PSCメーカーQS200の使用説明書/サービス説明書
ページ先へ移動 of 48
QS200 Pr ogramming Man ual v 2.1 Handheld Scanner.
PSC Inc 959 T erry Street Eugene , Oregon 97402 T elephone: ( 541) 683-5 700 F ax: (541) 34 5-71 40 All rights re serve d. N o pa rt of the cont ents of this d ocu me nta t ion or th e p rocedures desc ribed t herein ma y be produ ced or transmit ted in any f or m or by any means wit h out p r ior wr itt en per mi ssion of PSC Inc.
TABL E OF CON TENTS Introduc tion F l o w C h a r t 1 Interfaces 2 On/Off Symb ologies 3 Code 39 7 Codaba r/NW7 8 Interl eaved 2/5 9 Standard 2/5 11 M a t r i x 2 / 5 1 2 EAN-13/EAN-8 13 UPC-A/UPC-E 1.
RS232 Parameters 28 CC D Wa nd Emulation 31 OCIA Types 32 Magnetic Setting 33 Code Mark 34 Truncate D igits 36 ASCII Table 38 Hexadec im al Labels 39 Pinout Assignments 40 Notes: 1. Options marked by { } are only ava ilable for some models. 2. Factory defa ult values are indicated by .
INTRODUCT ION Bar Code devices p rovide an accurate, easy, and fast m ethod of data entry and data storage for c omputerized infor m ation systems. The products we ar e offering now ca n be integ rate.
-1- FL OW CHART START OF CONFIGURATION ABORT CONFIGURATION * SELECT INTERFACES SELECT SYMBOLOGIES OPERATION PARAMETERS END OF CONFIGURATION ** SET FACTORY DEFAULTS ** SHOW VERSION * Rej ect new set tings & end.
INTERFACES - 2 - KEYBOARD RS232C CC D WAND EM UL ATION {OCIA} RESERVED 1 RESERVED 2 To choose an Interface, e.g. KEYBOARD: 1. Scan START OF CONFI GURATION 2.
- 3 - SYMBOLOGIES CODE 39 OFF ON INTERLEAVED 2 OF 5 OFF O N STANDAR D 2 OF 5 OFF O N.
SY MBOLOGIES - 4 - EAN- 8 OFF ON EAN -13/UPC-A OFF ON UPC-E OFF ON ISBN/ISSN .
- 5 - SYMBOLOGIES CODE 128 OFF ON CODE 93 OFF O N CHINESE 2 OF 5 OFF O N {MSI/PL ESSEY} .
SY MBOLOGIES- 6 - {PHARMACEUTIC AL COD E} OFF O N {CODE IV} OFF O N {CODE49} OFF O N Ita.
- 7 - CODE 3 9 TYPE STANDA RD FULL ASCII TRANSMIT ST ART / ST OP CHAR OFF O N VERIFY CHECKSUN OFF .
CODABAR/NW 7 - 8 - TRANSMIT ST ART /ST O P OFF O N TYP E OF ST ART/ST OP ABCD/ ABCD A B C D / T N E abcd/abcd .
- 9 -INTE RLEAVED 2 OF 5 BAR CODE L ENGTH MINI. TO M AXI. = ? <6-32> MINI.=2 . MAXI.=32 CUSTOM DE FINE 3 SETS AVAILABLE TRANSMIT CHECK DIGIT .
INTERLEAVED 2 OF 5- 10 - To choose BAR COD E LENGTH, e.g. 10 - 20, (0A,1 4 in Hex): 1. Scan START OF CONFIGURATION 2. Scan BAR CODE LENGTH 3. Scan 0 A 1 4 SET 4. Scan END OF CONFI GURATION CUSTOM DEFINE, user m ay choose 1 to 3 indiv id ual lengths, exclud ing the range between, e.
- 11 - STANDARD 2 OF 5 BAR CODE L ENGTH MINI. TO M AXI. = ? <6-32> MINI.=2 . MAXI.=32 CUSTOM DE FINE 3 SETS AVAILABLE TRANSMIT CHECK DIGIT .
