ATEN TechnologyメーカーCL-1216の使用説明書/サービス説明書
ページ先へ移動 of 82
User Manual CL-1208 CL-1216 cl12816_v2.book Page i Th ursday, March 23, 2006 2:21 PM.
CL-1208 / CL-1216 User Manual ii FCC Information This is an FCC Class A product. In a domestic environment this product may cause radio interference in which cas e the user may be required to tak e adequate measures.
CL-1208 / CL-1216 User Manual iii User Notice All information, docum entation, and specifications contained in this manual are subject to change without prior no tification by the manufacturer.
CL-1208 / CL-1216 User Manual iv Safety Instructions General Read all of these instructions. Save them for future reference. Follow all warn ings and instru ctions marked on the device. Do not place the device on any unstable su rface (cart, stand, table, etc.
CL-1208 / CL-1216 User Manual v Position system cables and power cable s carefully; Be sure that nothing rests on any cables. When connecting or d isconnecting power to hot-pluggab le power supplies, observe the foll owing guidelines: Install the powe r su pp l y before connecting the power cable to the power supply .
CL-1208 / CL-1216 User Manual vi Rack Mounting Before working on the rack, make sure that the stabilizers are secured to the rack, extended to the floor , and that the full weight of the rack rests on the floor . Install front and side stabilizers on a singl e rack or front stabilizers for joined mu ltiple r acks before working on th e rack.
CL-1208 / CL-1216 User Manual vii Package Contents Basic Package The basic CL-1208 / CL-1216 package con sists of: 1CL-1208 / CL-1216 KVM Switch with Standard Rack Mounting Kit 2Custom KVM Cab.
CL-1208 / CL-1216 User Manual viii This Page Intentionally Left Blank cl12816_v2.book Page vii i Thursday, March 23, 2006 2:21 PM.
CL-1208 / CL-1216 User Manual ix Content s FCC Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ii RoHS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CL-1208 / CL-1216 User Manual x Hot Plugging KVM Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Powering Off and Restarting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Port ID Numbering . . .
CL-1208 / CL-1216 User Manual xi Appendix Connection Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 CL-1208 + ACS-1208A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 CL-1216 + ACS-1216A .
CL-1208 / CL-1216 User Manual xii This Page Intentionally Left Blank cl12816_v2.book Page xii Thursday, March 23, 2006 2:21 PM.
CL-1208 / CL-1216 User Manual xiii About this Manual This User Manual is provided to help you get the most from your c/c system. It covers all aspects of installation, configurati on and op erati on. An overview of the information fou nd in th e manual is provided below.
CL-1208 / CL-1216 User Manual xiv Conventions This manual uses the following conven tio ns: Getting Help If you need to contact ATEN techni cal support with a problem , visit or website at www.aten.com . Monospaced Indicates text that you should key in.
1 Chapter 1 Introduction Overview The Master View CL-1208 / CL-1216 KVM Swi tch is a control unit that allows access to multiple computers from a single KVM (keyboard, monitor, and mouse), console.
CL-1208 / CL-1216 User Manual 2 Setup is fast and easy; plugging cables in to their appropriate por ts is all that is entailed. Because the CL-1208 / CL-1216 intercepts keyboard input directly, there is no software to configure; no need to g et involved in complex installation routines ; nor any n eed to be concerned with incompatibility problems.
1. Introduction 3 Features Integrated KVM console with 15"or 17" LCD monitor - in a Slideaway ™ housing Slideaway ™ h ousing is less than 1 U - with top and bottom clearance for smooth operation in a 1U high system rack. Space saving technology - two consoles (one bus) controls up to 8 (CL- 1208) or 16 (CL-1216) computers.
CL-1208 / CL-1216 User Manual 4 Hardware Requirement s Computers The following equipmen t must be installed on each computer: A VGA, SVGA or Multisync card. Note: The integrated LCD monito r's maximum resolution is 1024 x 768 @ 7 5Hz (15") or 1280 x 1024 @ 75 Hz (17").
