V ORTEX ® A PPLICATION S AND P RESETS G UIDE Polycom, Inc., Copyright 200 1 Technical Support: ( 800) 932-2774 1 Introduction ....................................................................................................2 Building Your Syst em with Multiple Vortexes® .
I NTRODUCTION Vortex ® Applications and Presets Guide 2 Technical Support: (800) 93 2-2774 I NTRODUCTION This manual describes useful application information and the f actory presets of the Vo r t e x ® .
B UILDING Y OUR S YSTEM WITH M ULTIPLE V OR - © Polycom, Inc. 3 Vortex ® Applicat ions and Pr es ets Guide B UILDING Y OUR S YSTEM WITH M ULTIPLE V ORTEXES ® The following is a checklist for building a system with mult iple V ortexes: 1. Assign Inputs.
B UILDING Y OUR S YSTEM WITH M ULTIPLE V OR - Vortex ® Applications and Presets Guide 4 Technical Support: (800) 93 2-2774 be mixed with the other inputs to create Outputs 1-8, A-D, Ref 1, Ref 2, and W , X, Y , and Z bus outputs.
B UILDING Y OUR S YSTEM WITH M ULTIPLE V OR - © Polycom, Inc. 5 Vortex ® Applicat ions and Pr es ets Guide an echo canceller reference on the EF Bus.
B UILDING Y OUR S YSTEM WITH M ULTIPLE V OR - Vortex ® Applications and Presets Guide 6 Technical Support: (800) 93 2-2774 Operating as One Automixer with Multiple V ortexes T o set the V ortex to operate as one au tomixer across several V ortexes, set the B US M IXER parameter on all V ortexes to the same automixer gr oup.
B UILDING Y OUR S YSTEM WITH M ULTIPLE V OR - © Polycom, Inc. 7 Vortex ® Applicat ions and Pr es ets Guide C ONNECTING M ULTIPLE V ORTEXES Up to 8 V ortexes can be linked together at one time. Each unit in the chain must have a unique Device ID. Use the EF Bus to link multiple V o rtexes together .
B UILDING Y OUR S YSTEM WITH M ULTIPLE V OR - Vortex ® Applications and Presets Guide 8 Technical Support: (800) 93 2-2774 The V ortex does not have to be terminated if you are using a sing le unit not connected together with another V ortex. Figure 3.
B UILDING Y OUR S YSTEM WITH M ULTIPLE V OR - © Polycom, Inc. 9 Vortex ® Applicat ions and Pr es ets Guide Connecting the V ortex with Other EchoFree Devices If you are linking multiple V ort exes, you must use the EF bus to link the V ortexes to each other .
P RESETS Vortex ® Applications and Presets Guide 10 Technical Support: (800) 93 2-2 774 P RESETS Vortex ® In 1 In 2 In 3 In 4 In 5 In 6 In 7 In 8 Out 1 Out 2 Out 3 Out 4 Out 5 Out 6 Out 7 Out 8 In A In B Out A Out B In D Out C Out D In C Vortex Factory Preset 0: Default Video CODEC Line In Line Out EF200 From AEC From Rem.
P RESETS © Polycom, Inc. 11 Vortex ® Application s and Preset s Guide Vortex ® In 1 In 2 In 3 In 4 In 5 In 6 In 7 In 8 Out 1 Out 2 Out 3 Out 4 Out 5 Out 6 Out 7 Out 8 In A In B Out A Out B In D Out C Out D In C Video CODEC Line In Line Out EF200 From AEC From Rem.
P RESETS Vortex ® Applications and Presets Guide 12 Technical Support: (800) 93 2-2 774 Vortex ® In 1 In 2 In 3 In 4 In 5 In 6 In 7 In 8 Out 1 Out 2 Out 3 Out 4 Out 5 Out 6 Out 7 Out 8 In A In B Out A Out B In D Out C Out D In C Vortex Factory Preset 2: Split, Mono Video CODEC Line In Line Out EF200 From AEC From Rem.
P RESETS © Polycom, Inc. 13 Vortex ® Application s and Preset s Guide Vortex Factory Preset 4: 8 mics/Zone Vortex ® In 1 In 2 In 3 In 4 In 5 In 6 In 7 In 8 Out 1 Out 2 Out 3 Out 4 Out 5 Out 6 Out 7 Out 8 In A In B Out A Out B In D Out C Out D In C Video CODEC Line In Line Out EF200 From AEC From Rem.
P RESETS Vortex ® Applications and Presets Guide 14 Technical Support: (800) 93 2-2 774 The Submatrix assumes that V ortex 01 is the next closest zone, V ortex 02 is th e next one, etc., and V ortex 07 is the farthest zone (reinforced at the highest level).
P RESETS © Polycom, Inc. 15 Vortex ® Application s and Preset s Guide Vortex ® In 1 In 2 In 3 In 4 In 5 In 6 In 7 In 8 Out 1 Out 2 Out 3 Out 4 Out 5 Out 6 Out 7 Out 8 In A In B Out A Out B In D Out.
P RESETS Vortex ® Applications and Presets Guide 16 Technical Support: (800) 93 2-2 774 The Submatrix assumes that V ortex 01 is the next closest zone, V ortex 02 is th e next one, etc., and V ortex 07 is the farthest zone (reinforced at the highest level).
P RESETS © Polycom, Inc. 17 Vortex ® Application s and Preset s Guide Vortex ® In 1 In 2 In 3 In 4 In 5 In 6 In 7 In 8 Out 1 Out 2 Out 3 Out 4 Out 5 Out 6 Out 7 Out 8 In A In B Out A Out B In D Out C Out D In C Vortex Factory Preset 6: 4 mics/Zone Video CODEC Line In Line Out EF200 From AEC From Rem.
P RESETS Vortex ® Applications and Presets Guide 18 Technical Support: (800) 93 2-2 774 Presets 3, 7-12 Reserved. Preset 13 Passthrough Mic. Passthrough mode (Inpu ts 1-8, A-D are direct ou t) with Inputs 1-8 set to Mic level. Everything else is disabled.
デバイスPolycom EF2280の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Polycom EF2280をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPolycom EF2280の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Polycom EF2280の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Polycom EF2280で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Polycom EF2280を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPolycom EF2280の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Polycom EF2280に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPolycom EF2280デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。