CM9760-VCRC-P VCR Contr oller Installation/ Operation Manual C1943M (9/99) Pelco • 3500 Pelco Way • Clovis, CA 93612-5699 USA • www.pelco.com In North America and Canada: Tel (800) 289-9100 or F.
2 P elco Manual C1943M (9/99) CONTENTS Section Page IMPORT ANT SAFEGUARDS AND W ARNINGS ................................................................ 3 DESCRIPTION ....................................................................................
P elco Manual C1943M (9/99) 3 IMPORT ANT SAFEGUARDS AND W ARNINGS Prior to installation and use of this product, the following W ARNINGS should be obser v ed. 1. Installation and servicing should only be done by qualified service personnel and con- form to all local codes.
4 P elco Manual C1943M (9/99) MODELS CM9760-VCRC-P VCR control unit capable of controlling 64 VCRs per unit. VCR control is specific to P elco TLR2096 .
P elco Manual C1943M (9/99) 5 DIP SWITCHES With the front panel remov ed, DIP switch 1 and DIP s witch 2 are visible . These two ten-position DIP switches configure and define man y functions of the CM9760-VCRC-P . Figure 3 identifies the relativ e locations of DIP s witches 1 and 2.
6 P elco Manual C1943M (9/99) REAR VIEW The rear of the unit is illustrated in Figure 4. F rom left to right are the following: 1 . The four 16-input b locks of VCR connectors in the form of screw-type connectors with associated mating plugs (one shown in Block 1) running from the left rear to middle right of the unit 2.
P elco Manual C1943M (9/99) 7 INPUT VCR CONNECTORS Physically , each of the four VCRC-P input connectors consists of the same number of input screw-type terminals. Each input group uses a dual-row removable plug and each plug is associated with 8 VCR inputs.
8 P elco Manual C1943M (9/99) RELA Y OUTPUT CONNECTOR Figure 6 illustrates the rela y output connector and its relative por t pin assignments . The connector is a three-position plug with screw-type contacts similar in operation to the mat- ing connectors just discussed.
P elco Manual C1943M (9/99) 9 DB-9 Connector Pin-outs The DB-9 connector is reserved for f actor y use only . RJ-45 Connector RJ-45 connector pin-outs are illustrated in Figure 7. Because both RJ-45 connectors have the same wiring pin-outs, they require the same “flipped” cable.
10 P elco Manual C1943M (9/99) POWER CONNECTIONS The CM9760-VCRC-P utilizes an auto-ranging internal transf or mer circuit that allows the in- put power to r ange from 100-240 V AC @ 50/60 Hz. Associated with the input pow er is the pow er ON/OFF switch and the input po wer fuse.
P elco Manual C1943M (9/99) 11 SETUP PRELIMINAR Y DISCUSSION The CM9760-VCRC-P enables automatic control (via macro e xecution) or man ual control (from the CM9760-KBD) of sev en predefined VCR functions. Each VCRC-P can control up to 64 VCRs. VCR control is implemented by associating System 9760 GPIs to VCRs.
12 P elco Manual C1943M (9/99) Figure 10. DIP Switch Functions NOTE: POSITIONS 9 AND 10 ARE NOT USED AND SHOULD BE LEFT IN THE F ACT ORY DEF A UL T “OFF” POSITION.
P elco Manual C1943M (9/99) 13 SOFTW ARE SETUP–USING THE MGR PROGRAM TO CONFIGURE VCRC-P OPERA TION The VCRC-P unit controls up to 64 VCRs per unit and provides se ven basic functions of VCR control direct from the CM9760 ke yboard. These controls include Stop , Pause , Play , Eject, F ast Forward, Re wind, and Record.
14 P elco Manual C1943M (9/99) 7 . This brings up the GPI SETUP file dialog box (.GPI file). Refer to Figure 12. 8. Program logical GPI numbers f or all the physical numbers that will be used. The ph ysi- cal GPI numbers correspond to a specific VCR control signal on the VCR controller .
P elco Manual C1943M (9/99) 15 Figure 13. Configuring the COMMS file for VCRC-P Operation 10 . Define operator access, sa ve the GPI file, return to the MGR main menu screen and press the tab to bring up the COMMS file (.SCP file). Refer to Figure 13.
16 P elco Manual C1943M (9/99) INST ALLA TION Physical installation of the VCRC-P unit is relatively simple, although various configurations are possible. DIRECT RACK-MOUNT HOOK-UP Regardless of the location of a VCRC-P unit, it will more than likely be installed in a rack (refer to Figure 14).
P elco Manual C1943M (9/99) 17 OPERA TIONAL OVERVIEW The basic function of the VCRC-P unit is to act as an interface between the user/operator of the system and any connected VCRs. Each VCRC-P processes and executes only com- mands with addresses that match the controller address.
18 P elco Manual C1943M (9/99) OPERA TING THE CM9760-VCRC-P FROM THE CM9760-KBD Direct control operation of VCRs attached to VCRC-Ps from a CM9760-KBD is relatively straightf orward. Once the system is running and the ke yboard is online, direct control of a VCR is as follows: 1.
P elco Manual C1943M (9/99) 19 SPECIFICA TIONS Electrical Input V oltage: Auto-r anging 100-240 V AC , 50/60 Hz P o wer: Consumption: 30 vA Data P or ts Input: RS-422, RJ-45 connector DIP switch selectable baud rate Output: RS-422, RJ-45 connector .
20 P elco Manual C1943M (9/99) P elco, the P elco logo, Camclosure, Esprit, Gene x, Legacy , System 9760, and Spectra are registered trademarks of P elco. © Cop yr ig ht 1999, P elco. Endura and ExSite are trademarks of P elco. All rights reser v ed.
デバイスPelco c1943mの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Pelco c1943mをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPelco c1943mの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Pelco c1943mの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Pelco c1943mで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Pelco c1943mを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPelco c1943mの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Pelco c1943mに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPelco c1943mデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。