1. Introduction 5 CL-1208 / CL-1216 Front View 2 3 6 12 9 10 & 11 1 13 13 7 8 4 & 5 2 3 6 12 9 10 & 11 1 13 13 7 8 4 & 5 cl12816_v2.book Page 5 Th ursday, March 23, 2006 2 :21 PM.
CL-1208 / CL-1216 User Manual 6 No. Component Descriptio n 1 Handle Pull to slide the KVM module out; push to slide the module in (see item 13 in this table). 2 LCD Display After sliding the KVM module out, flip up the cover to access the LCD monitor .
1. Introduction 7 CL-1208 / CL-1216 Rear View 1 2 3 4 5 1 2 3 4 5 cl12816_v2.book Page 7 Th ursday, March 23, 2006 2 :21 PM.
CL-1208 / CL-1216 User Manual 8 No. Component Descriptio n 1 Daisy Chain Port When dai sy chaining units, the cable plugs in here. 2 KVM Port Section The cables that link to the computers plu g in here.
9 Chapter 2 Inst allation Before you Begin S t andard Rack Mounting A standard rack mounting kit is pro vid ed with your CL- 1208 / CL-1216. The kit enables the sw itch to be mounted in rack with a dep th of 42.0 - 82.0 cm. Note: It takes two people to mount the switch : one to hold it in place; the other to screw it in.
CL-1208 / CL-1216 User Manual 10 To rack mount the switch, do the following : 1. While one person po sitions the switch in the rack and holds it in p lace, the second person - using the screws provided with the rack mounting kit - loosely screws the front brackets to the rack.
2. Installation 11 Single St age Inst allation In a Single Stage installati on, there are no additional switches daisy chained down from the first unit.
CL-1208 / CL-1216 User Manual 12 1 2 3 4 2 cl12816_v2.book Page 12 T hursday, March 23, 2006 2:21 PM.
2. Installation 13 Daisy Chaining To control even more computers, up to 31 Master View ACS-1208A / ACS- 1216A units can b e daisy chained do wn from the CL-1208 / CL-1216.
CL-1208 / CL-1216 User Manual 14 5. Power up the instal lation according to the following procedure: a) Power on the First S tation (CL-1208 or CL-1216) and wait a few seconds for the unit to ascertain its Station ID. b) Plug in the power adapters for each daisy chained S tation on the installation in turn (Second Station, then Third Station, etc.
2. Installation 15 CL-1216 A CS-1216A A CS-1216A cl12816_v2.book Page 15 T hursday, March 23, 2006 2:21 PM.
CL-1208 / CL-1216 User Manual 16 This Page Intentionally Left Blank cl12816_v2.book Page 16 T hursday, March 23, 2006 2:21 PM.
17 Chapter 3 Basic Operation Opening the Console The CL-1208 / CL-1216's console is lo cated under the top cover. To access the console, slide the co nsole module out and raise the cover. Note: As a safety precaution, to keep th e console from accidentally s liding out, the console is locked into the In po si tio n.
CL-1208 / CL-1216 User Manual 18 Closing the Console To slide the console module back in , close the cover and do the following: 1. Pull the safety catches on the unit's side rails toward you and push the module in unti l it stops. 2. Release the catches; pull the module sli ghtly toward you; then push it all the way in.
3. Basic Operation 19 Operating Precautions Right! Rest your hands and arms lightly on the keyboard module as you work. Wro ng ! DO NOT lean your body weight on the keyboard module. DO NOT place heavy objects on the keyboard module. The maximum load bearing capacity of the keybo ard m odu le is 30kg.
CL-1208 / CL-1216 User Manual 20 LCD OSD Configuration The LCD Buttons The LCD OSD allows you to set up and configure the LCD display. Four buttons are used to perform the co nfigura tion, as describe.
3. Basic Operation 21 The Adjustment Settings An explanation of the LCD OSD adjustment settings is given in the table below: Setting Explanation Brightness Adjusts the background bl ack level of the screen image. Contrast Adjusts the foreground white level of the screen image.
