Powercomメーカー425Aの使用説明書/サービス説明書
ページ先へ移動 of 17
U P S Uninterruptible Power System Line Interactive UPS 325A/425A/525A/625A Line Interactive Network UPS 425AP/525AP/625AP USER ‘ S MANUAL.
Important safety instructions __________________________________________________________ _____ Thank you for selecting this uninterruptible power system (UPS).
Table of contents __________________________________________________________ ____ 1. Introduction ……… ……… ………… ……… … ..1 2. Safety ………… …………… ………… ………… 2 3. Presentation Front Panel. … ……………… ……………… 3 Rear Panel.
1. INTRODUCTION __________________________________________________________ _____ The product is line interactive UPS with the newest technology and powerful function. The LINE INTERACTIVE ups is with AVR function allows input voltage range from 75% to 125%, including on line voltage boost-up & buck down.
2. Safety __________________________________________________________ _____ CAUTION ! ● To reduce the risk of electric shock, disconnect the UPS from the mains supply before installing a computer interface signal cable. Reconnect the power cord only after signaling interconnections have been made.
3. Presentation __________________________________________________________ ____ FRONT PANEL 3.1 "REPLACE BATTERY" indicator (RED LED) The LED illuminates when the UPS's battery is no longer useful and must be replaced.
__________________________________________________________ __ REAR PANEL 3.5 COMPUTER INTERFACE (425AP/525AP/625AP models only) Provide both RS-232 and relay signal to support NOVELL, UNIX, DOS, WINDOWS and other operating systems. 3.6 OUTPUT POWER RECEPTACLES 3.
4. Installation __________________________________________________________ ____ 4.0 Inspection Inspect the UPS upon receipt. The packaging is recyclable; save it for reuse or dispose of it properly. 4.1 Placement Install the UPS in a protected area with adequate air flow and free of excessive dust.
4.5 Connect the loads Plug the loads into the output connectors on the rear of the UPS. To use the UPS as a master on/off switch, make sure all of the loads are switched on. Caution: Never connect a laser printer or plotter to the UPS with other computer equipment.
5. Operation __________________________________________________________ ____ 5.1 Switch on With the UPS plugged in, press and hold the on/off/test/silence button more than 1 second until "LINE NORMAL" LED lit to switch the ups on. The UPS will perform self-testing each time when it is switched on.
6. Alarm __________________________________________________________ _____ 6.1 "BACK UP" (slow alarm) When in BACK UP mode, the YELLOW LED illuminates and the UPS sounds an audible alarm. The alarm stops when the UPS returns to LINE NORMAL operation.
7. Software options __________________________________________________________ ____ 7.1 UPSMON Software The UPSMON software is applied standard RS-232 interface to perform monitoring functions, and then provides an orderly shutdown of a computer in the event of power failure.
8. Computer Interface Port __________________________________________________________ ____ The computer interface port has the following characteristics:.
9. Battery Replacement __________________________________________________________ ____ Your battery should run any where from 3-5 years before eve needing to be replaced. Please follow the instructions below for easy battery replacement. 1) Unplug unit from AC power source and disconnect all connected equipment.
10. Troubleshooting __________________________________________________________ ____ PROBLEM POSSIBLE CAUSE ACTION TO TAKE On/off/test/silence button not pushed or push too short Press the on/off/test/.
11. Storage __________________________________________________________ ____ 10.1 Storage conditions Store the UPS covered and upright in a cool , dry location, with its battery fully charged.
Typical Recharge Time 4 hours (to 90% of full capacity) Protection Automatic self-test & discharge protection, replace battery indicator Back up Time 10 - 30 minutes (depending on computer load) Net Weight Kg(lbs) 4.7(10.4) 5.8(12.8) 6.2(13.7) 6.5(14.
デバイスPowercom 425Aの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Powercom 425Aをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPowercom 425Aの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Powercom 425Aの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Powercom 425Aで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Powercom 425Aを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPowercom 425Aの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Powercom 425Aに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPowercom 425Aデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。