Rev. A 1-18-06 1 P/N 620001 Hydrel Fixture Housing - Rust Staining Repair Instructions Before installing this product, read and follow all warning notices and instructions accompanying this product. Failure to follow safety warnings and instructions can result in severe injury, death, or property damage.
P/N 620001 2 Rev. A 1-18-06 SECTION I. FIXTURE HOUSING ENTR Y HUB REP AIR INSTRUCTIONS. STEP 1 Before starting repair , ensure that the inside of the fixture housing has the same style entry hub as shown in Figure 1. It is necessary to verify the correct style entry hub for this warranty repair .
Rev. A 1-18-06 3 P/N 620001 Fixtur e Housing Entry Hub Repair Instructions. STEP 2 1. If there is no internal bond wire as shown, skip to STEP 3. 2 . If there is an internal bond wire or a non-listed potting material around the bond post, remove the potting material completely.
P/N 620001 4 Rev. A 1-18-06 Fixtur e Housing Entry Hub Repair Instructions. STEP 3 If there is no internal bond wire in the conduit, the fixture housing will appear as shown in Figure 3. hn-03-11-16-98 No bond wire in conduit unused bond screw . Figure 3.
Rev. A 1-18-06 5 P/N 620001 Fixtur e Housing Entry Hub Repair Instructions. Working with muriatic acid can be dangerous. When cleaning elements always wear rubber gloves and eye protection. Add acid to water, do not add water to acid. Splashing or spilling acid can cause severe personal injury and/or property damage.
P/N 620001 6 Rev. A 1-18-06 Fixtur e Housing Entry Hub Repair Instructions. STEP 5. 1. Attach an anode block, (with an allen head set screw), installed directly to one of the two unused posts on the hub ring. a. This is done by pushing the center hole of the block firmly and completely over the post, press-fitting it into place.
Rev. A 1-18-06 7 P/N 620001 Fixtur e Housing Entry Hub Repair Instructions. STEP 6. 1. After fully pressing the anode block into place, tighten the set screw with a 3/32 inch allen wrench, see Figure 6. a. The allen wrench is not supplied with the kit.
P/N 620001 8 Rev. A 1-18-06 Fixtur e Housing Entry Hub Repair Instructions. STEP 7 1. If a bonding wire is connected to the bonding lug in the fixture housing cover this connection with a listed potting compound, (Scotchcast 2134 or equivelant). a. This will require the pool water level to be lowered and the potted area dried.
Rev. A 1-18-06 9 P/N 620001 SECTION II. AL TERNA TE REP AIR INSTRUCTIONS, BEFORE 1998. This repair procedure can be used both for small fixture housings and for those with angled conduit hubs. STEP 1. Before starting repair , ensure that the inside of the fixture housing has the same style entry hub as shown in Figure 1.
P/N 620001 1 0 Rev. A 1-18-06 Working with muriatic acid can be dangerous. When cleaning elements always wear rubber gloves and eye protection. Add acid to water, do not add water to acid. Splashing or spilling acid can cause severe personal injury and/or property damage.
Rev. A 1-18-06 1 1 P/N 620001 Alternate Repair Instructions STEP 3 1. Attach No. 8 copper jumper wire to one of the two unused posts on the hub ring. a. Place the ring over the post, and press the jumper wire in the gap between the ring and post opposite the ring set screw.
P/N 620001 1 2 Rev. A 1-18-06 Alternate Repair Instructions STEP 4 1. Attach the anode asssembly to the jumper wire using the mechnical lug. 2. Tighten all the screws firmly. 3. Position the anode to clear the light fixture and the cord, and to be away from the entry hub.
Rev. A 1-18-06 1 3 P/N 620001 Alternate Repair Instructions STEP 5 1. Completely cover the entire entry hub, the bond wire and the post clamp with two parts underwater epoxy putty, (supplied with this kit), to at least 1/4 inch thickness.
P/N 620001 1 4 Rev. A 1-18-06 Alternate Repair Instructions STEP 6 If there is no internal bond wire in the conduit, the unused bond screw and hub can be used to attach the jumper wire. hn-03-11-16-98 No bond wire in conduit unused bond screw Figure 6.
Rev. A 1-18-06 1 5 P/N 620001 Alternate Repair Instructions STEP 7 1. Attach the No. 8 copper jumper wire to the unused bond lug and tighten the screw frimly. 2. Attach the anode assembly to the jumper wire using the mechanical lug. 3. Tighten all the screws firmly.
P/N 620001 1 6 Rev. A 1-18-06 Alternate Repair Instructions STEP 8 1. Completely cover the entire entry hub and the jumper wire connection with two parts of underwater epoxy putty, (supplied with this kit), to at least 1/4 inch thickness.
デバイスPentair 620001の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Pentair 620001をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPentair 620001の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Pentair 620001の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Pentair 620001で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Pentair 620001を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPentair 620001の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Pentair 620001に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPentair 620001デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。