Powerware Modbus Card User’s Guide ®®.
Class A EMC Statements FCC Part 15 NOTE This equipment has been tested and found to comply with th e limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environm ent.
EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com i Table of Contents 1 Introduction 1 ......................................................... 2 Installing the Modbus Card 3 ........................................
TABLE OF CONTENTS EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com ii.
EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 1 Chapter 1 Introduction The Eaton ® Powerware ® Modbus ® Card is an X - Slot ® connectivity device that allows you to continuously and reliably monitor the UPSs in your Building Management System (BMS).
INTRODUCTION EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 2 RS-485 Network Power Meter PLC UPS with Modbus Card Ethernet Gateway Building Management Software Ethernet -270.
EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 3 Chapter 2 Installing the Modbus Card The Modbus Card is available: S as a separate card for use with UPSs that have an X - Slot S factory - installed in a Powerware Expansion Chassis Use the following sequence for installing the Modbus Card: 1.
INSTALLING THE MODBUS CARD EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 4 Four-Wire Communication The factory - default setting for the Modbus Card is for two - wire communication. To change the default setting, adjust the jumpers on the Modbus Card.
INSTALLING THE MODBUS CARD EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 5 3. Change the J9 and J10 jumpers to the desired setting as shown in Figure 4. 1 1 J11 23456 ON S2 J7 J8 J10 J9 J9 J10 Four-Wire 1 1 J9 J10 Two-Wire (Default) 1 1 Figure 4.
INSTALLING THE MODBUS CARD EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 6 Installing the Modbus Card into an X-Slot CAUTION To prevent electrostatic discharge (ESD), pl ace one hand on an unpainted metal surface such as the UPS rear panel.
EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 7 Chapter 3 Wiring the Modbus Card The Modbus Card provides an easy path for integrating a Powerware UPS into an RS - 485 Modbus network and also provides isolation of the communication between the UPS and the RS - 485 Modbus network.
WIRING THE MODBUS CARD EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 8 Four-Wire Networks The Modbus Card also supports four - wire, half - duplex, RS - 485 networks. Figure 7 shows a detailed view of four - wire connections using the Modbus Card terminal strip.
WIRING THE MODBUS CARD EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 9 For four-wire networks. All four RS -485 network signals including TxD(+), RxD(+), TxD(–), and RxD(–) must be connected to the terminal strip as illustrated in Table 1.
WIRING THE MODBUS CARD EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 10 3 8 7 9 1 6 2 4 5 Figure 9. RS-485 DB-9 Pin Numbers Table 2.
WIRING THE MODBUS CARD EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 11 1 J11 S2 J7 J8 J10 J9 RxD(–) Pull Down (620 Ω) RxD Terminator (120 Ω) Four-Wire Two.
WIRING THE MODBUS CARD EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 12 RS-232 Modbus Port It is also possible to use the RS - 232 Modbus port for connecting to your network. 3 8 7 9 1 6 2 4 5 Figure 11. RS-232 DB-9 Pin Numbers Table 3.
EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 13 Chapter 4 Modbus Card Configuration The Modbus Card has an RS - 232 configuration port that you can access with a terminal or a computer equipped with a terminal emulation program.
MODBUS CARD CONFIGURATION EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 14 2. Press [Enter]. The Configuration screen appears (see Figure 13).
MODBUS CARD CONFIGURATION EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 15 4. To configure the slave address, type AD followed by a space and node (1 through 247) and press [Enter]. The default is 29. This setting affects both RS - 232 and RS-485 Modbus connections.
MODBUS CARD CONFIGURATION EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 16.
EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 17 Chapter 5 Integrating the UPS Powerware provides a software tool named Modbus Profiler that creates a Modbus register map specifically for your Powerware UPS.
INTEGRATING THE UPS EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 18 5. Run profiler from the command prompt or double - click profiler.exe from Microsoft Windows Explorer. By default, Modbus Profiler uses the communication port specified in the [Connection] section of the profiler.
INTEGRATING THE UPS EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 19 Unit Format Value Name Register 113 Rectifier Input Status 1 BOOL Status 114 Bypass Status 0.
INTEGRATING THE UPS EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 20 Unit Format Value Name Register 162 Building Alarm 2 1 BOOL Status 163 Building Alarm 1 0 BO.
INTEGRATING THE UPS EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 21 Table 5. Read Input Registers - Modbus Function Code 04 (Input Registers Start at 30000) Reg.
INTEGRATING THE UPS EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 22 Unit Scale Meter Name Register 62 INVERTER VOLTS PHASE C /10 Volts 66 LOAD CURRENT PHASE A /.
EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 23 Chapter 6 Troubleshooting Problem Possible Cause Corrective Action The Modbus Profiler tool does not generate the f i l f i l The wrong communication port number was entered in the profiler comX command.
TROUBLESHOOTING EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 24 1 J11 2 13 4 5 6 ON S2 J7 J8 J10 J9 S2 Termination (Default ”OFF”) J11 Half Duplex Full-Duplex (Default) 1 1 J9 J10 Two-Wire (Default) 1 1 Two-Wire/Four-Wire J7 J8 DCE DCE/DTE (Default) 11 Figure 15.
TROUBLESHOOTING EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 25 Service and Support If you have any questions or problems with the Modbus Card, call your Local Distributor or the Help Desk at one of the following telephone numbers and ask for a Modbus Card technical representative.
TROUBLESHOOTING EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 26.
.
*164201376C* 164201376 C.
デバイスPowerware FCC 15の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Powerware FCC 15をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPowerware FCC 15の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Powerware FCC 15の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Powerware FCC 15で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Powerware FCC 15を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPowerware FCC 15の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Powerware FCC 15に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPowerware FCC 15デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。