ACDelcoメーカーAC-G0003の使用説明書/サービス説明書
ページ先へ移動 of 37
20080303 Model # AC-G0003 5500 Surge Watts / 5000 Running Watts PORTABLE GENERATOR INSTRUCTION MANUAL Thank you for purchasing this high quality ACDelco Model AC -G0003 5500 Surge Watts / 5000 Running Watts Portable Generator.
Model AC-G0003 5500 Surge Wa tts / 5000 Running Watts Portable Gen erator 2 www.buffalotools.com.
ACDelco Model AC-G0003 5500 Surge Watts / 5000 Running Watts Portable Generator FEATURES: • 5500 Surge Output • 5000 Running Watts • 120/240 Volt Operation • 13 HP Engine, 4 Stroke OHV • Air Cooled • 6.
Model AC-G0003 5500 Surge Wa tts / 5000 Running Watts Portable Gen erator 4 TABLE OF CONTENTS RECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS .................................................................................................... 5 IMPORTANT SAFETY INSTRUCTIONS .
RECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS What You Need to Know About Safety Instructions Warning and Important Safety Instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur. Common sense, caution and care must be exercised when operating or cleaning tools and equipment.
Notice Regarding Emissions: Engines certified to comply with California and U.S. EPA emissi on regulations for SORE (Small Off Road Equipment) are certified to operate on regular unleaded gasoline and may include the following emission c ontrol systems: Three-Way Catalyst (TWC) (if equipped), and E ngine Modifications (EM).
Powerful Voltage: This generator produces powerful voltage, which can result in electrocution. • ALWAYS ground this generator before using it. (See “Ground the Generator” section in this manual). • Only electrical devices should be plugged into this generat or, either directly or with an extension cord.
Model AC-G0003 5500 Surge Wa tts / 5000 Running Watts Portable Gen erator 8.
In addition to the previously described safety information, fam iliarize yourself with all safety and hazard placards on this ge nerator. Model AC-G0003 5500 Surge Wa tts / 5000 Running Watts Portable.
PACKAGE CONTENTS The following items are supplied with this ACDelco Model AC -G0003 5500 Surge Watts / 5000 Running Watts Portable Generator. Ver ify that all items are included. STOP! If there are missing items, call 1-866-460-9437, Monday - Friday, 8 AM - 4 PM Central Time for customer service.
GENERATOR COMPONENTS Observe the locations and functions of the various components and controls of this generator. (1) 120/240 Volt AC Outlet - Used for connecting electrical devices that run on 120 and/or 240 Volt, 60 Hz, single phase, AC current. (2) Ground Terminal - Used for connecting grounding wires to properly ground this generator.
PREPARING THE GENERATOR FOR USE Using this Generator for the First-Time STOP! The following section describes the required steps for preparing this generator for the first use. Failure to correctly perform these steps can damage this generator and/or shorten its life.
Step 2 - Add Gasoline Gasoline and gasoline fumes are highly flammable and explosive. Handling fuel can result in serious injury or burns. • Do not fill the fuel tank near a heat, sparks or an open flame. Keep gasoline away from appliance pilot lights, barbecues, el ectric appliances, power tools, etc.
Step 3 - Ground the Generator Failure to properly ground this generator can result in electrocution. Ground this generator by tightening the grounding nut against a groundi ng wire as illustrated in Figure 3. A No. 12 AWG (Americ an Wire Gauge) stranded copper wire is generally an acceptable grounding wire.
Step 2 - Verify Gas Level Before starting this generator, verify that there is sufficient gasoline in the fuel tank. The fuel gauge, located on the top o f this generator, indicates the gas level currently in the fuel tank.
6. Slowly pull on the recoil starter handle, shown in Figure 6, until a slight resistance is felt. Then pull briskly to start t he engine. Gently return the cord into the generator to avoid damage to the starter or housing. Never allow the cord to snap back.
The total running wattage requirement of the electrical devices connected to a generator should not exceed the rated wattage of the generator itself. To calculate the total wattage requirement of the .
Connect only electrical devices that are in good working order. Faulty devices or power cords present the risk of electrical sh ock. Immediately turn off and disconnect any d evice that commences to operate abnormally, sl uggish or abruptly stops.
DC Usage The DC outlet is only for recharging 12 Volt automotive-type batteries. Do not connect any other device to this outlet. Use this generator only for recharging 12 Volt batteries. NEVER attempt to jumpstart a car with this generator. Failing to use the correct procedure can cause a battery to explode , seriously injuring anyone nearby.
