Switch Interoperability WWW.QLOGIC.COM SAN QLOGIC PRESS QLOGIC PRESS SN0135524-00 Rev A 3/03 THE ONLY SOURCE FOR MULTI-VENDOR INTEROPERABILITY v 1 3/2003 Switch Interoperability 3 / 03 v1 GUIDE SANbox ™ Guide QLogic end-to-end solutions i n c lude industry-leading controller chips, host bus adapters, network switc hes and management software.
.
QLogic Switch Interoperability Guide V ersion 1.0.
P AGE II QL OGIC S WITCH I NTEROP ERABI LITY G UIDE V ERSION 1.0, M ARCH 200 3 Copyright © 2002 QLogic Corpora t ion. All rights reserved. QLogic C orpora tion and i ts strategic Partners, he nceforth known as the " Partners," h ave agreed to pro vide a s witch interope rability referenc e docu ment.
QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E III V ERSION 1.0, M ARCH 2003 McDA T A, the McDA T A logo, and S phereon are trademark s or reg istered tra demarks of Mc DA T A Corporation in the United S tates, other coun tries, or both.
P AGE IV QL OGIC S WITCH I NTEROP ERABI LITY G UIDE V ERSION 1.0, M ARCH 200 3.
QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E V V ERSION 1.0, M ARCH 2003 T ab le of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Supported Switch es and Firm ware Versions .
Table o f Contents P AGE VI QL OGIC S WITCH I NTEROP ERABI LITY G UIDE V ERSION 1.0, M ARCH 200 3 Succe ssfu l Int egra tion Chec klist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 9 Merging QLogic and Cisco Fabrics .
Table of Cont ents QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E VII V ERSION 1.0, M ARCH 2003 Doma in ID Con figur ation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 3 Timeout Values . . . . . . . .
Table o f Contents P AGE VI II QL OGIC S WITCH I NTER OPERA BILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Opera ting Mode Co nfigur ation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214 McDA TA S pecif ic C onfigu ratio n .
Table of Cont ents QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE IX V ERSION 1.0, M ARCH 2003 Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293 Index . . . . . . . . . . .
Table o f Contents P AGE X QL OGIC S WITCH I NTEROP ERABI LITY G UIDE V ERSION 1.0, M ARCH 200 3.
QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 1 V ERSION 1.0, M ARCH 2003 Introduc tion The QLogic Swit ch Interoperabi lity Guide pro vides the det ails needed to configure and deploy multi-vendor switched fabric s.
Introductio n P AGE 2Q L OGIC S WITCH I NTEROP ERABI LITY G UIDE V ERSION 1.0, M ARCH 200 3.
QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 3 V ERSION 1.0, M ARCH 2003 Supported Switch es and F irmware V ersions The followi ng QLogic switches have been tested in th e QLogic environment and comply with the FC-SW -2 standard.
Suppo rted Swit ches and Firmwa re Ve rsions P AGE 4Q L OGIC S WITCH I NTEROP ERABI LITY G UIDE V ERSION 1.0, M ARCH 200 3.
QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 5 V ERSION 1.0, M ARCH 2003 How to Use this Guide The QLogic Swit ch Interoperabi lity Guide pro vides det ailed swit ch config uration dat a and ste.
How to Use t his Guide P AGE 6Q L OGIC S WITCH I NTEROP ERABI LITY G UIDE V ERSION 1.0, M ARCH 200 3 V isual Representation of How the Chapters Are Organized Brocade SilkWorm 3200 and Sil kWorm 3800 Switches Domain ID Configuration P AGE 14 QL OGIC S WITCH I NTEROPERABILIT Y G UIDE V ERSION 1.
QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 7 V ERSION 1.0, M ARCH 2003 Merging QLogi c and Br ocade Fa brics The followi ng QLogic switches have been tested in th e QLogic environment and comply with the FC-SW -2 standar d.
Merging QLogic and Broc ade Fab rics P AGE 8Q L OGIC S WITCH I NTEROP ERABI LITY G UIDE V ERSION 1.0, M ARCH 200 3.
QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 9 V ERSION 1.0, M ARCH 2003 Brocad e SilkWorm 3200 and SilkWorm 3800 Switches Integration Checklist The followi ng steps must be complet ed to successfull y merge Brocade and QLogic fabri cs. The remainder of th is section provides det ailed inst ructions and example s .
