Patton electronicメーカー1060 AC Poweredの使用説明書/サービス説明書
ページ先へ移動 of 10
USER MANUAL MODEL 1060 AC Powered, Asynchronous Short Range Modem SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www .patton.com Part #07M1060-C Doc. #05801 1C Revised 1 1/3/97 CERTIFIED An ISO-9001 Certified Company Dear V alued Customer , Thank you for purchasing Patton Electronics products! W e do appreciate your business.
1.0 W ARRANTY INFORMA TION Patton Electronics warrants all Model 1060 components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of shipment.
2.0 GENERAL INFORMA TION Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warranted for One Y ear parts and labor .
Control Input (C in ): The Control Input signal is used by the local Model 1060 as an input signal to activate its transmitter (“Enabled” settings) and allow data transmission to the remote device. This is required for half-duplex/ switched-carrier environments as well as in hardware flow control applications.
4.0 INSTALLATION The Model 1060 is easy to install. After configuring the DIP switches and DCE/DTE switches, connect the two twisted pairs using one of two methods: terminal blocks or RJ-1 1 jack. Figure 2 (below) shows the location of the terminal blocks and RJ-1 1 jack, as well as the female DB-25, on the rear of the Model 1060.
4.2 WIRING FOR MUL TIPOINT CIRCUITS The Model 1060 supports multi-point applications using either a star or daisy chain topology . Both topologies require special wiring, as well as specific DIP switch settings for master and slave units.
5.2.2 REMOTE ANALOG LOOP The second test mode is Remote Analog Loop. T o enter this mode, set one of the Model 1060s (local) in test mode by depressing the "Loopback T est" switch. Any characters sent from the remote 1060 will be returned to it (see Figure 5).
14 13 APPENDIX A P A TTON MODEL 1060 SPECIFICA TIONS T ransmission Format : Asynchronous T ransmission Line : 19 to 26 A WG twisted pair Range : (See table on page 14) Serial Interface : EIA RS-232 (CCITT V .
15 16 APPENDIX C P A TTON MODEL 1060 INTERF ACE PIN ASSIGNMENTS 1- (FG) Frame Ground 2- (TD) T ransmit Data T o Model 1060 3- (RD) Receive Data From Model 1060 4- (RTS) Request to Send T o Model 1060 .
17 18 APPENDIX E TROUBLESHOOTING SYMPTOM PROBLEM SOLUTION "TD" and "RD" LEDs indicate activity , but units will not communicate or data is garbled "TD" and "RD" LEDs indicate activity , but "CD" LED is unlit or red (should be green) Occasional data errors 1.
デバイスPatton electronic 1060 AC Poweredの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Patton electronic 1060 AC Poweredをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPatton electronic 1060 AC Poweredの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Patton electronic 1060 AC Poweredの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Patton electronic 1060 AC Poweredで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Patton electronic 1060 AC Poweredを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPatton electronic 1060 AC Poweredの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Patton electronic 1060 AC Poweredに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPatton electronic 1060 AC Poweredデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。