Pitco FrialatorメーカーSSHLV14の使用説明書/サービス説明書
ページ先へ移動 of 38
L20-407 rev. 1 (3/14) IMPORTANT FOR FUTURE REFERENCE Please complete this information and retain this manual for the life of the equipment: Model #: ___________________________ Serial #: _____________.
TO THE PURCHASER, OW NER AND STORE MANAGER Please review these warnings prio r to posting them in a prom inent location for reference. ii L20-407 rev.1 (3/14) TO THE PURCHASER Post in a prominent location the in structions to be followed in the event that an o perator smell s gas.
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL L20-407 rev. 1 (3/14) 3 1. THEORY OF OPERATION .............................................................................................................................. 5 2.
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL 4 L20-407 rev.1 (3/14) 5.19. C ONTROL OR T IMER : (L EFT SIDE OF D UAL OR S INGLE V AT ) ...................................................................
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL L20-407 rev. 1 (3/14) 5 1. THEORY OF OPERATION The Pitco Low (or reduced) Oil Volume fryer works very similarly to the Pitco standard SG/SSH fryer. The Low Oil Volume Fryer has a reduced cold zone to significantly reduce oil usage and extend oil life.
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL 6 L20-407 rev.1 (3/14) 2. INSTALLATION 2.1. CHECKING AN D UNPACKING YOUR NEW APPLIANCE Your new Pitco appliance has been carefully pack ed into one crate. Every effort has been made to ensure that it is delivered to you in perfect condition.
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL L20-407 rev. 1 (3/14) 7 2.3. LEVELING THE FRYER – LEGS/CASTERS CAUTION To prevent equipment damage and/or personal injury , do not tilt the appliance onto any two of its casters or legs, or pull the appliance by the splash back .
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL 8 L20-407 rev.1 (3/14) 2.4. GAS CONNECTION Your gas appliance will give you peak p erformance when the gas supply line is of sufficient size to provide the correct gas pressure. The gas line must be install ed to meet the local building codes or National Fuel Gas Code ANSI Z223.
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL L20-407 rev. 1 (3/14) 9 2.8. ELECTRICAL CONNECTIONS It is advised that this power supply be plugge d into a wall receptacle that is controlled by the ventilation control. This will prevent the applia nce from being operated without the ventilator on.
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL 10 L20-407 rev.1 (3/14) For Australia, the fryer must be installed in accor dance with AS/NZS 5601, local authority and any other relevant statutory regulations.
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL L20-407 rev. 1 (3/14) 11 ON OFF PUSH BLUE HANLDE IN 2.11. INITIAL ADJUSTMENTS After your appliance has been properly installe d as described in the installation section of this manual, it will need to be adjusted to ensure that it will perform as designed.
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL 12 L20-407 rev.1 (3/14) OFF ON A) Burner Pressure Tap B) Pilot Adjustment Screw Cap C) ON/OFF Knob D) Burner Pressure Adjustment Screw Cap E) Inlet Pressure Tap 2.11.3. PILOT FLAME ADJ USTMENT Perform this procedure with the pilot lit.
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL L20-407 rev. 1 (3/14) 13 To adjust the pressure, remove the regulator adjust ment screw cap and, with a flat head screwdriver, adjust the regulator screw until the proper bu rner pressure is reached. Turning the screw clockwise will increa se the burner pressure.
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL 14 L20-407 rev.1 (3/14) 3. OPERATION An operator’s manual for your applian ce’s specific control type should be includ ed with this manual. Refer to that manual prior to operating this appli ance.
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL L20-407 rev. 1 (3/14) 15 3.2. BASIC OPERATIONAL FEATURES 1 . Basket Hanger - Holds fry baskets while draining or bet ween loads. Lifts off for easy cleaning. 2. Fry pot oil top off supply jug- Supplied by others, provides on b oard storage for fresh cooking oil.
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL 16 L20-407 rev.1 (3/14) 3.3. FILLING THE FRY POT Only use shortening that is liquid at room temperature in this appliance. 3.4. FILLING THE TANK WITH LIQUID SHORTENING To fill the tank with liquid shorteni ng, refer to the following procedure.
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL L20-407 rev. 1 (3/14) 17 WARNING Oil level should NOT be allowed to fall below the minimum indicated level line at any time. Dry firing of the elements may cause a fire, and can shorten element service life.
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL 18 L20-407 rev.1 (3/14) Typical French Fry Cook Times Fry Thickness 350F 360F 370F (177C) (182C) (188C) Thin 2:45 2:30 2:15 medium 3:45 3:30 3:15 Thick 4:15 4:00 3:45 This table is for reference only.
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL L20-407 rev. 1 (3/14) 19 4 5. COMPUTER CONT ROLLER OPERATION 3 1 L2 5 4 68 7 0 9 R 5.1. TO TURN THE APPLIANCE ON: If power is applied to the appliance, the displays will show [OFF]. Press the [I/O] key.
INSTALLATION & OPERATIONAL SGLV MANUAL 20 L20-407 rev.1 (3/14) 4 12 2 00 1 5.6. TO VIEW CURRENT SETTINGS FOR COO K, SHAKE, AND HOLD TIMES: To view the current settings for any produc t key, press the clock key, followed by the desired product key.
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL L20-407 rev. 1 (3/14) 21 Level 1 & 2 Password 6 8 64 5.8. TO ENTER PROGRAMMING L EVEL 1 (FOR THE STORE MANAGER): Note: The factory default setting for this control do es not require an operator password to be entere d.