Brocad e SilkW orm 3200 and S ilkWorm 3 800 Switc hes Conf igurat ion Limita tio ns P AGE 10 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Configuration Lim it ations The confi guration l imit ations ar e as f ollows: ■ The followi ng Brocade soft ware implement ations may not be supporte d in QLogic fabrics.
Brocad e SilkW orm 3200 and Si lkWor m 3800 Swi tches Doma in I D Con figur ation QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 11 V ERSION 1.0, M ARCH 2003 Domain ID Configur ation T o ensure that there are no conflict s between switches, we re commend that each switc h have an assigned Domain ID.
Brocad e SilkW orm 3200 and S ilkWorm 3 800 Switc hes Domain ID Co nfigurat ion P AGE 12 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 3. From the Swi tch Admin for Brocade dial og box, sel ect the Switch Set tings tab. Do the following: a.
Brocad e SilkW orm 3200 and Si lkWor m 3800 Swi tches Doma in I D Con figur ation QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 13 V ERSION 1.0, M ARCH 2003 Brocade CLI NOTE: Use the following CLI commands when Brocade’ s Web tools are not availabl e.
Brocad e SilkW orm 3200 and S ilkWorm 3 800 Switc hes Domain ID Co nfigurat ion P AGE 14 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 QLogic SANbox Manager GUI 1. S tart the SANbox Manager applicat ion. The SANbox Manager — Faceplate dial og box displays .
Brocad e SilkW orm 3200 and Si lkWor m 3800 Swi tches Doma in I D Con figur ation QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 15 V ERSION 1.0, M ARCH 2003 For the QLogic SANbox2- 64, the follow.
Brocad e SilkW orm 3200 and S ilkWorm 3 800 Switc hes Domain ID Co nfigurat ion P AGE 16 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 3. From the Swi tch Properties — SANbox Manager dialog box, do the following : a. In the Doma in ID box, type a unique Domain ID for the switch .
Brocad e SilkW orm 3200 and Si lkWor m 3800 Swi tches Doma in I D Con figur ation QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 17 V ERSION 1.0, M ARCH 2003 Qlogic CLI NOTE: Use the CLI commands when the QLogi c SANbox Manag er GUI is not ava ilable.
Brocad e SilkW orm 3200 and S ilkWorm 3 800 Switc hes Timeout Value s P AGE 18 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Ti meout V alues As per FC-SW -2 Fibre Channel s.
Brocad e SilkW orm 3200 and Si lkWor m 3800 Swi tches Timeout V alues QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 19 V ERSION 1.0, M ARCH 2003 3. From the Swi tch Admin for Brocade dial og box, sel ect the Configure t ab. V erify that R_A_TOV is set to 10000 and E_D_T O V is se t to 2000 .
Brocad e SilkW orm 3200 and S ilkWorm 3 800 Switc hes Timeout Value s P AGE 20 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Brocade CLI Login: admin Password: xxxxxxxx Brocade3800:admin> configshow Use the above command to verify that R_A_TOV is set to 10000 and E_D_T OV is set to 2000.
Brocad e SilkW orm 3200 and Si lkWor m 3800 Swi tches Timeout V alues QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 21 V ERSION 1.0, M ARCH 2003 QLogic SANbox Manager GUI A TTENTION!! The foll owing step s take the switch of fline; theref ore, do not perfor m them on a switch being managed in-band .
Brocad e SilkW orm 3200 and S ilkWorm 3 800 Switc hes Timeout Value s P AGE 22 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 For the QLogic SANbox2- 64, the following displays: 3. From the Switch Propert ies — SANbox Manager dialog box , veri fy that R_A_T OV is set to 10000 and E_D_TO V is set to 2000 .
Brocad e SilkW orm 3200 and Si lkWor m 3800 Swi tches Timeout V alues QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 23 V ERSION 1.0, M ARCH 2003 For the QLogic SANbox2- 64, the following displays: 4. From the Switc h Properties — SANbox Manager dialog box Administrative St ate list, se lect offline .
Brocad e SilkW orm 3200 and S ilkWorm 3 800 Switc hes Princ ipal S witch Configu ratio n P AGE 24 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 QLogic CLI NOTE: Use the CLI commands when the QLogi c SANbox Manag er GUI is not ava ilable.