M A TRIX 2 OF 5- 12 - BAR CODE LENGTH MINI. TO M AXI. = ? <6-32> MINI.=2 . MAXI.=32 CUSTOM DE FINE 3 SETS AVAILABLE TRANSMIT CHECK DIGIT OFF .
- 13 - EAN-13/EAN-8 EAN-13 T RUNCATE LEADING DIGIT S = ? 0 TRANSMIT CHECK DIGIT YES N O EAN- 8 T RUNCATE LEADING DIGIT S = ? 0 TRANSMIT CHECK DIGIT YES N O Ex am pl e: user wants to truncate 1 (the f irst leadin g d ig it): 1.
UPC-A/UPC-E - 14 - UPC-A T RUNCATE LEADING DIGIT S = ? 0 TRANSMIT CHECK DIGIT YES N O UPC-E TRUNCATE LEADING DIGIT S = ? 0 TRANSMIT CHEC.
- 15 - CHINESE 2 OF 5 BAR CODE L ENGTH MINI. TO M AXI. = ? <6-32> MINI.=2. M AXI.=32 CUSTOM DE FINE 3 SETS AVAILABLE TRANSMIT CHECK DIGIT OFF .
READING MOD ES - 16 - TRIGGER ON/OFF T RIGGER ON/ GOOD READ OFF CONTINUOUS/ TRIGGER OFF CONTINUOUS/ LED AL WAYS ON TESTI.
- 17 - G ENERAL PARAMETERS TERMINAT OR NONE CR KB LF C R / L F RS232 SPACE T A B ESC CTRL- C EXEC STX. .ET X EOT LED INDICATOR OFF ON.
GENERAL PARAME TERS - 18 - TERMINAT OR DELAY = ? <4> KEYBOARD <0> RS232 BUZZER PITC H = ? <18> BUZZER <5> DURATION = ? TI ME(S) .
- 19 - G ENERAL PARAMETERS CHARACTER DELAY = ? <4> KEYBOARD <0> RS232 INTERFIELD DELAY = ? <20> SENDING NUM BER OF DIG ITS OFF .
KEYBO ARD P A RAMETERS - 20 - LOW ER CASE UPPER CASE NUMBER KEYS ALPHANUM NUMLOCK PAD KEYBO ARD SPEED NORMAL T U R B.
- 21 - TERMINAL TYPE PC/AT, " PS/2 30- 80 PC/XT " PS/2 25,30 " IB M5541 IBM PS/55 ST " IBM 3472,3477 IBM 5530- SC IBM PS/55 MP .
TERMINAL TYPE- 22 - {Mac II,SE} " {W YSE} " {ACER D7300} " {W ANG} " {THINK PAD} "# IBM.
- 23 - FUNCTION KEY FUNCTION KEY EMULATION ENABLE DISABLE Scanner ca n read Function keys and other special keys, please refer to FUNCTION KEY LA BL ES. When doing this, Code 39 FUL L ASCII must be on. To concatenate a F unctio n Key or other special keys wit h input data, e.
FUNCTIO N KEY TABLE - 24 - H L 0 1 0 BkSp 1 F1 Hom e 2 F2 PgUp 3 F3 PgDn 4 F4 END 5 F5 6 F6 7 F7 8 F8 9 F9 Ins A F10 Del B F1 1 Pad C F12 D Etr E ESC F TAB.
-25- F UNCTION KEY LABELS F1 F 2 F 3 F4 F 5 F6 F7 F 8 F 9 F10 F 1 1 F 12 Ente r E S C T A B BkSp H o m e P g U p.
FUNCTION KEY LABELS -26- PgDn E n d Ins D e l P a d.
- 27 - LANGUAGES $ BELGIAN $ D A N I S H $ FRENCH $ G E R M A N Y $ ITALIAN $ PORTUGUESE $ SPANISH $.
