PolycomメーカーSpectraLink 1725-36143-001の使用説明書/サービス説明書
ページ先へ移動 of 21
July 2008 Edition 1725-36143-001 Version K Siemens Hicom/HiPath optiset LinkPlus Interface Guide for SpectraLink e340/h340/i640 Wireless Telephones.
LinkPlus Interface Guide: Siemens Hicom/HiPath optiset for SpectraLin k e340/h340/i640 Wireless Telephones 2 PN: 1725-36143-001_K.doc Trademark Information Polycom® and t he logo design s SpectraLink® LinkPlus Link NetLink SVP Are trademarks and registe red trademarks of Polycom, Inc.
PN: 1725-36143-001_K.doc 3 About This Guide Polycom is the market leader in multi-cellular wireless telephone systems for the workplace. We manufacture a range of products to suit any size installation. SpectraLink 8000 Telephony Gatewa y uses our LinkPlus digital integration te chnology to integrate with various digital switch platforms.
LinkPlus Interface Guide: Siemens Hicom/HiPath optiset for SpectraLin k e340/h340/i640 Wireless Telephones PN: 1725-36143-001_K.doc 4 Customer Support Polycom wants you to have a successful installation. If you have questions please contact the Cu stomer Support Hotline at (800) 775-5330.
PN: 1725-36143-001_K.doc 5 Plan the Interface The system administrator programs the telephone system for use with the SpectraLink 8000 System using the normal administration terminal or procedures. Programming can be done after the hands ets are registered.
LinkPlus Interface Guide: Siemens Hicom/HiPath optiset for SpectraLin k e340/h340/i640 Wireless Telephones PN: 1725-36143-001_K.doc 6 handsets, which line or lines should ring at which handset; and which line will be selected when the user goes off-hook.
Plan the Interface PN: 1725-36143-001_K.doc 7 The SpectraLink Wireless Telephone (not to scale) 1 SpectraLink e340 Wireless Telephone SpectraLink i640 Wireless Telephone The handset has a pixel-based alpha numeric display (up to 4-line x 16-character), plus line and status indicators.
LinkPlus Interface Guide: Siemens Hicom/HiPath optiset for SpectraLin k e340/h340/i640 Wireless Telephones PN: 1725-36143-001_K.doc 8 Certain characters may be used by the Hicom CS that are not implemented in the handset. Flashi ng characters are not implemented on the handset, nor is rolling or scrolling of text.
Plan the Interface PN: 1725-36143-001_K.doc 9 Handset Modes Standby(on-hook) In the standby mode the hands et is waiting for an incoming call or for the user to place an outgoing call. The extension number is shown on the display and there is no dial tone.
LinkPlus Interface Guide: Siemens Hicom/HiPath optiset for SpectraLin k e340/h340/i640 Wireless Telephones PN: 1725-36143-001_K.doc 10 LED emulation When Lines are programmed as shown on the k ey-map diagrams, the numeral icons on the handset display will be mapped to the LEDs associated with the corresponding Feature Keys.
Plan the Interface PN: 1725-36143-001_K.doc 11 have their corresponding menu items display on the handset function menu. See the key-map diagram for the function keys that are available for feature programming.
LinkPlus Interface Guide: Siemens Hicom/HiPath optiset for SpectraLin k e340/h340/i640 Wireless Telephones PN: 1725-36143-001_K.doc 12 OptiGuide menu The OptiGuide menu provides access to features appropriate to the current context of the handset.
Plan the Interface PN: 1725-36143-001_K.doc 13 Hicom 300/HiPath 4000 Phone Test access code The Hicom 300/HiPath 4000 Phone Test (access code*940) will not work on the SpectraLink e340/h340/i640 Wireless Telephones. Button programming For the Hicom 150/HiPath 3000, phone button programming (access code *91) will not work.
.
PN: 1725-36143-001_K.doc 15 Interface Implementation This section describes the recommended programming to use the SpectraLink 8000 Telephony Gateway with the Siemens Hicom 150/ HiPath 3000 E and 300 E/H Communications Server (CS). The procedures assume: • The Siemens Hicom CS system is installed and initialized.
LinkPlus Interface Guide: Siemens Hicom/HiPath optiset for SpectraLin k e340/h340/i640 Wireless Telephones PN: 1725-36143-001_K.doc 16 Siemens optiset Diagrams The diagrams on these pages illustrate additional features that may be programmed to softkeys and shortcut keys.
Interface Implementation PN: 1725-36143-001_K.doc 1 7 The FCN and LINE labels represent the key sequ ence on the handset mapped to the corresponding key on the optiset E.
LinkPlus Interface Guide: Siemens Hicom/HiPath optiset for SpectraLin k e340/h340/i640 Wireless Telephones PN: 1725-36143-001_K.doc 18 78 9 0 * # PQRS TUV WXYZ Siemens optiset E Basic - Hicom 150/Hi Path 3000 Key-mapping The FCN and LINE labels represent the key sequ ence on the handset mapped to the corresponding key on the optiset E.
Interface Implementation PN: 1725-36143-001_K.doc 19 The handset function menu has these default setti ngs: FCN + 0 = Select FCN + 2 = Voicemail (corresponds to the Mailbox feature key abov e) FCN + *.
.
PN: 1725-36143-001_K.doc 21 Extension Assignments Worksheet Shelf: _______ Interface Module: _______ Handset # Ext. # Name Interface Module Circuit # Comment Handset Serial # Handset 1 1 Handset 2 2 H.
デバイスPolycom SpectraLink 1725-36143-001の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Polycom SpectraLink 1725-36143-001をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPolycom SpectraLink 1725-36143-001の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Polycom SpectraLink 1725-36143-001の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Polycom SpectraLink 1725-36143-001で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Polycom SpectraLink 1725-36143-001を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPolycom SpectraLink 1725-36143-001の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Polycom SpectraLink 1725-36143-001に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPolycom SpectraLink 1725-36143-001デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。