Brocad e SilkW orm 3200 and Si lkWor m 3800 Swi tches Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 25 V ERSION 1.0, M ARCH 2003 Zone Configuration This section disc usses configuri ng active Zone Set names and Zone types. Active Zone Set Names The Zone and Zone Set n am es on each switch must be un ique.
Brocad e SilkW orm 3200 and S ilkWorm 3 800 Switc hes Zone Con figuratio n P AGE 26 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 3.
Brocad e SilkW orm 3200 and Si lkWor m 3800 Swi tches Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 27 V ERSION 1.0, M ARCH 2003 QLogic SANbox Manager GUI 1. S tart the SANbox Manager applicat ion. The SANbox Manager — Faceplate dial og box displays .
Brocad e SilkW orm 3200 and S ilkWorm 3 800 Switc hes Zone Con figuratio n P AGE 28 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 For the QLogic SANbox2- 64, the following d.
Brocad e SilkW orm 3200 and Si lkWor m 3800 Swi tches Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 29 V ERSION 1.0, M ARCH 2003 3.
Brocad e SilkW orm 3200 and S ilkWorm 3 800 Switc hes Zone Con figuratio n P AGE 30 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 For the QLogic SANbox2- 64, the following displays: QLogic CLI NOTE: Use the CLI commands when the QLogi c SANbox Manag er GUI is not ava ilable.
Brocad e SilkW orm 3200 and Si lkWor m 3800 Swi tches Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 31 V ERSION 1.0, M ARCH 2003 Zone T y pes All zone members must be specified by a w orld wide port name (WWPN) in orde r to comply with Fibre Channe l st andards.
Brocad e SilkW orm 3200 and S ilkWorm 3 800 Switc hes Zone Con figuratio n P AGE 32 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 3.
Brocad e SilkW orm 3200 and Si lkWor m 3800 Swi tches Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 33 V ERSION 1.0, M ARCH 2003 QLogic SANbox Manager GUI 1. S tart the SANbox Manager applicat ion. The SANbox Manager — Faceplate dial og box displays .
Brocad e SilkW orm 3200 and S ilkWorm 3 800 Switc hes Zone Con figuratio n P AGE 34 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 For the QLogic SANbox2- 64, the following d.
Brocad e SilkW orm 3200 and Si lkWor m 3800 Swi tches Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 35 V ERSION 1.0, M ARCH 2003 3. The Edit Zoning — SANbox Manager dialog box displays. Conf irm that all zone memb ers are list ed as WWN.
Brocad e SilkW orm 3200 and S ilkWorm 3 800 Switc hes Zone Con figuratio n P AGE 36 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 For the QLogic SANbox2- 64, the following displays: QLogic CLI NOTE: Use the CLI commands when the QLogi c SANbox Manag er GUI is not ava ilable.
Brocad e SilkW orm 3200 and Si lkWor m 3800 Swi tches Brocade Specifi c Configu ratio n QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 37 V ERSION 1.0, M ARCH 2003 Operating Mod e Configur ation The Brocade switch must be in I nteroperabil ity mode to be FC-SW2 compliant.
Brocad e SilkW orm 3200 and S ilkWorm 3 800 Switc hes QLogic Specifi c Configu ratio n P AGE 38 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.
QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 39 V ERSION 1.0, M ARCH 2003 Brocade SilkWorm 3900 and SilkWorm 12000 Switche s Integration Checklist The followi ng steps must be complet ed to successfull y merge Brocade and QLogic fabri cs. The remainder of th is section provides det ailed inst ructions and example s .
Brocad e SilkW orm 3900 and Sil kWorm 1 2000 Switc hes Conf igurat ion Limita tio ns P AGE 40 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Configuration Lim it ations The confi guration l imit ations ar e as f ollows. ■ The followi ng Brocade soft ware implement ations may not be supporte d in QLogic fabrics.
Broc ade SilkW orm 3900 and SilkWo rm 12000 Swi tches Doma in I D Con figur ation QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 41 V ERSION 1.0, M ARCH 2003 Domain ID Configur ation T o ensure that there are no conflict s between switches, we re commend that each switc h have an assigned Domain ID.
Brocad e SilkW orm 3900 and Sil kWorm 1 2000 Switc hes Domain ID Co nfigurat ion P AGE 42 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 3. From the Swi tch Admin for Brocade dial og box, sel ect the Switch Set tings tab. Do the following: a.
