Patton electronicメーカー1094の使用説明書/サービス説明書
ページ先へ移動 of 13
USER MANU AL MODEL 1094 KiloModem-768 TM High Speed Baseband Modem SALES OFFICE (301) 975-1000 TECHNICAL SUPPOR T (301) 975-1007 http://www .patton.com P ar t# 07M1094-C Doc# 032031UC R evised 04/13/9.
1 2 1.0 W ARRANTY INFORMA TION P atton Electronics warrants all Model 1094 components to be free from def ects, and will—at our option—repair or replace the product should it f ail within one year from the first date of shipment.
3 4 2.0 GENERAL INFORMATION Thank you f or your purchase of this P atton Electronics product. This product has been thoroughly inspected and tested and is warrant- ed f or One Y ear parts and labor .
5 6 3.1.1 Switch Set S1 The configuration s witches on S1 set clock source, R TS/CTS dela y , carrier control, loopback tests. The default settings are summa- rized in the table abo ve. Switches S1-1 and S1-2: Clock Sour ce Switches S1-1 and S1-2 are set in combination to determine the source of timing f or the Model 1094.
7 8 Switch S1-8: V .54 Enable / Disable The setting f or s witch S1-8 determines whether the Model 1094 will respond when it receives the V .54 sequence. If you suspect the Model 1094 ma y be getting tricked into the loopbac k test by f alse detection of user data, you can try setting this to “Disab le.
9 10 When connecting two Model 1094’ s, it is necessary to use a crosso ver cable. The diagram belo w shows ho w a crossov er cable should be constructed.
11 12 4.2.2 CONNECTION T O A “DTE” DEVICE The serial por t on most QuickConnect™ interface modules (all e xcept the X.21 module) is hard-wired as a DCE.
13 14 5.0 OPERA TION Once the Model 1094 is properly configured and installed, it should operate transparently . This sections describes power-up , read- ing the LED status monitors, and using the b uilt-in loopback test modes. 5.1 PO WER-UP Bef ore applying power to the Model 1094, first be sure that y ou hav e read Section 4.
15 16 B. V er ify that the data ter minal equipment is operating properly and can be used f or a test. If a f ault is indicated, call a technician or replace the unit. C . P erf or m a BER (bit error rate) test on each unit using a separate BER tester .
17 18 5.3.4 V .52 BER TEST GENERA T OR The Model 1094 has a built-in test pattern generator and detector . It can be inv oked at both ends of a link simultaneously or it can be used with the Local Analog or Remote Digital Loopbacks .
19 20 APPENDIX B P A TTON ELECTR ONICS MODEL 1094 CABLE RECOMMEND A TIONS The P atton Model 1094 operates at frequencies of 512 kHz or less and has been perf ormance tested by P atton technicians using twisted-pair cable with the f ollowing characteristics: Wire Gaug e Capacitance Resistance 19 A WG/0.
21 22 APPENDIX D P A TTON ELECTR ONICS MODEL 1094 INTERF ACE PIN ASSIGNMENTS RS-232, RS-530 Interface Pin Description (DB-25 Female Connector) (DCE Configuration) Pin # Signal 1 FG (F rame Ground) 2 T.
23 APPENDIX D P A TTON ELECTR ONICS MODEL 1094 INTERF ACE PIN ASSIGNMENT (Continued) X.21 Interface (DB-15 Female Connector) (DTE /DCE Configuration) Pin # Signal 1 . . . . . . . . . . . . Fr ame Ground 2 . . . . . . . . . . . . T (T ransmit Data-A) 3 .
デバイスPatton electronic 1094の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Patton electronic 1094をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPatton electronic 1094の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Patton electronic 1094の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Patton electronic 1094で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Patton electronic 1094を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPatton electronic 1094の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Patton electronic 1094に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPatton electronic 1094デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。