Patton electronicメーカー1094Aの使用説明書/サービス説明書
ページ先へ移動 of 17
USER MAN U A L MODEL 1094A NetLink™ HDSL Multi-Rate Symmetric DSL Modem Part# 07M1094A-B Doc# 032042UB Revised 07/22/99 SALES OFFICE (301)975-1000 TECHNICAL SUPPO R T (301)975-1007 http://ww w .
T T A A B B L L E E O O F F C C O O N N T T E E N N T T S S SECTION P AGE 1.0 W arranty Information .............................................................2 1.1 Radio and TV Interference 1.2. CE Notice 1.3 Service 2.0 General Information .......
1.3 SERVICE All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container . This number may be obtained from Patton Electronics T echnical Service at: T el: (301)975-1007 Email: support@patton.
3 3 . . 0 0 C C O O N N F F I I G G U U R R A A T T I I O O N N The Model 1094A is equipped with three sets of eight DIP switch- es, which allow configuration of the unit for a wide variety of applica- tions. This section describes switch locations and explains all possible configurations.
7 Switches S2-6 and S2-7: Clock Mode Use Switches S2-6 and S2-7 to configure the 1094A for internal, external, or receive recover clock mode. Switch S2-8: Enable/Disable Loop T ests from DTE Use Switch S2-8 to allow Model 1094A to enter loopback tests when the DTE raises the appropriate loop request pin.
9 Switch S3-7: Reset Software Defaults Switch S3-7 allows the user to reset the software configured facto- ry defaults. S3-7 Factory T est On Normal Operation Off Reset Switch S3-8: T ransmit Data (TD) Sampling Point Switch 3-8 controls the T ransmit Data (TD) sampling point.
11 4.2 CONNECTING THE SERIAL PORT The serial port interface on the Model 1094A uses interchange- able QuikConnect™ Modules. Each QuikConnect™ Module has a 50-pin card edge connector on one side and a serial port interface on the other . Figure 4 below shows how a QuikConnect™ Module plugs into the back of the Model 1094A.
4.2.4 Configuring the X.21 QuikConnect™ Module The serial port on the X.21 QuikConnect™ Module is default wired as a DCE, but may be switched to a DTE. This is done by reversing the orientation of the DCE/DTE strap, as described below: T o reverse DCE/DTE orientation, remove the module according to the instructions in Section 4.
5 5 . . 0 0 O O P P E E R R A A T T I I O O N N Once the Model 1094A is properly configured and installed, it should operate transparently . This sections describes power-up, read- ing the LED status monitors, and using the built-in loopback test modes.
Framer The framer is used to determine the status of the line. In normal operation the framer trans- mits and expects to receive framed packets from the far end. If the framer receives framed packets from the far end, CTS and CD will be active. If framed packets are not received, CTS and CD will be inactive.
5.3.2 Loops and Patterns The following section describes the T est Modes used in the Model 1094A. At the bottom of each T est Mode, a figure is included to show the data path. Local Loop There are two different modes of operation for a Local Loop depending on the status of the units at the time that the Local Loop is initiated.
Local Loop After the 51 1/51 1E pattern times out, the ER led with 51 1/51 1E will begin flashing. It will remain this way until (continued) the pattern generator switch is turned off. Note that the data at the local DTE and the remote DTE are not valid.
Remote Digital The Remote Digital Loop with 51 1/51 1E is Loop with shown above. After RDL is established the 51 1/51 1E Remote units' Restart T imer is set to one minute. This has been done because when the 51 1/51 1E generator is started on the local unit, the Remote framer begins seeing unframed packets.
5.3.3 Using the V .52 (BER) T est Pattern Generator T o use the V .52 BER tests in conjunction with the Remote Digital Loopback tests (or with Local Line Loopback tests), follow these instructions: 1. Locate the “51 1/51 1E” toggle switch on the front panel of the 1094A and move it UP .
A A P P P P E E N N D D I I X X B B P A TTON ELECTRONICS MODEL 1094A F ACTOR Y REPLACEMENT P ARTS AND ACCESSORIES Patton Electronics Model # Description IM1/A ...............................V .24 with DB25F IM1/B ...............................RS422/RS530 with DB25F IM1/C .
A A P P P P E E N N D D I I X X C C P A TTON ELECTRONICS MODEL 1094A INTERF ACE PIN ASSIGNMENTS (Continued) V .35 Interface (M/34F Female Connector) (DCE Configuration) Pin # Signal B ...........................SGND (Signal Ground) C .................
A A P P P P E E N N D D I I X X D D P A TTON ELECTRONICS MODEL 1094A TRANSMISSION DIST ANCES Copyright © 1999 Patton Electronics Company All Rights Reserved 31 Line Rat e DTE Rates kbps feet m iles km feet miles km 144 64, 128 20700 3.9 6.2 24500 4. 6 7.
デバイスPatton electronic 1094Aの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Patton electronic 1094Aをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPatton electronic 1094Aの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Patton electronic 1094Aの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Patton electronic 1094Aで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Patton electronic 1094Aを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPatton electronic 1094Aの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Patton electronic 1094Aに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPatton electronic 1094Aデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。