Broc ade SilkW orm 3900 and SilkWo rm 12000 Swi tches Doma in I D Con figur ation QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 43 V ERSION 1.0, M ARCH 2003 Brocade CLI NOTE: Use the following CLI commands when Brocade’ s Web tools are not availabl e.
Brocad e SilkW orm 3900 and Sil kWorm 1 2000 Switc hes Domain ID Co nfigurat ion P AGE 44 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 QLogic SANbox Manager GUI 1. S tart the SANbox Manager applicat ion. The SANbox Manager — Faceplate dial og box displays .
Broc ade SilkW orm 3900 and SilkWo rm 12000 Swi tches Doma in I D Con figur ation QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 45 V ERSION 1.0, M ARCH 2003 For the QLogic SANbox2- 64, the follow.
Brocad e SilkW orm 3900 and Sil kWorm 1 2000 Switc hes Domain ID Co nfigurat ion P AGE 46 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 3. From the Swi tch Properties — SANbox Manager dialog box, do the following : a. In the Doma in ID box, type a unique Domain ID for the switch .
Broc ade SilkW orm 3900 and SilkWo rm 12000 Swi tches Doma in I D Con figur ation QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 47 V ERSION 1.0, M ARCH 2003 Qlogic CLI NOTE: Use the CLI commands when the QLogi c SANbox Manag er GUI is not ava ilable.
Brocad e SilkW orm 3900 and Sil kWorm 1 2000 Switc hes Timeout Value s P AGE 48 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Ti meout V alues As per FC-SW -2 Fibre Channel .
Broc ade SilkW orm 3900 and SilkWo rm 12000 Swi tches Timeout V alues QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 49 V ERSION 1.0, M ARCH 2003 3. From the Swi tch Admin for Brocade dial og box, sel ect the Configure t ab. V erify that R_A_TOV is set to 10000 and E_D_T O V is se t to 2000 .
Brocad e SilkW orm 3900 and Sil kWorm 1 2000 Switc hes Timeout Value s P AGE 50 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Brocade CLI Fabric OS (cp1) cp1 login: admin Password: xxxxxxxx Brocade12000:admin> configshow Use the above command to verify that R_A_TOV is set to 10000 and E_D_T OV is set to 2000.
Broc ade SilkW orm 3900 and SilkWo rm 12000 Swi tches Timeout V alues QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 51 V ERSION 1.0, M ARCH 2003 QLogic SANbox Manager GUI A TTENTION!! The foll owing step s take the switch of fline; theref ore, do not perfor m them on a switch being managed in-band .
Brocad e SilkW orm 3900 and Sil kWorm 1 2000 Switc hes Timeout Value s P AGE 52 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 For the QLogic SANbox2- 64, the following displays: 3. From the Switch Propert ies — SANbox Manager dialog box , veri fy that R_A_T OV is set to 10000 and E_D_TO V is set to 2000 .
Broc ade SilkW orm 3900 and SilkWo rm 12000 Swi tches Timeout V alues QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 53 V ERSION 1.0, M ARCH 2003 For the QLogic SANbox2- 64, the following displays: 4. From the Switc h Properties — SANbox Manager dialog box Administrative St ate list, se lect offline .
Brocad e SilkW orm 3900 and Sil kWorm 1 2000 Switc hes Princ ipal S witch Configu ratio n P AGE 54 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 QLogic CLI NOTE: Use the CLI commands when the QLogi c SANbox Manag er GUI is not ava ilable.
Broc ade SilkW orm 3900 and SilkWo rm 12000 Swi tches Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 55 V ERSION 1.0, M ARCH 2003 Zone Configuration This section disc usses configuri ng active Zone Set names and Zone types. Active Zone Set Names The Zone and Zone Set n am es on each switch must be un ique.
Brocad e SilkW orm 3900 and Sil kWorm 1 2000 Switc hes Zone Con figuratio n P AGE 56 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 3.
Broc ade SilkW orm 3900 and SilkWo rm 12000 Swi tches Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 57 V ERSION 1.0, M ARCH 2003 Brocade CLI NOTE: Use the following CLI commands when Brocade’ s Web tools are not availabl e.
Brocad e SilkW orm 3900 and Sil kWorm 1 2000 Switc hes Zone Con figuratio n P AGE 58 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 QLogic SANbox Manager GUI 1. S tart the SANbox Manager applicat ion. The SANbox Manager — Faceplate dial og box displays .
