Patton electronicメーカー1004Sの使用説明書/サービス説明書
ページ先へ移動 of 10
USER MANU AL SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 Part# 07M1004-C Doc# 04701 1UC Revised 8/10/95 MODEL 1004 and 1004S High Speed, Multipoint Short Range Modem.
1.0 WARRANTY INFORMA TION Patton Electronics warrants all Model 1004 components to be free from defects, and will—at our option—repair or replace the prod- uct should it fail within one year from the first date of shipment.
3.0 CONFIGURA TION The Model 1004 is configured using six PC board mounted switch- es. Figure 1 shows the switch locations, along with the location of the terminal blocks and optional surge protectors: 3.1 SETTING THE DCE/DTE SWITCH For your convenience, the Model 1004 has an externally accessi- ble DCE/DTE switch (Figure 2).
3.2.1 SWITCH SETTINGS All possible settings for the Model 1004’s configuration switches are presented in the summary table below . If you have additional questions, contact T echnical Support at (301) 975-1000.
4.0 INST ALLA TION Once the Model 1004 is properly configured, it is ready to connect to your system. This section tells you how to properly connect the Model 1004 to the twisted pair and RS-232 interfaces, and how to operate the Model 1004.
8. When you finish connecting the wires to the terminal block, the assembly should resemble the diagram below: 9. Place the 2 halves of the strain relief assembly on either side of the telephone wire and press together very lightly . Slide the assem- bly so that it is about 2 inches from the terminal posts and press together firmly .
RJ-45 Cable (4-Wire) SIGNAL PIN# PIN# SIGNAL GND † 2 -----------------------7 GND † RCV- 3 -----------------------5 XMT- XMT+ 4 -----------------------6 RCV+ XMT- 5 -----------------------3 RCV- R.
Figure 4 shows how to wire the two-pair cables properly for a Model 1004 star topology . Note that the ground connection is not needed. 4.2.2 DAISY CHAIN TOPOLOGY Using a daisy chain topology , you may connect several Model 1004s together in a master/slave arrangement.
APPENDIX A SPECIFICA TIONS T ransmission Format: Asynchronous Data Rate: Up to 1 15,200 bps T ransmit Line: 2, 4 wire unconditioned twisted pair T ransmit Mode: Full or half duplex T ransmit Level: 0 .
APPENDIX C BLOCK DIAGRAM 17.
デバイスPatton electronic 1004Sの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Patton electronic 1004Sをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPatton electronic 1004Sの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Patton electronic 1004Sの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Patton electronic 1004Sで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Patton electronic 1004Sを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPatton electronic 1004Sの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Patton electronic 1004Sに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPatton electronic 1004Sデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。