Powerwareメーカー5115A USBの使用説明書/サービス説明書
ページ先へ移動 of 44
POWER W ARE ® 51 15A USB User ’ s Guide 500-1400 V A www .powerware.com.au.
51 15AUSBManual.qxd Rev 1 © Copyright 2004, Powerware. All rights reserved. Powerware is a registered trademark and Advanced Battery Management (ABM) is a trademark of Powerware Corporation.
POWER W ARE ® 51 15A USB 500-1400 V A User ’ s Guide www .powerware.com.au.
Special Symbols The following are examples of symbols used on the UPS to alert you to important information. CAUTION T o reduce the risk of electric shock, Do not remove cover (or back) No user-servic.
T ABLE OF C ONTENTS 1 Powerware 51 15 -Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2 Inst allation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Inspecting the Equipment . . .
7 T roubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 Audible Alarms and UPS Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 Silencing an Audible Alarm . . . . . . . . . . . .
1 Powerware ® 51 15A USB User’s Guide • www .powerware.com.au Figure 1. Powerware 51 15 CHAPTER 1 P OWERW ARE 51 15 - INTRODUCTION The Powerware 51 15 uninterruptible power system (UPS) protects your sensitive electronic equipment from power problems such as power failures, power sags, power surges, brownouts, and line noise.
2 Powerware ® 51 15A USB User’s Guide • www .powerware.com.au Powerware 51 15 - Introduction Because an integral part of power protection is power management sof tware, the Powerware 51 15 comes .
3 Powerware ® 51 15A USB User’s Guide • www .powerware.com.au CHAPTER 2 I NST ALLA TION This section explains • Equipment inspection • Safety precautions • UPS Installation • UPS rear panels Inspecting the Equipment If the UPS has been damaged during shipment, contact your vendor immediately .
4 Powerware ® 51 15A USB User’s Guide • www .powerware.com.au Installation Inst alling the UPS The following steps explain how to inst all the UPS. Figure 2 shows a typical installation only . See “UPS Rear Panels” on page 6 for the rear p anel of each model.
4. Plug the equipment to be protected into the UPS outlet sockets. DO NOT protect laser printers with the UPS because of the exceptionally high power requirements of the heating element s. 5. S tart the UPS by pressing the button as shown in Figure 2.
6 Powerware ® 51 15A USB User’s Guide • www .powerware.com.au Installation UPS Rear Panels This section shows the rear panels of the Powerware 51 15 models.
7 Powerware ® 51 15A USB User’s Guide • www .powerware.com.au Figure 5. 1000V A Rear Panel Figure 6. 1400V A Rear Panel 3 x 10A Australian Output Receptacles USB Port Network T ransient Protector.
8 Powerware ® 51 15A USB User’s Guide • www .powerware.com.au.
9 Powerware ® 51 15A USB User’s Guide • www .powerware.com.au CHAPTER 3 O PERA TION This section describes • T urning the UPS on and off • S tarting the UPS on battery • S tandby mode • T.
10 Powerware ® 51 15A USB User’s Guide • www .powerware.com.au Operation UPS Front Panel The UPS front panel indicates the UPS st atus and also identifies potential power problems.
11 Powerware ® 51 15A USB User’s Guide • www .powerware.com.au CHAPTER 4 A DDITIONAL UPS F EA TURES This section describes • Using the communication port • Using the USB Port • The Network .
12 Powerware ® 51 15A USB User’s Guide • www .powerware.com.au Additional UPS Features T able 1. Communication Port Pin Assignment USB Port The UPS can communicate with a USB-compliant computer using LanSafe Power Management Software (v5.0 or higher).
13 Powerware ® 51 15A USB User’s Guide • www .powerware.com.au Figure 10 Network T ransient Protector Network T ransient Protector The Network T ransient Protector , shown in Figure 10, is located on the rear panel and has jacks labelled IN and OUT .
14 Powerware ® 51 15A USB User’s Guide • www .powerware.com.au.
15 Powerware ® 51 15A USB User’s Guide • www .powerware.com.au CHAPTER 5 UPS M AINTENANCE This section explains how to: UPS and Battery Care For the best preventive maintenance, keep the area around the UPS clean and dust- free. If the atmosphere is very dusty , clean the outside of the system with a vacuum cleaner .
16 Powerware ® 51 15A USB User’s Guide • www .powerware.com.au UPS Maintenance Replacing Batteries The hot-swappable battery feature allows you to replace the UPS batteries easily without turning the UPS off or disconnecting the load. If you prefer to remove input power to change the battery , press the button and then unplug the UPS.
17 Powerware ® 51 15A USB User’s Guide • www .powerware.com.au Use the following steps to replace the batteries: 1. Pull the top left corner forward and remove the front p anel.
18 Powerware ® 51 15A USB User’s Guide • www .powerware.com.au 4. 750-1400V A unit s. Disconnect the red battery cable and then pull the battery out onto a flat, stable surface.