Broc ade SilkW orm 3900 and SilkWo rm 12000 Swi tches Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 59 V ERSION 1.0, M ARCH 2003 For the QLogic SANbox2- 64, the following disp.
Brocad e SilkW orm 3900 and Sil kWorm 1 2000 Switc hes Zone Con figuratio n P AGE 60 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 3.
Broc ade SilkW orm 3900 and SilkWo rm 12000 Swi tches Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 61 V ERSION 1.0, M ARCH 2003 For the QLogic SANbox2- 64, the following displays: QLogic CLI NOTE: Use the CLI commands when the QLogi c SANbox Manag er GUI is not ava ilable.
Brocad e SilkW orm 3900 and Sil kWorm 1 2000 Switc hes Zone Con figuratio n P AGE 62 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Zone T y pes All zone members must be specified by a w orld wide port name (WWPN) in orde r to comply with Fibre Channe l st andards.
Broc ade SilkW orm 3900 and SilkWo rm 12000 Swi tches Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 63 V ERSION 1.0, M ARCH 2003 3.
Brocad e SilkW orm 3900 and Sil kWorm 1 2000 Switc hes Zone Con figuratio n P AGE 64 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 QLogic SANbox Manager GUI 1. S tart the SANbox Manager applicat ion. The SANbox Manager — Faceplate dial og box displays .
Broc ade SilkW orm 3900 and SilkWo rm 12000 Swi tches Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 65 V ERSION 1.0, M ARCH 2003 For the QLogic SANbox2- 64, the following disp.
Brocad e SilkW orm 3900 and Sil kWorm 1 2000 Switc hes Zone Con figuratio n P AGE 66 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 3. The Edit Zoning — SANbox Manager dialog box displays. Conf irm that all zone memb ers are list ed as WWN.
Broc ade SilkW orm 3900 and SilkWo rm 12000 Swi tches Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 67 V ERSION 1.0, M ARCH 2003 For the QLogic SANbox2- 64, the following displays: QLogic CLI NOTE: Use the CLI commands when the QLogi c SANbox Manag er GUI is not ava ilable.
Brocad e SilkW orm 3900 and Sil kWorm 1 2000 Switc hes Operating Mode Confi guration P AGE 68 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Operating Mod e Configur ation The Brocade switch must be in I nteroperabil ity mode to be FC-SW2 compliant.
Broc ade SilkW orm 3900 and SilkWo rm 12000 Swi tches Succes sful I ntegratio n Chec klist QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 69 V ERSION 1.0, M ARCH 2003 Successful I ntegration Checkl ist Perform the follo wing steps af ter the E-port connection has been est ablished and the fabric has had time to update.
Brocad e SilkW orm 3900 and Sil kWorm 1 2000 Switc hes Succes sful Integr ation Checkl ist P AGE 70 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.
QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 71 V ERSION 1.0, M ARCH 2003 Merging QLo gic and Cisco Fabrics The followi ng QLogic switches have been tested in th e QLogic environment and comply with the FC-SW -2 standar d.
Merging QLogic and Cisc o Fabr ics P AGE 72 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3.
QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 73 V ERSION 1.0, M ARCH 2003 Cisco SN 5428 Storage Rou ter Integration Checklist The followi ng steps must be complet ed to successfull y merge Cisco and QLogic fab rics. The remainder of th is section provides det ailed inst ructions and example s .
Cisco SN 5428 Storag e Router Suppo rted Swit ches and Firmwa re Ve rsions P AGE 74 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Supported Switches and Firmware V ersions The followi ng QLogic switches have been tested in th e QLogic environment and comply with the FC-SW -2 st andard.
Cisco SN 5428 Stor age Rou ter Doma in I D Con figur ation QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 75 V ERSION 1.0, M ARCH 2003 Domain ID Configur ation T o ensure that there are no conflict s between switches, we re commend that each switc h have an assigned Do main ID.
Cisco SN 5428 Storag e Router Domain ID Co nfigurat ion P AGE 76 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Cisco CLI NOTE: Use the following CLI commands when the Cisco SN 5428 Management Inter face is not availabl e. A TTENTION!! This proc edure requires a reboo t of the switch.
