Rev. B 1-20-04 1 P/N 472299 MiniMax ® NT Heater Digital Display T emperature Controller (DDTC) Installation Instructions Important Notice Attention Installer. This manual contains important information about the installation, operation and safe use of this product.
P/N 472299 2 Rev. B 1-20-04 SECTION I. INST ALLA TION 1. Turn off the electrical power to the heater. 2. Open the heater’s right door. 3. Disconnect all wires from the 6800 Temperature Controller. 4. Remove the left and right doors from the heater if necessary.
Rev. B 1-20-04 3 P/N 472299 Apply silicone between the gask et and front-mounting frame. Apply silicone between the gask et and rear-mounting frame. Secure DDTC cov er and rain shield by using six scre ws.
P/N 472299 4 Rev. B 1-20-04 GRN IGN MODULE IGNITOR HOT SURFACE BURNER GND VAL TH IGN L2 L1 IGN/240 MiniMax NT LN Dual Voltage W/DDTC Wiring Diagram ORG WHT GRN ORG RED THERMAL FUSE WHT BLU RED SWITCH WATER PRESSURE GAS VALVE RED WHT BLU RED HIGH LIMIT 115˚F 1 2 3 4 5 3 2 1 GRN AIR PRESS.
Rev. B 1-20-04 5 P/N 472299 GRN IGN MODULE IGNITOR HOT SURFACE BURNER GND VAL TH IGN L2 L1 IGN/240 MiniMax NT STD Dual Voltage W/DDTC Wiring Diagram ORG WHT GRN ORG RED THERMAL FUSE WHT BLU RED SWITCH WATER PRESSURE GAS VALVE RED WHT BLU RED HIGH LIMIT 115˚F 1 2 3 4 5 3 2 1 GRN AIR PRESS.
P/N 472299 6 Rev. B 1-20-04 Figure 6. J1 DDTC WATER PRESSURE SWITCH MiniMax NT TSI w/DDTC WIRING DIAGRAM GY AIR PRESSURE SW. O BLOWER O J5 J6 J8 G COM NO R/W R BK/W BK O REMOTE CONTROL MANUAL FOR &.
Rev. B 1-20-04 7 P/N 472299 SECTION III. INTRODUCTION OF DDTC The DDTC board, shown in Figure 7, is a digital temperature controller capable of controlling the pool, spa or both to a minimum temperature of 65° F. (below 65° F. display reads "Off") and a maximum of 104° F.
P/N 472299 8 Rev. B 1-20-04 SECTION IV . SET UP The MiniMax NT Heater comes from the factory preset with a pool temperature setting of 78° F. and a preset spa temperature of 100° F.
Rev. B 1-20-04 9 P/N 472299 • THERMOST A T This light is on when the thermostat contacts close, signaled by the water temperature falling below the set-point, calling for the heater to fire to maintain the desired water temperature.
P/N 472299 10 Rev. B 1-20-04 NOTE: With this type of two-wire remote, with its own temperature sensors and system control, using the up arrows on the front of the DDTC, hold down the up arrow until you reach the maximum setting of 104° F., this allows the remote system thermostat to operate the heater at any set-point below 104° F.
Rev. B 1-20-04 11 P/N 472299 Figure 8..
P/N 472299 12 Rev. B 1-20-04 Pentair Pool Products 1620 Hawkins Ave., Sanford, NC 27330 • (919) 774-4151 10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 523-2400 SECTION X. MINIMAX NT HEA TER DDTC RETROFIT KIT PAR TS SAVE THESE INSTRUCTIONS.
デバイスPentair MiniMax NT Heaterの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Pentair MiniMax NT Heaterをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPentair MiniMax NT Heaterの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Pentair MiniMax NT Heaterの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Pentair MiniMax NT Heaterで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Pentair MiniMax NT Heaterを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPentair MiniMax NT Heaterの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Pentair MiniMax NT Heaterに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPentair MiniMax NT Heaterデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。