PelcoメーカーMC3710の使用説明書/サービス説明書
ページ先へ移動 of 24
Installa tion/Oper a tion MC3610 and MC3710 Series Black-W hite Camer a C2913M-F (08/05) Pelco Worldwide Headquarters • 3500 Pelco Way, Clovis, CA 93612-5699 USA • www.
[ 2 ] Pelco Manual C2913M-F (08/05) ® Pelco, the Pelco logo, Spectra, Genex, Legacy , Esprit and Camclosure are registered trademarks of Pelco. ™Endura and ExSite are trademarks of Pelco ™DLP is a trademark of T exas Instruments, Inc. ™SuperHAD CCD is a trademark of the Sony Corporation.
Pelco Manual C2913M-F (08/05) [ 3 ] CONTENTS IMPORT ANT SAFETY INSTRUCTIONS ........................................................................................................... 4 REGULA TORY NOTICES .............................................
[ 4 ] Pelco Manual C2913M-F (08/05) This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit. This symbol indicates that there are impor- tant operating and maintenance instructions in the literature accompanying this unit.
Pelco Manual C2913M-F (08/05) [ 5 ] REGULA T OR Y NOTICES This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
[ 6 ] Pelco Manual C2913M-F (08/05) INST ALLA TION Lens Mounting MC3610 and MC3710 Series cameras can use fixed iris, manual iris, auto iris, or direct drive lenses. Cameras are factory-set for CS-mount lenses, but are easily adjusted for C-mount lenses.
Pelco Manual C2913M-F (08/05) [ 7 ] Camera Mounting Mounting points are provided on the top and bottom of the camera and are used to mount the camera on a bracket or tripod. They are designed to accept standard photographic mounting bolts (1/4-inch UNC-20).
[ 8 ] Pelco Manual C2913M-F (08/05) P ower Connections MC3610 and MC3710 Series cameras are available in AC high voltage and AC/DC low voltage types. The voltage required to operate the camera is clearly marked on the rear panel of the camera. The green POWER LED on the rear panel indicates that power is connected.
Pelco Manual C2913M-F (08/05) [ 9 ] EXAMPLE: A camera that requires 5 V A and is installed 224 feet (68 m) from the transformer would require a minimum wire gauge of 24 AWG. T able B. Wiring Distances for 5 V A Cameras (24 V AC/12 VDC) The following are the recommended maximum distances for low voltage cameras.
[ 10 ] Pelco Manual C2913M-F (08/05) Genlock Connection (MC3710H Series Only) Genlock (short for generator lock) is a system that allows the synchronization of two or more cameras to a specific timing signal.
Pelco Manual C2913M-F (08/05) [ 11 ] RJ45-10 Connections The RJ45-10 connector allows video (composite and twisted pair except MC3710S models) and power connections to be made to the camera using a single Cat5-style cable. NO TE: The PCM150 camera mount is designed for the MC3610 and MC3710 Series camera.
[ 12 ] Pelco Manual C2913M-F (08/05) Ser vice Connection The service connector allows a video monitor to be connected locally to the camera using a 2.5 mm plug to composite video BNC cable.
Pelco Manual C2913M-F (08/05) [ 13 ] CAMERA SETUP Lens Setup and Focus Procedures Video Drive or Direct Drive (DC) Auto Iris Lens 1. Set the ESC switch and AGC switch to OFF . 2. Adjust the lens for the optimum picture. Video Drive. Refer to the lens instructions and adjust the lens for the optimum picture (video output level of 1 V peak-to-peak).
[ 14 ] Pelco Manual C2913M-F (08/05) Back F ocus Adjustment The back focus adjustment is located at the front of the camera and is accessible from either side of the case. T o adjust the back focus: 1. Loosen the two back focus locking screws (one on each side).
Pelco Manual C2913M-F (08/05) [ 15 ] Figure 9. Switch Settings (White indicates default switch position.) Switch Settings NO TE: Under most conditions, no setting of switches will be required. Please read the details of each switch before making any adjustments.
[ 16 ] Pelco Manual C2913M-F (08/05) Flickerless - Switch Setting 4 The flickerless setting can reduce the flicker caused by certain lighting conditions. The Electronic Shutter Control must be off for the correct operation of the flickerless function.
Pelco Manual C2913M-F (08/05) [ 17 ] Camera Synchronization When using more than one camera power supply , a brief vertical roll may occur on the monitor when a camera view is switched. T o eliminate this vertical roll, it is necessary for the cameras to be synchronized.
[ 18 ] Pelco Manual C2913M-F (08/05) SPECIFICA TIONS GENERAL Imaging Device: 1/3-inch interline transfer CCD Picture Elements MC3710H and MC3610H: EIA 768 (H) x 494 (V); CCIR 752 (H) x 582 (V) MC3710S.
Pelco Manual C2913M-F (08/05) [ 19 ] MECHANICAL Lens Mount: C/CS mount (adjustable) Camera Mount: 1/4–inch UNC-20 screw , top or bottom of camera housing ENVIR ONMENT AL Operating T emperature: 14°.
[ 20 ] Pelco Manual C2913M-F (08/05).
Pelco Manual C2913M-F (08/05) [ 21 ].
[ 22 ] Pelco Manual C2913M-F (08/05) If the goods are to be sent by a FREIGHT FORWARDER, send the goods to: Pelco c/o Expeditors 473 Eccles Avenue South San Francisco, CA 94080 USA Phone: 650-737-1700.
Pelco Manual C2913M-F (08/05) [ 23 ] REVISION HIST ORY Manual # Date Comments C2913M 05/04 Original version. C2913M-A 0 7/04 Lens connector pin out changed. C2913M-B 09/04 Clarified instructions for UTP use. C2913M-C 1 1/04 Added UL warning for high-voltage models.
[ 24 ] Pelco Manual C2913M-F (08/05) Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.pelco.com www.pelco.com www.pelco.com www.
デバイスPelco MC3710の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Pelco MC3710をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPelco MC3710の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Pelco MC3710の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Pelco MC3710で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Pelco MC3710を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPelco MC3710の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Pelco MC3710に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPelco MC3710デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。