Cisco SN 5428 Stor age Rou ter Doma in I D Con figur ation QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 77 V ERSION 1.0, M ARCH 2003 QLogic SANbox Manager GUI 1. S tart the SANbox Manager applicat ion. The SANbox Manager — Faceplate dial og box displays .
Cisco SN 5428 Storag e Router Domain ID Co nfigurat ion P AGE 78 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 For the QLogic SANbox2- 64, the following displays:.
Cisco SN 5428 Stor age Rou ter Doma in I D Con figur ation QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 79 V ERSION 1.0, M ARCH 2003 3. From the Swi tch Properties — SANbox Manager dialog box, do the following : a. In the Doma in ID box, type a unique Domain ID for the switch .
Cisco SN 5428 Storag e Router Domain ID Co nfigurat ion P AGE 80 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Qlogic CLI NOTE: Use the CLI commands when the QLogi c SANbox Manag er GUI is not ava ilable. The procedures are t he same for the QLogic SANbox2-8, SANbox2-16, and SANbox2-64.
Cisco SN 5428 Stor age Rou ter Timeout V alues QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 81 V ERSION 1.0, M ARCH 2003 Ti meout V alues As per FC-SW -2 Fibre Channel standards, set a l l swit .
Cisco SN 5428 Storag e Router Timeout Value s P AGE 82 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 QLogic SANbox Manager GUI A TTENTION!! The foll owing step s take the switch of fline; theref ore, do not perfor m them on a switch being managed in-band .
Cisco SN 5428 Stor age Rou ter Timeout V alues QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 83 V ERSION 1.0, M ARCH 2003 For the QLogic SANbox2- 64, the following displays: 3. From the Switch Propert ies — SANbox Manager dialog box , veri fy that R_A_T OV is set to 10000 and E_D_TO V is set to 2000 .
Cisco SN 5428 Storag e Router Timeout Value s P AGE 84 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 For the QLogic SANbox2- 64, the following displays: 4. From the Switc h Properties — SANbox Manager dialog box Administrative St ate list, se lect offline .
Cisco SN 5428 Stor age Rou ter Princi pal S witch Configu ratio n QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 85 V ERSION 1.0, M ARCH 2003 QLogic CLI NOTE: Use the CLI commands when the QLogi c SANbox Manag er GUI is not ava ilable. The procedures are t he same for the QLogic SANbox2-8, SANbox2-16, and SANbox2-64.
Cisco SN 5428 Storag e Router Zone Con figuratio n P AGE 86 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Zone Configuration This section disc usses configuri ng active Zone Set names and Zone types. Active Zone Set Names The Zone and Zone Set n am es on each switch must be un ique.
Cisco SN 5428 Stor age Rou ter Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 87 V ERSION 1.0, M ARCH 2003 QLogic SANbox Manager GUI 1. S tart the SANbox Manager applicat ion. The SANbox Manager — Faceplate dial og box displays .
Cisco SN 5428 Storag e Router Zone Con figuratio n P AGE 88 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 For the QLogic SANbox2- 64, the following displays:.
Cisco SN 5428 Stor age Rou ter Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 89 V ERSION 1.0, M ARCH 2003 3. From the Edit Zoning — SANbox Manager dialog box, comp are the Z.
Cisco SN 5428 Storag e Router Operating Mode Confi guration P AGE 90 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 For the QLogic SANbox2- 64, the following displays: QLogic CLI NOTE: Use the CLI commands when the QLogi c SANbox Manag er GUI is not ava ilable.
Cisco SN 5428 Stor age Rou ter Cisc o Spe cif ic Co nfi gur ati on QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 91 V ERSION 1.0, M ARCH 2003 Cisco S pecific C onfiguration Set the Zoning Merge t ype to SW2. Cisco SN 5428 Management Interface 1. S tart the Cisco SN 5428 Management Interface.
Cisco SN 5428 Storag e Router QLogic Specifi c Configu ratio n P AGE 92 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Cisco CLI NOTE: Use the following CLI commands when the Cisco SN 5428 Management Inter face is not availabl e.
QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 93 V ERSION 1.0, M ARCH 2003 Cisco MDS 9000 Ser ies Switches Integration Checklist The followi ng steps must be complet ed to successfull y merge Cisco and QLogic fab rics. The remainder of th is section provides det ailed inst ructions and example s .
Cisco M DS 9000 Series S witche s Suppo rted Swit ches and Firmwa re Ve rsions P AGE 94 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Supported Switches and Firmware V ersions The followi ng QLogic switches have been tested in th e QLogic environment and comply with the FC-SW -2 standar d.
