INSTRUCTION MANUAL BEDIENUNGSANLEITUNG MANUEL D’INSTRUCTIONS VCC-5775P COLOUR CCD camera CCD-Farbkamera Caméra CCD COULEUR CCD About this manual Befor e installin g and using the camer a, please read this manual carefully. Be sure to keep it handy for later reference.
Depending on the conditions of use, installation and environment, please be sure to make the appropriate settings and adjustments. If you need help with installation and/or settings, please consult your dealer. CONTENTS PRECAUTIONS ...................
FEATURES • Built-in interline transfer method 1/3" CCD, approx. 470,000 picture elements • Low smear, anti-blooming, low lag, no burning and no geometric distortion using the CCD solid state image device.
PRECAUTIONS In case of problem Do not use the camera if smoke or a strange odour comes from the unit, or if it seems not to function correctly. Disconnect the power cord immediately, and consult your dealer (or a Sanyo Authorized Service Centre). Do not open or modify Do not open the cabinet, as it may be dangerous and cause damage to the unit.
PRECAUTIONS Protect from high temperatures Do not install close to stoves, or other heat generating devices, such as spotlights, etc., or where it could be subject to direct sunlight, as that could cause deformation, discoloration or other damages.
PARTS NAMES 1 Camera mounting screw hole CAUTION: When installing the camera, select a location that can support the total weight of the camera and accessories.
PARTS NAMES 7 Flange-back lock screw 8 CS mount ring 9 Lens mount cap The cap is installed to protect the lens mount section. Remove the lens mount cap before installing a lens. F Video output connector (VIDEO OUT: BNC type) Connect this connector to a device such as a VCR or monitor with a VIDEO IN connector.
MOUNTING THE LENS Please use a DC type auto-iris lens (sold separately). Checking the lens mount Do not use lense with a length L more than 5 mm. If not, that may damage the camera and prevent proper installation. 1 Remove the lens mount cap from the camera.
MOUNTING THE LENS Pin layout 1 Brake coil (–) 2 Brake coil (+) 3 Drive coil (+) 4 Drive coil (–) Rewiring the lens cable in the lens iris plug 1 Prepare the lens cable. Cut t he c a ble at the plug, t hen r emove approx. 8 mm of the cable shea t h and stri p a b out 2 mm from e a ch wi re.
CONNECTIONS Basic connection for monitoring or recording (Video signal connections) : VIDEO IN : VIDEO OUT AC 24 V connection DC 12 V connection Fig. 1 Fig. 2 + – + DC12V – Push to insert the cable. Note: The polarities for the 24 V AC and the 12 V DC input connectors are indicated on the rating label found on the unit back panel.
CONNECTIONS The peripheral devices (VCR, monitor, lens, etc.) and cables are sold separately. 1 Make the video signal connection between the camera and the monitor or timelapse VCR. 2 Power supply choices • Use a commercially available 24 V AC adaptor.
FLANGE-BACK ADJUSTMENT If the pick-up surface is not correctly positioned with relation to the lens focal point, the picture will be out of focus ( in particular when using auto-iris power zoom lenses, sold separately ). If that is the case, adjust the flange-back position as described below.
SETTINGS Line phase adjustment When using a camera switcher to connect 2 cameras or more to one monitor, there may be a vertical roll of the images when switched. In such a case, set as described below. 1 Set the Sync switch to the L-L position. 2 Switch the display on the monitor from camera 1 to camera 2.
SETTINGS Lens iris adjustment If using a DC type auto-iris lens, you will need to set the LEVEL volume when shooting in the conditions described below. Counterclockwise: To decrease the brightness Clockwise: To increase the brightness • If shooting simultaneously in a dark room and through a bright window.
SETTINGS EI (Electronic iris) function setting Under normal conditions, set the EI switch to the EI OFF position and use an auto-iris lens. However, if you have a manual lens or fixed iris lens, set the lens aperture to the shortest F stop and set the EI switch to the EI ON position.
TROUBLESHOOTING Before tak ing t he camer a for r epairs, p lease c hec k below to make su re that t he ca mera is used cor rectly. If it still does not perform correctl y , p lease cons u lt you r deale r or a Sany o Authori zed Ser v i c e Ce ntre.
SPECIFICATIONS Scanning system: PAL standard (625 TV lines, 25 frames/sec.) Interlace: 2:1 interlace Image device: 1/3 in ch s olid s tate image device C C D Picture elements: 798 (H) x 584 (V) Effect.
SPECIFICATIONS Dimensions: mm Features and specifications are subject to change without prior notice or obligations. 51 63 68 (1) L53V2/ XE (VCC -5775P ) GB 2000, 7 , 11 English 17.
ACCESSORIES 12 1 C mount adaptor (5 mm) ........................ 1 pc. The C mount adaptor must be used to be able to install a C mount lens on the camera.
1AC6P1P2347-- L53V2/XE(0700KP-DSP) Sanyo Electric Co, Ltd. Printed in Japan L53V2/ X E (VCC -5775P) GB 2 000, 7, 11.
デバイスProxima ASA VCC-5775Pの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Proxima ASA VCC-5775Pをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはProxima ASA VCC-5775Pの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Proxima ASA VCC-5775Pの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Proxima ASA VCC-5775Pで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Proxima ASA VCC-5775Pを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はProxima ASA VCC-5775Pの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Proxima ASA VCC-5775Pに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちProxima ASA VCC-5775Pデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。