IPD4000E 4-Module IP DSLAM: Internet Protocol Digital Subscriber Line Access Multiplexer Installation Instructions © Copyright 2004 Net to Net Technologies, Inc.
Contents 1.0 INSTALLATION 1.1 Unpack and Inspect the Equipment 1.2 Select a Site for Installation 1.2.1 Tabletop 1.2.2 Rack 1.3 Install Your Management Module 1.3.1 Install an Uplink Modu le on the Management Module 1.3.2 Identify the Appropriate Slot for Instal lation 1.
1.0 INSTALLATI ON 1.1 Unpack and Inspect the Equipment The following components should be included: If there is visible damage, do not attemp t to connect the devi ce. Contact Customer Support: customers in Europe, the Middle East and Africa please call 44-0-1635- 570953 or email suppo rt - emea@nettonet.
1.2.2 Rack Using a Phillips Screwdriver, attach the two [2] provided rack mount brackets to the sides of the IPD4000E with eight [8] of the ten [10] provided bracket screws. There are seven posit ion options for the rack brackets; position them as bes t suited to the space available for your chassis on the rack being utilized.
1.3 Install Your Management Module A management module provides the function al control for Net to Net Technologies' IPD4000E; the IPD4000E canno t function without one. Th ere are several different models available for purchase: refer to http://www.
1.3.4 Slide the Management Module Firmly into the Chassis Tighten the fastening screws on the ma nagement module fa ceplate by turning them clockwise with a Phillips screwdrive r.
1.4.2 Align the Interface Module with the Slot Module Guides With the interface module PCB facing UP and the inte rface module model name, and Net to Net logo, on the RI GHT side of the module faceplate (facing towards you), align the left and righ t edges of the PCB with the slot module guides of the chosen slot on the IPD4000E.
1.5.1 Establish a Ground Connection 1.5.1.1 Connect a Ground Wire to the IPD4000E Line up the 2-hole terminal lug of yo ur ground wire with the two holes on the small, unpainted section on the back of your chassis. Secure the terminal lug to the chassis with two #10-32 screws.
1.5.3 Establish a Power Connection 1.5.3.1 Connect Your Positive Power Lead t o the Terminal Block Using a Phillips Screwdriver, remove the upper screw from the chosen terminal block (labeled "+ " on the cha ssis).
1.5.3.3 Connect Both Power Leads to a Fuse Panel The negative (-) lead connects to a "Ba tt" (Battery) terminal and the positive (+) lead connects to a "Return" te rminal on your DC power supply. 1.5.4 Verify the Connection Turn your power source(s) on .
1.7 Connect Your Subscriber Lines The IPD4000E chassis supports ADSL, IDSL, SDSL and T1 /E1 technologies. Ensure that the subscriber lines you are connecting correspond with the technology of the interface module(s) insta lled in your IPD4000E.
1.7.2 Detach the Velcro Strap Detach the Velcro Strap from the female RJ21 connector port: lift the Velcro tab from the bottom and pull the strap upward to open, leaving it looped under the right side of the connector frame.
Tuck the tab at the end of the strap down between the connector frames so that it is out of the way of other connections. Screw the right side of the RJ21 cable connector into the jack screw on the right side of the RJ21 connector frame on the chassis.
http://www.nettonet.com/support/docs for specific information such as connector pinouts, parameter configur ations and distance capabilities. 1.8 Secure the Connecting Cables Position all connecting cables such that they will not beco me a tripping hazard or pull loose from the chassis; secure wi th cable ties or velcro straps.
3.0 ADDITIONAL INFORMA TION 3.1 Fan Module The IPD4000E fan module is in stalled vertically to the ri ght of the interface module slots. It comes pre-installed and should not be removed unless it is being replaced.
Frequently Asked Questions Net to Net Enterprise MIBs Product Discontinuation Notices Product Documentation Visio Network Diagram Stencils 3.3.2 Technical Support Engineers If you are unable to locat e the answers to your questions onlin e, please contact Net to Net Technologies' Technica l Support Department directly: 3.
limits are designed to provide reas onable protection against harmful interference when the equi pment is op erated in a commercial environment. This equipment generates, uses and ca n radiate radio f requency energy and, if not installed and used in accordan ce with the instruction manual, may cause harmful interference to radio communications.
デバイスParadyne IPD4000Eの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Paradyne IPD4000Eをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはParadyne IPD4000Eの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Paradyne IPD4000Eの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Paradyne IPD4000Eで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Paradyne IPD4000Eを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はParadyne IPD4000Eの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Paradyne IPD4000Eに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちParadyne IPD4000Eデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。