MAINTENANCE/CARE Proper routine maintenance of this generator is essential fo r safe, economical, and trouble-free operation. It will help prolon g the life of this generator as well as help reduce air pollution. Perform maintenance c hecks and procedures according to the schedule in Figure 10.
Figure 11 - Checking the Oil Changing/Adding Oil The oil level in this generator should be checked before each us e. (See Figure 10.) When the oil level is low, add oil until th e level is sufficient to operate this generator. The oil capacity for this ACDelco Model AC-G0003 5500 Surge Wa tts / 5000 Running Watts Portable Generator engine is 1.
Figure 12 - Draining Oil Figure 13 - Adding Oil Air Filter Maintenance Routine maintenance of the air filter helps maintain proper airflow to the carburetor. Occasionally verify that the air filter is free of excessive dirt. The air filter will require more frequent cleaning when oper ating this generator in extremely dusty areas.
3. Using a rag or brush, clean the cup of all sediment. 4. Reinstall the fuel filter cup. Figure 15 - Removing the Fuel Filter Cup Spark Plug Maintenance The spark plug is essential for proper engine operation. The spark plug should be intact, free of deposits, and properly gapped.
Figure 16 - Removing the Spark Plug Figure 17 - Measuring the Spark Plug Gap Emptying the Fuel Tank To store this generator for extended time, drain the gasoline from the fuel tank. To drain gasoline from this generator: 1. Turn the fuel valve to the “off” position.
Model AC-G0003 5500 Surge Wa tts / 5000 Running Watts Portable Gen erator 25 TROUBLESHOOTING IMPORTANT: If trouble persists, call our customer help line at 1-866-460-9437, M onday - Friday, 8 AM - 4 PM Central Time. Symptom Cause Solution Engine switch is set to "off.
Model AC-G0003 5500 Surge Wa tts / 5000 Running Watts Portable Gen erator 26 SPECIFICATIONS ACDelco Model AC-G0003 5500 Surge Watts / 5000 Running Watts Portable Generator Generator Type Brush, Revolv.
EXPLODED VIEW AND PARTS LIST Model AC-G0003 5500 Surge Wa tts / 5000 Running Watts Portable Gen erator 27.
Model AC-G0003 5500 Surge Wa tts / 5000 Running Watts Portable Gen erator 28 PARTS LIST Item Part Qty Descri ption Item Part Qty Description 1 188FD 1 Gasoline engine 50 37880 1 Low oil indicator 2 41100 1 F rame complete 51 37310/ 2.8GF-3 1 Control panel 3 41310/4GF-3 2 Bottom rubber mount A 52 37320 1 Block panel 4 41320/2.
MODEL AC-G0003 5500 SURGE WATTS / 5000 RUNNING WATTS PORTABLE GENERATOR WIRING DIAGRAM Model AC-G0003 5500 Surge Wa tts / 5000 Running Watts Portable Gen erator 29.
Model AC-G0003 5500 Surge Wa tts / 5000 Running Watts Portable Gen erator 30 NOTES:.
WARRANTY LIMITED WARRANTY for ACDelco Generators from New Buffalo Corporation. Remember to save your receipt and to accurately fill out and ma il your product registration card.
Model AC-G0003 5500 Surge Wa tts / 5000 Running Watts Portable Gen erator 32 NOTES:.
PORTABILITY KIT INSTALLATION The manufacturer recommends when using your ACDelco generator for recreational or utility functions that you properly install t he Portability Kit included with your generator purchase. All ACDelco generator models include a Portability Kit for optional installation.
Model AC-G0003 5500 Surge Wa tts / 5000 Running Watts Portable Gen erator 34 NOTES:.
Model AC-G0003 5500 Surge Wa tts / 5000 Running Watts Portable Gen erator 35 NOTES:.
Model AC-G0003 5500 Surge Wa tts / 5000 Running Watts Portable Gen erator 36.
Model AC-G0003 5500 Surge Wa tts / 5000 Running Watts Portable Gen erator 37 (AC5500070722).
デバイスACDelco AC-G0003の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
ACDelco AC-G0003をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはACDelco AC-G0003の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。ACDelco AC-G0003の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。ACDelco AC-G0003で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
ACDelco AC-G0003を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はACDelco AC-G0003の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、ACDelco AC-G0003に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちACDelco AC-G0003デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。