® INST ALLA TION F T82011/FR82011 Ethernet Media Converter One 10BASE-T/100BASE-TX Port and One 100BASE-FX Fiber Port C2653M (6/07).
.
C2653M (6/0 7) 3 Contents Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Regulatory Not ices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 C2653M (6/07) Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water . 6. Clean only with dry cloth. 7. Do not block any ventilation openings.
C2653M (6/0 7) 5 The product and/or manual may bear the following marks: This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit. This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
6 C2653M (6/07) Regulatory Notices This device complies with Part 15 of the FCC Rule s. Operation is subject to the following two conditions: (1) this device may not cause harmful in terference, and (2) this device must accept any interference received, including interfer ence that may cause undesired operation.
C2653M (6/0 7) 7 Product Overview DESCRIPTION The F T82011/FR82011 Ethernet media co nverter co n ve r ts 10 B AS E -T / 100BASE-TX data to 100BASE-FX data and vice versa. Designed for point -to-point applica tions, the F T82011/F R 82011 me d ia c on v er t er provides one 10BASE-T/100BASE-TX port and one 100BASE-FX fiber port.
8 C2653M (6/07) • Compatible with ot her Ethernet equipment: – 10BASE-T/100BASE-TX compat ibility with all Pelco © and third-pa rty 10BASE-T/ 100BASE-TX Ethernet devices – Fiber optic compatibi.
C2653M (6/0 7) 9 MODELS The F T82011 and FR82011 modules consist of the following se ries of models: Multimode Models:* F T82011MSTR-1 Ethernet media converter , one 10 BASE-T/100BASE-T X port, one mu.
10 C2653M (6/07) FRONT PANEL Figure 2 illustrates the front panel of the F T82011 and FR82011 modules. Figure 2. Front Panel of F T82011 and FR82011 Modules For detailed information about the front-panel LEDs, refer to the T roubleshooting section.
C2653M (6/0 7) 11 REAR PANEL Figure 3 illustrates the rear pa nel of the F T82011 and FR82011 modules. Figure 3. Rear Panel of F T82011 and FR82011 Mo dules (SC Fiber Connector Shown) For additional informati on about rear -panel connections, refer to the Installation section.
12 C2653M (6/07) Installation PACKAGE CONTENTS The following it ems are supplied: 1 F T82011 or FR82011 module 1 Regulated switching power suppl y with four plug adapt ers (North American, Australian, U.K., and European configurations); 100-240 V A C, 50-60 Hz input, 12 VDC output 1 Wall clip with two 4 -40 x 0.
C2653M (6/0 7) 13 Using the TX Mode switch, you can do the following: • Enable autonegotiation or select (force) a specific data rate and duplex mode: – Enabling autonegotiation allows the F T8201.
14 C2653M (6/07) MOUNTING The F T82011/FR82011 module can be mounted into a ra ck or can be used as a stand-alone module. As a stand-alone module, the un it can be placed on a desktop or can be mounted to a wall.
C2653M (6/0 7) 15 Mounting the F T82011/FR82011 Module Using the Wall Clip NOTE: Before mounting the F T82011/FR82011 module to a wall, ensure that there is adequate space at both ends for viewing the front-panel LEDs and for making the various rear-pa nel cable connections.
16 C2653M (6/07) CONNECTIONS Connections to the F T82011/FR82011 module are made on the rear panel of the unit (refer to Figure 6). Figure 6. F T82011/FR82011 Module Connecti ons As illustrated in Fig.
C2653M (6/0 7) 17 • Fiber connection NOTE: Fiber port A of the F T82011 module connects to fiber port B of the FR82011 module or of any other Pelco Ethernet sw itch that supports wavelength division multiplexing (WDM).
18 C2653M (6/07) T roubleshooting LED indicators on the front and rear panels of the F T82011/FR82011 module allow you to monitor operational status: • LED indicators on the front panel allow you to monitor operating power , 100BASE-FX port status, and optic signal/l aser status.