RS232 P ARAMETERS - 28 - BAUD RATE ! 300 ! 6 0 0 ! 1200 ! 2400 ! 4800 ! 9600 ! 19200 ! 3.
- 29 - RS232 PA RAMETERS PARITY & NONE & ODD & SPACE & EVEN & MARK HAND SHAKING NONE .
RS232 P A RAMETERS - 30 - ACK/NAK Response T ime CTS Observation T i me 300 msec 500 msec 1 sec 2 sec 3 sec .
- 31 - CC D WAN D EMULATION ' BAR=HIGH ' B A R = L O W SCAN S PEED SLOW EST ' (28c m/sec) SLOW ' (36c m/sec) NORMAL ' (49c m/sec) HIGH ' (80c m/sec) HIGHEST ' (208 cm/sec) BASE ON 0.
OCIA - 32 - OCIA MAC HINES " CASIO " SIEMENS " NIXDORF " NCR-S &quo.
- 33 - MAGNET I C SETTING TRACK DEL IMIT ER NONE CR LF C R / L F .
CODE MARK- 34 - ( CODE 39 = ? ( I T F 2 / 5 = ? ( STD 2/5 = ? ( M T X 2 / 5 = ? ( CODABAR = ? ( E A N - 1 3 = ? .
- 35 - CODE MARK ( {CODE IV} ( {PHARMACEUTIC AL} CODE MAR K CANCELLATION ! * Read code type first CODE MARK ON O.
TRUNCATE LEADING DIGIT - 36 - CODE 39 CODABAR MATRIX 2/5 STANDA RD 2/5 INTERLEAVED 2/5 CODE 128 .
- 37 - TRUNCATE ENDING DIGIT CODE 39 CODABAR MATRIX 2/5 STANDA RD 2/5 INTERLEAVED 2/5 CODE 128 CODE .
ASCII TABLE - 38 - START CONFIGURATION ABORT CONFIGURATION END CONFIGURAT ION ASCII TABL E H L 0 1 2 3 4 5 6 7 0 NUL DLE SP 0 @ P &.
- 39 - HEXADE CIMAL LABELS 0 1 2 3 4 5 6 7 .
PIN ASSIG NMENTS - 40 - TTL Si gnal Output COLOR FUN CTION 9 PIN DSUB/AMP (F) 5 PIN DIN (M) 6 PIN DIN (M) 6 PIN MI NI DIN (M) BROW START O F SCAN 1 - 6 6 YELL O SIG ANLDATA 2 2 2 4 GREEN LED INDICATOR.
- 41 - PIN ASSIG NMENTS RS232 SIGNAL O UTPUT COLOR FUN CTION 9 PIN DSUB/AM P (F) 25 PIN DSUB (F) BROW GND 5 7 YELL O CTS 8 4 GREEN RT S 7 5 ORANG E RX 2 2 BLU E TX 3 3 PURPLE Vcc +5V 9 25,16.
PIN ASSIG NMENTS - 42 - RS232/Keyboard Signal Output COLOR FUN CTION 9 PIN DSUB/AM P (F) 25 PIN DSUB (F) BROW GND 5 7 BLU E TX 3 3 PURPLE Vcc +5V 9 25,16 ORANG E RX 2 2 NOTE: RS232 CAB LE WITH DC POWE.
Asia Pacifi c PSC Hong K ong Hong K ong T elephone: [852]-2-584-6210 F ax: [852]-2-5 21-0291 Au s t r a l i a PSC Asia P acific Pty Ltd. Nor th Ryde, A ustralia T elephone: [61] 0 (2) 9878 8999 F ax: [61] 0 (2 ) 9878 8688 France PSC S.A.R.L. LES ULIS Cede x, F rance T elephone: [33].
デバイスPSC QS200の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
PSC QS200をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPSC QS200の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。PSC QS200の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。PSC QS200で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
PSC QS200を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPSC QS200の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、PSC QS200に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPSC QS200デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。