DPoE ™ Power System User’s Guide Issue 1.0 Part Number: PN380 February 2005 2005 PANDUIT Corp. All Rights reserved www.panduit.com.
PANDUIT DPoE Power System User’s Guide Issue 1.0 Part Number: PN380 Safety Warnings The DPoE Power Patch Panel Power System is for u se in restricted access locations only.
PANDUIT DPoE Power System User’s Guide Issue 1.0 Part Number: PN380 The foregoing warranty shall not apply to defect s resulting from improper or inadequ ate maintenance by Buyer.
PANDUIT DPoE Power System User’s Guide Issue 1.0 Part Number: PN380 TABLE OF CONTENTS Safety Warnings ............................................................................................................................. i FCC Compliance Statement .
PANDUIT DPoE Power System User’s Guide Issue 1.0 Part Number: PN380 Table 3: Heat Dissipation ...................................................................................................... ........ 3 Table 4: Recommended AC Circuit Break er and Wire Sizes…………………………………….
PANDUIT DPoE Power System User’s Guide Issue 1.0 Part Number: PN380 OVERVIEW The DPoE TM Power Patch Panel ( PANDUIT part number DPoE24U1X) provide s a reliable and cost- effective solution for Power over Ethernet (PoE) applications, complaint with the IEEE 802.
PANDUIT DPoE Power System User’s Guide Issue 1.0 Part Number: PN380 Table 1: DPoE Power Components Available from PANDUIT Corporation PANDUIT Part Number Description Individual power supply DPoEPWRB.
PANDUIT DPoE Power System User’s Guide Issue 1.0 Part Number: PN380 Package Contents The DPoE Power system chasses ( PANDUIT p art number DPoEPWRCM or DPoEPWRCU) are shipp ed with the following included items. Table 2: Package Contents Item Quantity Notes DPoE Power System User’s Guide 1 This document.
PANDUIT DPoE Power System User’s Guide Issue 1.0 Part Number: PN380 R e ctifie rs 12 3 Feed 1 Feed 2 A C In N+1 DC Out Feed 3 Figure 1: Individual AC F eed Wiring Architecture Each individual AC feed should be protected u sing a circuit breaker as listed in Table 4: Recom mended AC Circuit Breaker and Wire Sizes .
PANDUIT DPoE Power System User’s Guide Issue 1.0 Part Number: PN380 CAUTION: ALWAYS FOLLOW NEC GUIDELINES AND YOUR LOCAL COMPANY PRACTICES WHEN SELECTING DC WIRING AND PROTECTION. Table 5: Minimum Recomm ended DC AWG for 90° C Cabling for Unprote cted Outputs shows recommended wire sizes base d on ampacity.
PANDUIT DPoE Power System User’s Guide Issue 1.0 Part Number: PN380 B u t t s pli ces conn ector s P ower conn ecto r ho us i n g w i th w i r e l eads 48 VDC Su ppl y Po w er Co nne ct o r o n r e .
PANDUIT DPoE Power System User’s Guide Issue 1.0 Part Number: PN380 Table 5: Minimum Recommended DC AWG for 90° C Cabling for Unprotected Outputs Total Rectif ier Current Rating (A) Wire and Lug Gauge (AWG) using 90 ° C wi re (NEC Table 310.
PANDUIT DPoE Power System User’s Guide Issue 1.0 Part Number: PN380 Table 7: PANDUIT Corporation Contact Information PANDUIT Technical Support Fax: 1-708-444-6993 E-mail: cs@panduit.com For Installation Instructions in Local Languages and Technical Support www.
PANDUIT DPoE Power System User’s Guide Issue 1.0 Part Number: PN380 I EC320 AC cord Cord Bracket Sec uri ng Screw Figure 5: Cord Bracket Figure 6: Chassis (Rear View) - AC Connections #4-4 0 S cr ew.
PANDUIT DPoE Power System User’s Guide Issue 1.0 Part Number: PN380 DC Output DC connections are acco mplished via the rear termin al blocks and bulk output conne ction as shown in Figure 9: Chassis (Rear View) - DC Connections .
PANDUIT DPoE Power System User’s Guide Issue 1.0 Part Number: PN380 Ethernet Connections The Ethernet port on the back of the DPoE Power Sy stem chassi s is used to provide the conn ection between the NIC card and the manage ment system.
PANDUIT DPoE Power System User’s Guide Issue 1.0 Part Number: PN380 Short Circuit and Current Limit I Limit can be adjusted up to +105% of the rated current of the rectifie r (See Table 4: Recommended AC Circuit Breaker and Wire Sizes ).
PANDUIT DPoE Power System User’s Guide Issue 1.0 Part Number: PN380 This following information is only applica ble to chasses with NIC cards. The NIC card can be connected via a standa rd straight through RJ45 patch cord (such as PANDUIT part number UTPCH3 or UTPSP3), through a hub or router, or via a crossover cord fo r direct connection.
PANDUIT DPoE Power System User’s Guide Issue 1.0 Part Number: PN380 Parameter Description Default Setting BDT TIME MNT Sets the length of time (minutes) that the battery test will run. 30 min. BDT ALRM Voltage Sets the voltage at which an alarm will be generated if the battery voltage falls below this level during the battery test.
PANDUIT DPoE Power System User’s Guide Issue 1.0 Part Number: PN380 15 Parameter Description Default Setting High temperature alarm release (NIC Card only) The temperature value at which the controller will release a HIGH TEMP alarm. (For systems usin g the NIC card only.
デバイスPanduit PN380の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Panduit PN380をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPanduit PN380の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Panduit PN380の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Panduit PN380で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Panduit PN380を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPanduit PN380の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Panduit PN380に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPanduit PN380デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。