure they are in P or ts 02 and 03 of the HUB. • There are no selections to di erentiate between phases B and C.
33 Introduction to P ower Sav e Lev els Depending on the model, each FX consumes 20-25 watts of power when it r emains on, even if it isn ’t actively inverting or charging. OutBack P ower Systems o ers the option to shut down (put into Silent mode) some or all of the Slave FXs until the loads r equire them to come on again.
34 The default value for the pow er save level slave adjust only screen is 1. P ress or to adjust this value. P ress to change the value of each Slave FX.
35 NO TE: I f you are doing OutBack Stacking, turn on the FW- X240 Auto T ransformer breaker now . O ther wise, go to the next step. • Verify the AC voltage output thr ough the MA TE following path: P A TH MAIN--------------------- ST A TUS------------ ST A TUS/FX/P AGE1------- Float P00 ST A TUS/FX/METER —P00 12.
36 If the FX’ s AC source is available , the yellow AC IN ST A TUS light will blink . The FX will connect to the utility grid when the voltage is within 108-140V AC and the frequency between 54-66 H z. After about 30 seconds, the AC IN light should st op blinking and stay lit.
37 Stacking System Examples Dual-Stacked System U sing Classic Stacking • The system includes only two FXs and must be set up as described here. • The bottom FX Series I nverter/Charger is plugged into P or t 01 of the HUB and the next or second FX is plugged into P or t 02.
38 OutBack P arallel Stack ing • F our FXs in a single system are ref erred to as a Quad Stack. • The FX installed at the bottom of the stack is plugged into P or t 1 of the HUB. • The second, third, and f our th FXs are plugged into P orts 2, 3, and 4 respectively .
39 Rank ing the Slaves • Star t from the last ADV/FX/ST ACK screen. ADV/FX/S T A CK---------P02 power sa ve level 1 slave ad just o nly DOWN INC DEC PO R T ADV/FX/S T A CK-----------P04 power sa ve .
40 After setting up your OutBack P arallel Stack ing and establishing the Master and Slave order , shut o all the AC input and output breakers and check your system via the f ollowing MA TE scr een.
41 OutBack Series / P arallel Stacking OutBack Series/P arallel Stack ing is a versatile con guration for a system using between two and ten FXs with AC outputs connected to one of the two 120 V AC legs. Although it’ s acceptable to divide the FXs unevenly between the two 120 V AC legs, at least one FX must be on each leg.
42 PRESS <INC> UNTIL 141, THEN PRESS ENTER ADV/P ASSW ORD--------------- enter the passw ord 132 ENTER INC DEC EXIT ADV/S ET TINGS/W ARNING chang es made could adversely a ect system performa.
43 ADV/FX/S T A CK---------P03 stack OB Slav e L2 phase DOWN INC DEC PO R T ADV/FX/S T A CK----------P04 stack OB Slav e L2 phase DOWN INC DEC PO R T ADV/FX/S T A CK----------P04 stack OB Slav e L2 phase DOWN INC DEC PO R T Pr ess the <PORT> soft key again until P or t 04 appears on the screen.
44 Rank ing the Slaves: • F rom the last scr een— ADV/FX/ST ACK P04—pr ess the <DOWN> soft k ey twice to get into the power save level slave adjust only menu. This menu allows you to set the or der in which the Slave FXs come “ON” • Pr ess the <PORT> soft key until P03 is displayed.
45 With OutBack Series/P arallel Stack ing and the Master and Slave or der established, check the system: • F rom the ADV/FX/ST ACK po wer save level slave adjust only scr een, press the <DOWN> soft key , the <TOP> soft ke y , and then the <DOWN> soft k ey .
46 3-Phase Stacking ( Thr ee FX S eries Inverter/Chargers Only) A 3-phase stacked system with only three FXs must be set up as described here: • T urn o all AC output and AC input breakers befor e powering up FX’ s. • Plug the top FX into P or t 01 of the HUB, the 2nd FX into P or t 02, and the 3rd FX into P or t 03.
47 ADV/FX/S T A CK-----------P02 Stack 3ph Master phase DOWN INC DEC PO R T ADV/FX/S T A CK-----------P02 stack 1-2ph Master phase DOWN INC DEC PO R T ADV/FX/S T A CK------------P03 stack 3ph Slav e p.
48 The screen displays 132. P ress the button until it scrolls to the passw ord 141. ADV/P ASSW ORD---------------- ente r the passwor d 132 ENTER INC DEC EXIT ADV/P ASSW ORD ente r the passwor d 141 .
49 ADV/FX/PG2------------------- choos e categor y : PG1 GRID GEN PG3 Pr ess which leads to the AD V/FX/P AGE3 screen. ADV/FX/P AGE3------------------ choos e categor y : PG2 A UX ST A CK PG4 On the ADV/FX/P AGE3 screen, pr ess to adjust the A UX output set points and operation.
50 LIST OF A UX FUNC TIONS • Cool F an activates the standard T ur boF an which cools the FX during an over temperatur e condition. • Divert DC and Divert AC allows the A UX to diver t excess r enewable energy to a DC or A C load, respectively . This allows control of ener gy sources such as wind turbines or hydr o- generators.
51 ADV/FX/A UX---------------P00 aux o utp ut Remo te functio n DOWN INC DEC PO R T F rom the r emote aux output function screen, press . This will bring up the rst of several screen used to adjust which ev er mode you have chosen f or the AUX function.
52 ADV/FX/A UX----------------P00 ven tfan 13.0 vdc on s etp oint DOWN INC DEC PO R T When the A UX is set to ventfa n , a fan ventilates a batter y enclosure . The ventfan on setpoint establishes the batter y voltage which ener gizes the A UX and thus the fan for a one minute period.
53 BA T TERY CHARGING INSTRUC TIONS Keeping your batter y bank energiz ed is very impor tant. Although a batter y bank can last for many years if properly cared f or , it can also be ruined in a shor t period of time if neglected.
54 12 VDC System DEF AUL T MINIMUM MA XIMUM Float Voltage 13.6V 12V 15V Absorb Voltage 14.4V 13V 16V EQ V oltage 14.4V (24VDC Grit- Tie=29.2) 14V 17V ReFloat 12.
55 T WO Y EAR LIMITED W ARRANTY INFORMA TION FX Series Inver ter/Charger P roducts OutBack P ower Systems , Inc. (“OutBack ”) provides a two year (2) limited warranty (“ Warranty ”) against defects in materials and workmanship for its FX/VFX Series I nverter/Charger products (“P roduct(s)”) if installed in xed location applications.
56 T o request warranty ser vice, you must contact OutBack T echnical Ser vices at (360) 435-6030 or support@ outbackpower .com within the e ective warrant y period. OutBack T echnical Suppor t will attempt to tr oubleshoot the product and validate that the failure is pr oduct related.
57 Limited W arranty Registra tion Complete this f orm to request a Limited Warranty , and return it to: Outback P ower Systems Inc. 19009 62nd Ave . NE Arlington, W A 98223 NO TE: Please submit a cop.
European Sales O c e Barcelona, ESP AÑA (+34) 600.843.845 19009 62nd Avenue NE Arlington, W A 98223 USA (+1) 360.435.6030 www.outbackpower .com 900-0086-01-00 REV B.
デバイスOutback Power Systems FX SERIESの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Outback Power Systems FX SERIESをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはOutback Power Systems FX SERIESの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Outback Power Systems FX SERIESの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Outback Power Systems FX SERIESで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Outback Power Systems FX SERIESを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はOutback Power Systems FX SERIESの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Outback Power Systems FX SERIESに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちOutback Power Systems FX SERIESデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。