PelcoメーカーSS2000の使用説明書/サービス説明書
ページ先へ移動 of 20
SS20, SS22, SS2000, SS2002 Series Discr eet Sur veillance Enclosures Installation/ Operation Manual C429M-B (2/98) Pelco • 300 W. Pontiac Way, Clovis • CA 93612-5699 USA • Pelco Online @ http://www.
2 Pelco Manual C429M-B (2/98) REVISION HISTOR Y Manual # Date Comments C429M-A 10/94 Wire colors revised on figures 2-4, 6 and 7. (Pin 8 - Figure 2; Pins 8 & 23 - Figures 3 and 4; Pins 8, 11, 12, 13 - Figures 6 and 7.) C429M-B 7/96 Revised to include new models SS22 and SS2002-SL.
Pelco Manual C429M-B (2/98) 3 1.0 GENERAL CAUTION: This device is designed to operate at 24 volts AC power . Input volt- ages must not exceed 28 volts or drop below 22 volts, or else damage the the motors will occur . Should you need technical assis- tance, please call (800) 289- 9100.
4 Pelco Manual C429M-B (2/98) 2.0 DESCRIPTION Pelco’ s SS20/SS22/SS2000/SS2002 Series domes are full-sphere, discreet sur- veillance enclosures designed to be suspended from ceilings and to compliment the interior design of businesses, hotels, and offices.
Pelco Manual C429M-B (2/98) 5 3.0 INST ALLA TION Save the shipping carton and plastic packing in case the unit has to be returned for credit or repair . 3.1 CONDUCTOR AND CABLE REQUIREMENTS A minimum of 1 1 conductors plus coax is required, which includes common re- quirements for motorized zoom lens and camera AC power .
6 Pelco Manual C429M-B (2/98) Figure 2 . SS2000/SS2000-SL/SS2002-SL W iring Diagram.
Pelco Manual C429M-B (2/98) 7 Figure 3 . SS2000-PP W iring Diagram.
8 Pelco Manual C429M-B (2/98) Figure 4 . SS2000SL-PP Wiring Diagram.
Pelco Manual C429M-B (2/98) 9 Figure 5 . Connector Assembly 3.2 CONNECTOR ASSEMBL Y T o install and test the SS2000/SS2002 Series dome you will need to assemble the connector parts provided. Fabricate the interconnecting cable as outlined below (see Figure 5): 1.
10 Pelco Manual C429M-B (2/98) 8 4 3 1 14 9 20 15 25 21 28 26 FRONT VIEW 28-PIN CONNECTOR CABLE CLAMP' CON206070-1 CABLE, 12 COND. @ 6' WIR201912 CABLE, 9 COND. @ 6' WIR220709 COAX @ 6' WIRRG174/U CONCPM88-174 28-POS RECEPTACLE CON205839-3 CRIMP SOCKET CON1-66504-0 Figure 6 .
Pelco Manual C429M-B (2/98) 11 3.3 MOUNTING The SS2000/SS2002 enclosure is designed to be suspended from a suitable length of 1-1/2" pipe threaded at both ends. This pipe can be interfaced to either a Pelco MRW A wall adapter , MRCA ceiling adapter, or coupled to a longer length of pipe.
12 Pelco Manual C429M-B (2/98) 3.4 DOME INST ALLA TION T o install your dome system, perform the following steps (refer to Figure 9): 1. Select the appropriate pipe length and mounting method. If the MRCA or MR WA mount is used, tighten the pipe to approximately 30 ft lb, then tighten the 8-32 screw in the pipe nut to lock the pipe threads.
Pelco Manual C429M-B (2/98) 13 4.0 EXPLODED ASSEMBL Y DIAGRAM T able A. SS2000/SS2002 Exploded Assembly Diagram Item Qty Description Part Number 1 1 Dome, upper SS200010000 2 1 Dome, lower, Black (Opa.
14 Pelco Manual C429M-B (2/98) Figure 9 . SS2000/SS2002 Exploded Assembly Diagram.
Pelco Manual C429M-B (2/98) 15 5.0 ADJUSTMENTS T o adjust the pan/tilt limits, perform the following steps. Refer to Figure 10 for limit stop locations. Factory pan limits are set to 0-355 ° and tilt limits are set to 0-90 ° (horizontal to vertical).
16 Pelco Manual C429M-B (2/98) 6.0 MAINTENANCE Clean the acrylic lower dome as necessary to maintain a clear picture. Be careful not to scratch the surfaces of the dome. Exterior Surface - Clean the dome's exterior surface with a nonabrasive cleaning cloth and cleaning agent that is safe for acrylic plastic.
Pelco Manual C429M-B (2/98) 17 7.0 SPECIFICA TIONS ELECTRICAL Input Voltage: 24 VAC required for pan/tilt Running Current Pan: 0.31 amp (7.44 vA) Tilt: 0.
18 Pelco Manual C429M-B (2/98) GENERAL Maximum Camera/ Lens Length: 12.5 inches (31.75 cm) Ambient Temperature Range: 35 ° F to 120 ° F (1.6 ° C to 48.
Pelco Manual C429M-B (2/98) 19 NOTES.
20 Pelco Manual C429M-B (2/98) 8.0 WARRANTY AND RETURN INFORMA TION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Excep- tions to this warranty are as noted below: • Three years on Genex™ Series multiplexers.
デバイスPelco SS2000の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Pelco SS2000をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPelco SS2000の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Pelco SS2000の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Pelco SS2000で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Pelco SS2000を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPelco SS2000の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Pelco SS2000に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPelco SS2000デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。