CL-1208 / CL-1216 User Manual 22 Port Selection The CL-1208 / CL-1216 prov ides three port selection methods to access the computers on the installation: Manual ; OSD (On Screen Display) men us, and Hotkey. OSD Operation is discussed in the next chapter; Hotkey Port Select ion is discussed de tail in Chapter 5.
3. Basic Operation 23 Hot Plugging The CL-1208 / CL-1216 supports hot plugging - components can be removed and added back into the install ation by unplugging t heir cables from the ports without the need to shut the unit down.
CL-1208 / CL-1216 User Manual 24 Powering Off and Rest arting If it becomes necessary to Power Off one of the ACS- 1208A / ACS-1216A units, unplug the power adapter cable from the rear panel. Before starting it back up you must do the following: 1. Shut down all the com put ers that are attached to it.
3. Basic Operation 25 Port ID Numbering Each KVM port on a Master View installation is assigned a unique Port ID. The Port ID is made up of two parts: a Station Number , and a Port Number : The S tation Number - is a two digit number whi ch reflects the switch's position in the daisy chain sequence.
CL-1208 / CL-1216 User Manual 26 This Page Intentionally Left Blank cl12816_v2.book Page 26 T hursday, March 23, 2006 2:21 PM.
27 Chapter 4 OSD Operation OSD Overview The On Screen Display (OSD) is a menu d riven method to handle computer control and switchi ng operations. All pr ocedures start from the OSD Main Screen. To pop up the Main Screen, tap the OSD key (see p. 63), or tap the [Scroll Lock] key twice.
CL-1208 / CL-1216 User Manual 28 When you invoke the OSD, a screen similar to the one below appears: Note: 1. The diagram depicts the Administra tor's Main Screen. The User Main Screen does not show the F4 and F6 functions, since these are reserved for the Administrator and can't be accessed by ordinary Users.
4. OSD Operation 29 OSD Navigation T o dismiss the menu, and d eactivate the OSD, Click the X at the upper right corner of the OSD W indow; or press [Esc] . T o Logout, Click F8 or the Z Z Z symbol at the top of the Main Screen, or press [F8] .
CL-1208 / CL-1216 User Manual 30 OSD Functions OSD functions are used to configure an d control the OSD. For example, you can: rapidly switch to any port; scan selected ports only; limit the list you wish to view; designate a port as a Quick Vi ew Port; create or edit a port name; or make OSD setting adjustments.
4. OSD Operation 31 F2 LIST This function le ts you broaden or narr ow the scope of which ports th e OSD displays (lists) on the Main Screen. Many of the OSD fun ctions only operate on the computers currently selected for Listing on the Main Screen with this function.
CL-1208 / CL-1216 User Manual 32 F3 SET This function allows the Administrator and each User to set up their own, individual, working environm ent. A sep arate profile for each is stored by the OSD and is activated according to th e Username provided during Login.
4. OSD Operation 33 (Continued from previous page.) Setting Function PORT ID DISPLA Y MODE Selects how the Port ID is displayed: the Port Number alone ( PORT NUMBER ); the Port Name alone ( PORT NAME ); or the Port Number plus the Port Name ( PORT NUMBER + PORT NAME ).
CL-1208 / CL-1216 User Manual 34 F4 ADM F4 is an Administrator only fun ction. It allows the Administrator to con figure and control the overall oper ation of the OSD. To change a setting Double Click it; or use the Up and Down Arrow Keys to m ove th e highlight bar to it then press [Enter] .
4. OSD Operation 35 (Continued from previous page.) (Table continues on next page.) Setting Function EDIT PORT NAMES T o help remember which computer is attached to a particular port, every port can be given a name. This function allows the Administrator to create, modify , or delete por t names.
CL-1208 / CL-1216 User Manual 36 (Continued from previous page.) (Table continues on next page.) Setting Function SET QUICK VIEW PORTS This function lets the Administrator select which Ports to include as Quick View ports .