19 Powerware ® 51 15A USB User’s Guide • www .powerware.com.au 5. Replace the battery . See “Recycling the Used Battery” for proper disposal. 6. Connect the black battery cable to the new battery and then connect the red battery cable. 7. Reinstall the battery .
20 Powerware ® 51 15A USB User’s Guide • www .powerware.com.au.
21 Powerware ® 51 15A USB User’s Guide • www .powerware.com.au CHAPTER 6 S PECIFICA TIONS This section provides the following specifications for the Powerware 51 15 models: • Electrical input and output • Mass and dimensions • Environmental and safety • Battery T able 2.
22 Powerware ® 51 15A USB User’s Guide • www .powerware.com.au Specifications T able 4. Electrical Output Power Levels (rated at 500V A, 320W nominal inputs) 750V A, 500W 1000V A, 670W 1400V A, 950W Power Factor 500V A, 0.
23 Powerware ® 51 15A USB User’s Guide • www .powerware.com.au T able 6. Battery Configuration 500V A: (1) 12V , 9 Ah internal battery 750V A: (2) 12V , 7 or 7.
24 Powerware ® 51 15A USB User’s Guide • www .powerware.com.au.
25 Powerware ® 51 15A USB User’s Guide • www .powerware.com.au CHAPTER 7 T ROUBLESHOOTING If you have a question or problem, the troubleshooting table may help (See T able 8). If you need assistance, phone Powerware Service or your local Powerware of fice.
26 Powerware ® 51 15A USB User’s Guide • www .powerware.com.au T roubleshooting Indicator Legend Lit Flashing T able 8. T roubleshooting Guide Alarm or Condition Possible Cause Action The indicator is not on,. The power cord is not Check the power cord connections.
27 Powerware ® 51 15A USB User’s Guide • www .powerware.com.au T able 8. T roubleshooting Guide (continued) Alarm or Condition Possible Cause Action 1 beep The UPS is running on Correct the input voltage, if possible.
28 Powerware ® 51 15A USB User’s Guide • www .powerware.com.au T able 8. T roubleshooting Guide (continued) Alarm or Condition Possible Cause Action 3 beeps Failed attempt to start the Plug the UPS into a power outlet for 24 hours to every 10 UPS on battery .
29 Powerware ® 51 15A USB User’s Guide • www .powerware.com.au Service and Support If you have a question or problem, T able 8, T roubleshooting Guide, may help. If you need more help, please have your UPS model number and serial number (on the back label) nearby , and call the Powerware National Service and Rep air Centre .
30 Powerware ® 51 15A USB User’s Guide • www .powerware.com.au.
31 Powerware ® 51 15A USB User’s Guide • www .powerware.com.au CHAPTER 8 W ARRANTY I NFORMA TION This W arranty is subject to Eaton Power Quality Pty Ltd (EPQ) standard Conditions of Sale which govern all sales of products by Eaton Power Quality Pty Lt d.
32 Powerware ® 51 15A USB User’s Guide • www .powerware.com.au 7. Providing that the batteries are used within the limits as set out in the battery manufacturer’s warranty statement and are provided as an integral p art of new equipment, they are guaranteed for two years, from despatch date as per invoice.
33 Powerware ® 51 15A USB User’s Guide • www .powerware.com.au Register your warranty on line at www .powerware.com.au within 30 days and receive the T en-Y ear Pro-Rated Warranty and $50,000 Loa.
34 Powerware ® 51 15A USB User’s Guide • www .powerware.com.au Required Operating Conditions and Extended T en-Y ear Pro-Rated Warranty Exclusions 1. If you plan to store the UPS or battery cabinets prior to use, store them in a cool, dry environment.
Eaton Power Quality Pty Ltd 13 Healey Road DANDENONG VIC 3175 AUSTRALIA AFFIX POST AGE ST AMP.
6.Please specify the equipment being protected by your Powerware UPS? Brand........................................Model ..............................
37 Powerware ® 51 15A USB User’s Guide • www .powerware.com.au Powerware Australia/New Zealand Of fices Head Office - Sydney Eaton Power Quality Pty Ltd ABN 82 054 056 709 1 19-127 Wicks Road North Ryde NSW 21 13 Phone: 61-2-9878 5000 Fax: 61-2-9887 2186 National Service and Repair Centre 1300 303 059 Web Site: www .
Powerware ® 51 15A USB User’s Guide • www .powerware.com.au Y ou have purchased a UPS that will provide you with many years of service, protecting your equipment from surges, sags, and blackouts.
デバイスPowerware 5115A USBの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Powerware 5115A USBをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPowerware 5115A USBの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Powerware 5115A USBの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Powerware 5115A USBで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Powerware 5115A USBを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPowerware 5115A USBの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Powerware 5115A USBに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPowerware 5115A USBデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。