INSTALLATION & OPERATIONAL SGLV MANUAL 22 L20-407 rev.1 (3/14) 0 1 2 5.10.4. HOLD PRE-ALARM Hold Pre-Alarm is a timer setting that is used to warn operators that the Hold Time is about to expire. To use Hold Pre-Alarm, time value must be a non-zero value, and must be set to a value less than Hold Time.
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL L20-407 rev. 1 (3/14) 23 3 4 5 6 7 5.15. BEEPER VOLUME AND TONE: Volume and Tone of the beeper alarm may be changed in this se ction. Volume ranges are 1,2 and 3, where 3 is the loudest setting. With display showing [PROGRAM ], press the product k ey [0].
INSTALLATION & OPERATIONAL SGLV MANUAL 24 L20-407 rev.1 (3/14) 8 5.20. CONTROL OR TIMER: (RI GHT SIDE OF DUAL VAT) Note: This key has no function of single vat controls. With display showing [PROGRAM ], press the product k ey [0]. Display shows [SELECT] [OPTIONS].
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL L20-407 rev. 1 (3/14) 25 LOW BOTTLE LIGHT 6. BASKET LIFT OPERATIO N If the appliance is equipped with basket lifts, plac e the basket onto the basket lift prior to starting the timer(s). The basket(s) will be lowered into the cook tank when a product key is pressed.
INSTALLATION & OPERATIONAL SGLV MANUAL 26 L20-407 rev.1 (3/14) 9. QUICK STRAIN FILTERING “Filter Soon” light flashing ( WARNING: Turn OFF Fryer, before filtering. Wear oil proof, insulated gloves while filtering.) Refer to the following procedure for quick strain filtering.
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL L20-407 rev. 1 (3/14) 27 11. APPLIANCE SHUTDOWN There are two shutdown modes of applianc e operati on: STANBY and COMPLETE. The standby mode removes the ability of the appliances main burners to operate.
INSTALLATION & OPERATIONAL SGLV MANUAL 28 L20-407 rev.1 (3/14) 1. Filter Pan 2. Filter Pickup Assembly 3. Filter Strainer Cap 4. Filter Paper 5. Filter Screen 12.1.2. REPLACING THE FILTER MEDIA (IF EQUIPPED) Refer to the following procedure to replace the filter media if the appliance i s equipped with a filter drawer .
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL L20-407 rev. 1 (3/14) 29 WARNING Serious injury could re sult from direct contact with hot surfaces and/or oil . Always wear apron, heat resistant glo ves for skin protection an d goggles for eye protecti on WARNING DO NOT leave the appliance unattend ed during cleaning.
INSTALLATION & OPERATIONAL SGLV MANUAL 30 L20-407 rev.1 (3/14) 4. Wipe the filter pan with clean damp cloth and a food g rade detergent. If necessary place pan in pot sink to rinse all the detergent from the surfaces and dry all surfaces before re- assembly.
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL L20-407 rev. 1 (3/14) 31 5. Close the drain valve and fill the tank with potable wat er to the level lines. 6. Place the appliance into boil mode: Turn the appliance ON. The controller will reco gni ze that there is water in the tank and automatically enter boil mode.
INSTALLATION & OPERATIONAL SGLV MANUAL 32 L20-407 rev.1 (3/14) WARNING The power supply must be disconn ected before cleaning and servicing this appliance! 12.4. ANNUAL/PERIODIC PRE VENTATI VE MAINTENANCE AND INSPECTION This section should ONLY be perfo rmed by a qualified service technician as part of a regula r kitchen maintenance program.
INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL L20-407 rev. 1 (3/14) 33 12.4.5. GAS COMBUSTION SYSTEM Check fo r gas leaks. Check and cl ean vent tube on gas valve pressure regulator. Check burners, clea n debris and grease from pilot and pilot orifice tips.
INSTALLATION & OPERATIONAL SGLV MANUAL 34 L20-407 rev.1 (3/14) 13. TROUBLESHOOTING 13.1. POWER FAILURE If electric power is remo ved for any reason, the appliance will shut down. Wait five minutes after the power is restored before attempting to restart the ap pliance.
INSTALLATION & OPERATIONAL SGLV MANUAL L20-407 rev. 1 (3/14) 35 13.4. SELF CLEANING BURNER SYSTEM (NOT ON ALL MODELS) If your appliance is equipped with the self cleani ng burner system, the applian ce should behave as outlined in the table below.
INSTALLATION & OPERATIONAL SGLV MANUAL 36 L20-407 rev.1 (3/14) 13.6. TROUBLESHOOTING CHAR TS 13.6.1. FRYER TROUBLES HOOTING CHART 13.6.2. FILTER TROUBLESHOOTING CHART (IF EQUIPPED) Problem Probable Causes Corrective Actions Controller does not activate.
INSTALLATION & OPERATIONAL SGLV MANUAL L20-407 rev. 1 (3/14) 37 13.6.3. COMPUTER & DIGITAL CO NTROLLER DISPLAYS (IF EQUIPPED) If your appliance is equipped with a computer o r digital controller it may display the following messages on its display.
L20-407 rev. 0 (01/13) Annual service to this appliance by an authori zed pers on is recommended. Do not modify this appliance: servicing must only be carried out by an authorized pe rson.
デバイスPitco Frialator SSHLV14の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Pitco Frialator SSHLV14をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPitco Frialator SSHLV14の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Pitco Frialator SSHLV14の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Pitco Frialator SSHLV14で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Pitco Frialator SSHLV14を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPitco Frialator SSHLV14の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Pitco Frialator SSHLV14に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPitco Frialator SSHLV14デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。