4. OSD Operation 37 (Continued from previous page.) Setting Function RESET ST A TION IDS If you change the position of one of the St ations in the daisy chain, the OSD settings will no longer correspond to the new situation.
CL-1208 / CL-1216 User Manual 38 F5 SKP This function enables you to easily skip backward or forw ard - switching the KVM focus from the currently active comp uter port to the previou s or next available one.
4. OSD Operation 39 F6 BRC F6 is an Administrator only function. When this function is in effect, commands sent from the console are br oadcast to all available computers on the installation.
CL-1208 / CL-1216 User Manual 40 F7 SCAN This function automatically switches am ong the available computers at regular intervals so that you can monito r thei r activity without having to tak e the trouble of switching ma nually.
4. OSD Operation 41 F8 LOUT Clicking the F8 field or, o r pressing [F8] logs you out of the OSD, and blanks the Console screen. This is different from simply deactiv ating the OSD when you are at the Main Screen by pressing [Esc].
CL-1208 / CL-1216 User Manual 42 This Page Intentionally Left Blank cl12816_v2.book Page 42 T hursday, March 23, 2006 2:21 PM.
43 Chapter 5 Hotkey Operation Hotkey Port Access Hotkey Port Access allows you to provide the KVM focus to any computer on your installation directl y from the keyboard.
CL-1208 / CL-1216 User Manual 44 Selecting the Active Port Each KVM port is assigned a unique Port ID (see Port ID Numbering , p. 25). You can directly access an y computer on the inst allation with a Hotkey combination that specifies the Port ID of the KVM Port that the computer is connected to.
5. Hotkey Operation 45 Invoking Auto Scan: To start Auto Scanning, key in the fol low ing Hotkey combination: 1. Invoke HKM (see p. 43). 2. Press [A] .
CL-1208 / CL-1216 User Manual 46 Skip Mode This feature allows you to switch between comput ers in order to monito r them manually. You can dwel l on a particular port for as long or as little as you like - as opposed to Auto Scanning, whic h automatically switches after a fixed interval.
5. Hotkey Operation 47 Hotkey Beeper Control The Beeper can be Hotkey toggled On and Off (see Activate Beeper, p. 35). To toggle the Beeper, key in the foll o wing Hotkey comb in at ion: 1. Invoke HKM (see p. 43). 2. Press [B] After you press B , the Beeper toggles On or Off.
CL-1208 / CL-1216 User Manual 48 Hotkey Summary T able [Num Lock] + [-] [Port ID] [Enter] Switches the KVM focus to the computer that corresponds to that Port ID [A] Invokes Auto Scan Mode. When Auto Scan Mode is in effect, [P] or Left Click pauses Auto Scanning.
49 Chapter 6 The Firmware Upgrade Utility The Windows-based Firmware Upgrade Uti lit y (FWUpg rade.exe) provides a smooth, automated process for u pgrading the KVM swit ch's firmware. The Utility comes as part of a Firmware Upgrade Package th at is specific for each device.
CL-1208 / CL-1216 User Manual 50 Prep aration To prepare for the firmware upgrade, do the following: 1. From a computer that is not part of your KVM installation go to our Inter- net support site and choose the model name that rel ates to you r devi ce to get a list of available Firmware Upgrade Packages.
6. The Firmware Upgrade Utility 51 S t arting the Upgrade To upgrade your firmware: 1. Run the down loaded Firmware Upgrade Package file - either by double clicking the file icon, o r by openin g a command line and entering the full path to it.
CL-1208 / CL-1216 User Manual 52 3. Click Next to continu e . The Fi rm ware Upgrade Utility main screen appears. The devices capable of being upgra ded are listed in the Device List panel: 4. As you select devices, a detailed des cription of each appears in the Device Description panel.
6. The Firmware Upgrade Utility 53 5. After you have made your device selection(s), Click Next to perform the upgrade. If you enabled Check Firmwar e V ersion , the Utility comp ares the device's firmware level with that of the upgrade files.