C2653M (6/0 7) 19 100BASE-FX Status LED ( ) (Continued) Red Ethernet link is down. NOTE: In addition to a red 100BASE-FX Status LED, the Optic Fault LED is green or flashing red and the left RJ-45 Port Status LED (Link/Activity) is not lit .
20 C2653M (6/07) Optic Fault LED ( ) (Continued) Red Ethernet link is down. NOTE: In addition to a red Optic Fault LED, the 100BASE-FX LED and the left RJ-45 Port Status LED (Link/Activity) LED are not lit.
C2653M (6/0 7) 21 Optic Fault LED ( ) (Continued) Flashing red Ethernet link is down. NOTE: In addition to a flashing red Optic Fault LED, the 100BASE-FX LED is red and the left RJ-45 Port Status LED (Link/Activity) LED is not lit.
22 C2653M (6/07) T able C. T roubleshooting with Rea r-Panel Indicators Indicator Color Meaning Possible Cause Corrective Action RJ-45 10BASE-T/100BASE-TX Port St atus LED - Left (Link/Activity) Amber A 10BASE-T link is estab- lished. — If 10BASE-T operation is desired, no action is required.
C2653M (6/0 7) 23 RJ-45 10BASE-T/100BASE-TX Port Status LED - Left (Link/Activity) (Continued) Not lit Ethernet link is down. A link-down det ection condition exists due to any of the following fault .
24 C2653M (6/07) RJ-45 10BASE-T/100BASE-TX Port Stat us LED - Right (Duplex/Co llision) Amber Port is set to 10BASE-T full-duplex mode. — If 10BASE-T full-duplex operation is desired, no action is required.
C2653M (6/0 7) 25 RJ-45 10BASE-T/100BASE-TX Po rt Status LED - Right (D uplex/Collision) (Continued) Green Port is set to 100BASE-TX full-duplex mode. — If 100BASE-TX full-duplex operation is desired, no action is required.
26 C2653M (6/07) RJ-45 10BASE-T/100BASE-TX Po rt Status LED - Right (D uplex/Collision) (Continued) Not lit Por t is set to 10BASE-T half-duplex mode and no collisions are detected.* — If 10BASE-T half-duplex operation is desired, no action is required.
C2653M (6/0 7) 27 Specifications PERFORMANCE Switch T ype Unmanaged Layer 2 Switch Method Store and forward Data Rate 10/100 Mbps Compliance IEEE 802.3, 802.3u, 802.3x Interface Auto MDI/MDI-X Operating Mode Full- duplex or half-duplex Address T able Size 1,024 MAC address ent ries with automatic learning and aging Quality of Service IEEE 802.
28 C2653M (6/07) OPTICAL POWER BUDGET AND MAXI MUM TRANSMISSION DIST ANCE Model Number Wavelength (T ransmit/Receive)* Optical Power Budget Maximum T ransmission Distance T ransmitter End Receiver End Fiber Port A Fiber Port B Multimode (62.5/125 μm) F T82011MSTR-1 FR82011MSTR-1 1310/850 nm 850/1310 nm 26 dB † 2 km (1.
C2653M (6/0 7) 29 Appendix. RJ-45 Connector Pinouts Figure 7 illustrates RJ-45 MDI/MDI-X connector pinouts. Figure 7. RJ-45 MDI/MDI-X Connector Pinouts T able D summarizes RJ-45 MDI/MDI-X connector pinouts.
30 C2653M (6/07) The materials used in the manufacture of this document and its components are compliant to t he requirements of Directive 2002/95/EC. This equipment contains electrica l or electronic.
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merc handise pr oved defective in mate rial or work manship for a period of one year after the date of shipment.
® Worl dwide Headquarters 3500 Pelco W ay Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .
デバイスPelco FR82011の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Pelco FR82011をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPelco FR82011の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Pelco FR82011の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Pelco FR82011で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Pelco FR82011を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPelco FR82011の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Pelco FR82011に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPelco FR82011デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。