PanasonicメーカーFP0 Seriesの使用説明書/サービス説明書
ページ先へ移動 of 27
FP0 Series Programmable Controller P anasonic ... the new name f or CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.
2 FP0 – Super Compact PLC Incredibly small, alone or even as multiple combined units A control unit a mere 25mm in width. Even expanded to I/O 128 points, the width is still only 105mm. The attachment area is the smallest in its class. The control unit's dimensions are: W25* x H90 x D60mm.
Either 10 Points or the Maximum of 128 Points Y ou save this much space! 3 The expansion unit can be attached easily without any cables. The expansion unit can easily be attached directly to the control unit.
4 FP0 CPU Units A rich line-up of both single and combined units = + =+ =+ =+ =+ + + =+ + =+ + = +++ = +++ 22 Input 12 Output 10 14 Input 8 Output 6 8 Input 4 Output 4 26 Input 14 Output 12 10 Input 6.
FP0 Expansion Units Choose the number of I/O points to suit the application 5 Combinations with transistor output type – Examples = + =+ =+ =+ =+ + + =+ + =+ + = +++ + = +++ 48 Input 24 Output 24 32.
6 FP0 – Impressive Capabilities High specifications for both speed and capacity 0.9µs per basic instruction. Pulse catch and interrupt input functions meet the need for high-speed response. High-speed execution Execution speed of 0.9µs per basic instruction.
FP0 – Impressive Capabilities FP0 functions 7 Equipped with 2-axis independent positioning and high-speed counter for support of PWM output. Pulse output function (For transistor output type only) The unit comes equipped with 2 channels for the output of up to 10kHz pulses (5kHz during 2-channel output).
8 FP0 Communication Serial interfaces and modem compatible Programming interface TOOL-Port (also for communication) In Computer Link mode, this port offers access to the entire FP0 memory area.
FP0 Communication Easier maintenance than ever before 9 Maintenance saving ■ Overwrite function in RUN mode It is possible to overwrite a program while the FP0 is running, such as during program debugging and startup adjustments. ■ Backup battery unnecessary The program memory uses EEPROM.
10 FP0 PROFIBUS DP Slave or Remote I/O Unit For cost effective control of distributed field device The FP0 DPS2 can operate either as a DP slave module or as a remote I/O system to which different decentralised inputs and outputs can be connected. A DIP switch can be used to switch between the two modes: Mode 1: DP-Slave module.
11 FP0 S-LINK Unit Connects directly to the S-LINK for reduced wiring Wire-saving The use of wires is greatly reduced and the number of connecting terminal blocks is minimized, resulting in large reduction in cost, as well as, the waste generated during wiring.
12 FP0 MEWNET -F Unit Networking units The FP0 can be used as a slave station for MEWNET -F (remote I/O system) by adding I/O link unit. MEWNET -F is a reduced-wiring remote I/O system that connects PLCs located separately and I/O slave stations with 2-core cabling.
The FP0-TC4 and FP0-TC8 thermocouple units are suitable for user friendly temperature acquisition using standard thermocouples with high precision. ■ Up to three units can be added to each control unit, enabling temperature control of up to 24 channels.
14 Analogue Signal Processing FP0 Analogue Units FP0-A21 2 Inputs/1 Output FP0-A80 8 Inputs ■ Multimode A/D, D/A conversion ■ High resolution: 12-bit V oltage, current and temperature selectable .
Analogue Signal Processing FP0 Analogue Units 15 Item Description Rated operating voltage Operating voltage range 24VDC 21.6 to 26.4VDC Rated current consumption FP0-A80: 60mA or less, FP0-A21/A04V : .
16 FP0 RTD Input Expansion Unit User friendly acquisition of temperatures with high precision Features FP0-R TD6 6 channels ■ The module can be easily installed in an existing system: Special connec.
Item Description Rated operating v oltage 24 VDC Operating v oltage range 21.6 to 26.4 VDC Allow able no voltage time 10 points, 14 points type 5ms (at 21.
18 FP0 Series Specification tables Item Description Programming TOOL-Port Communication COM-Port RS232, mini DIN socket (5 pin), 9600 or 19200 BAUD, (8 data bits, odd parity , 1 stop bit), Computer link for programming and communication with MEWTOCOL.
19 Control FPWIN Pro PLC programming software conforming to IEC 61131-3 FP Programmer II V er. 2 Programming cable AFC8513D Programming cable AFC8523 Programming software Connect with RS232C cable FP0.
20 Control FPWIN GR PLC programming software for easy operation Program status display Function instruction list Classified by type, function commands can be selected from the displayed list. (Simple help included.) Menu Program display T ool bar Access often-used functions using icons.
Control CommX, PCW A Y , OPC Server V isualisation software for ready made or customised solutions 21 The connection in ActiveX technology . ■ Connects your Visual Basic application to Matsushita PLCs. ■ Gives you the possibility to easily develop highly customised control solutions.
Notes: ■ A power cable (order number AFP0581) is enclosed with the control unit and the relay output type upgrade units (T ransistor output type upgrade units do not require a power cable). ■ T wo Phoenix terminals (9-pin) are needed with the relay output type terminal type.
FP0 Analogue and Networking Units Products and order numbers 23 3 points Input 2 points T erminal type Order number: FP0-A21A T erminal type Order number: FP0-A80A Output 1 points 8 points Input 8 poi.
Terminal screwdriver Necessary when wiring relay output type & terminals (Phoenix). Attachment example Wiring tools Parts for attachment I/O cables & networks Order number : AFP0806 Slim attachment plate model Screw-stop attachment plate. Slim model.
Programming T ools and Current Consumption List Products and order numbers 25 Control Control Made in Germany Made in Germany Matsushita Electric Works, Ltd.
26 FP0 Series Power Supplies ■ Incredibly small size: - FP0 power supply: 90 x 60 x 30.4mm - FP power supply: 115 x 75 x 42mm ■ Maximum output current: - FP0 power supply: 0.7A (24VDC) - FP power supply: 2.1A (24VDC) ■ Multiple voltage input: 85 to 265V AC ■ Optimal protection: overvoltage, overcurrent, overheating, etc.
FP0 Product Overview Order numbers 27 1. Control Units Product Name Part Number FP0-C10RS, 6 Inputs / 4 Outputs (p+n / Relay) FP0-C10RSA FP0-C10CRS, 6 Inputs / 4 Outputs (p+n / Relay), RS232 COM-P.
デバイスPanasonic FP0 Seriesの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Panasonic FP0 Seriesをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPanasonic FP0 Seriesの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Panasonic FP0 Seriesの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Panasonic FP0 Seriesで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Panasonic FP0 Seriesを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPanasonic FP0 Seriesの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Panasonic FP0 Seriesに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPanasonic FP0 Seriesデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。