CL-1208 / CL-1216 User Manual 54 Upgrade Succeeded After the upgrade has completed, a screen appears to info rm you that the procedure was successful: Click Finish to close the Firmwa re Upg rade Ut ili ty. Upgrade Failed If the Upgrade Succeeded sc reen doesn't appear, it means that the upgrade failed to complete successfully.
6. The Firmware Upgrade Utility 55 Firmware Upgrade Recovery There are basically three conditions that call for firmware upg rade reco very: When you invoke Firmware Upgrade Mode (see Preparation , p. 50), but decide not to proceed with the upgrade.
CL-1208 / CL-1216 User Manual 56 This Page Intentionally Left Blank cl12816_v2.book Page 56 T hursday, March 23, 2006 2:21 PM.
57 Appendix Connection T ables The following tables indicate the relationshi p between the number of Master View units and the number of computers that they control on a daisy chained installation: CL.
CL-1208 / CL-1216 User Manual 58 OSD Factory Default Settings The factory default se ttings are as follows: Setting Default OSD Hotkey [Scroll Lock] [Scroll Lock] Port ID Display Position Upper Left C.
7. Appendix 59 Clear Login Information If you are unable to perform an Admini strator login (because the Username and Password information has become corrupted, or you have forgotte n it, for example), you can clear the login info rmation with the following procedure: 1.
CL-1208 / CL-1216 User Manual 60 Optional Rack Mounting For convenience and flexibility, three option a l rack m ount ing kits are available: A long bracket standard rack mounting kit for 68.0 - 110.0 cm racks; A short bracket Easy-Installation rack moun t kit for 52.
7. Appendix 61 2. Attach the left and right easy-installation mounting rails to the insid e of the rack. The flange that supports the switch will be to the inside.
CL-1208 / CL-1216 User Manual 62 3. Slide the switch onto the support fla nges. Use the screws supplied with this package to loosely attach the front of the switch to the front of the rack (only tighten the screws part way).
7. Appendix 63 5. Slide the switch open and closed a coupl e of times to be sure t hat it is properly aligned and operating smoothly . (See p.17 for opening and closing procedures.
CL-1208 / CL-1216 User Manual 64 Specifications (Table continues on next page.) Function CL-1208 C L-1216 Computer Connections Direct 8 16 Max 256 (via Daisy Chain) 512 (via Daisy Chain) Port Selectio.
7. Appendix 65 (Continued from previous page.) T roubleshooting Function CL-1208 CL-1216 Environment Operating Temp. 0 - 40 o C Storage Temp. -20 - 60 o C Humidity 0 - 80% RH Physical Properties Ho using Metal Weight 15” LCD: 14.1 kg 15” LCD: 14.3 kg 17” LCD: 14.
CL-1208 / CL-1216 User Manual 66 Limited W arranty IN NO EVENT SHAL L THE DIRECT V ENDOR'S LIABILITY EXCEED THE PRICE PAID FOR THE PRODUCT FROM THE DIRECT, INDI RECT, SPECIAL, IN CIDENTAL OR CONSEQUENTIAL DAM AGES RESULTING FROM T HE USE OF THE PRODU CT, DISK OR ITS DOCUMENTATION.
67 Index A Activate Beeper, 35 ADM, 34 Administrator functions, 34 Auto Scanning, 40, 44 Invoking Auto Scan, 45 Pausing Auto Scan, 45 Scan Durati on, 33 Setting the Scan Interval, 44 Stopping, 45 B Be.
CL-1208 / CL-1216 User Manual 68 L LCD OSD configuration, 20 LIST, 31 Logout, 41 Logout Timeout, 34 LOUT, 41 O OSD Factory Default Settings, 5 8 Functions, 3 0 Hotkey, 27, 32 Logout, 41 Main Screen, 2.
デバイスATEN Technology CL-1216の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
ATEN Technology CL-1216をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはATEN Technology CL-1216の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。ATEN Technology CL-1216の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。ATEN Technology CL-1216で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
ATEN Technology CL-1216を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はATEN Technology CL-1216の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、ATEN Technology CL-1216に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちATEN Technology CL-1216デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。