Cisco MDS 9000 S eries Swi tches Doma in I D Con figur ation QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 95 V ERSION 1.0, M ARCH 2003 3. From the Domain Manager dialog box, s elect the Configur ation tab. For the VSAN t o which you will connect the E-port, do the foll owing: a.
Cisco M DS 9000 Series S witche s Domain ID Co nfigurat ion P AGE 96 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 QLogic SANbox Manager GUI 1. S tart the SANbox Manager applicat ion. The SANbox Manager — Faceplate dial og box displays .
Cisco MDS 9000 S eries Swi tches Doma in I D Con figur ation QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 97 V ERSION 1.0, M ARCH 2003 For the QLogic SANbox2- 64, the following displays:.
Cisco M DS 9000 Series S witche s Domain ID Co nfigurat ion P AGE 98 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 3. From the Swi tch Properties — SANbox Manager dialog box, do the following : a. In the Doma in ID box, type a unique Domain ID for the switch .
Cisco MDS 9000 S eries Swi tches Doma in I D Con figur ation QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AG E 99 V ERSION 1.0, M ARCH 2003 Qlogic CLI NOTE: Use the CLI commands when the QLogi c SANbox Manag er GUI is not ava ilable. The procedures are t he same for the QLogic SANbox2-8, SANbox2-16, and SANbox2-64.
Cisco M DS 9000 Series S witche s Timeout Value s P AGE 10 0 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Ti meout V alues As per FC-SW -2 Fibre Channel standards, set a l .
Cisco MDS 9000 S eries Swi tches Timeout V alues QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 101 V ERSION 1.0, M ARCH 2003 3. From the T imers Policies dial og box, verify that R_A_T OV is set to 10000 and E_D_T OV is set to 2000 . I f th e settings are not correct , do the foll owing: a.
Cisco M DS 9000 Series S witche s Timeout Value s P AGE 10 2 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Cisco CLI login: admin Password: ****** ** Cisco_9216# show fctimer Use the above command to verify that R_A_TOV is set to 10000 and E_D_T OV is set to 2000.
Cisco MDS 9000 S eries Swi tches Timeout V alues QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 103 V ERSION 1.0, M ARCH 2003 QLogic SANbox Manager GUI A TTENTION!! The foll owing step s take the switch of fline; theref ore, do not perfor m them on a switch being managed in-band .
Cisco M DS 9000 Series S witche s Timeout Value s P AGE 10 4 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 For the QLogic SANbox2- 64, the following displays: 3. From the Switch Propert ies — SANbox Manager dialog box , veri fy that R_A_T OV is set to 10000 and E_D_TO V is set to 2000 .
Cisco MDS 9000 S eries Swi tches Timeout V alues QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 105 V ERSION 1.0, M ARCH 2003 For the QLogic SANbox2- 64, the following displays: 4. From the Switc h Properties — SANbox Manager dialog box Administrative St ate list, se lect offline .
Cisco M DS 9000 Series S witche s Timeout Value s P AGE 10 6 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 QLogic CLI NOTE: Use the CLI commands when the QLogi c SANbox Manag er GUI is not ava ilable. The procedures are t he same for the QLogic SANbox2-8, SANbox2-16, and SANbox2-64.
Cisco MDS 9000 S eries Swi tches Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 107 V ERSION 1.0, M ARCH 2003 Princi p al Sw itch Configur ation Cisco switches and QLogi c switches negot iate for pr incipal switch aut omaticall y .
Cisco M DS 9000 Series S witche s Zone Con figuratio n P AGE 10 8 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Cisco Fabri c Manager 1. S tart Cisco Fabric Manager . The Fabric Manager d ialog box displa ys. 2. From the F abric Manager dialog box lef t panel, do the following : a.
Cisco MDS 9000 S eries Swi tches Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 109 V ERSION 1.0, M ARCH 2003 QLogic SANbox Manager GUI 1. S tart the SANbox Manager applicat ion. The SANbox Manager — Faceplate dial og box displays .
Cisco M DS 9000 Series S witche s Zone Con figuratio n P AGE 11 0 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 For the QLogic SANbox2- 64, the following displays:.
Cisco MDS 9000 S eries Swi tches Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 111 V ERSION 1.0, M ARCH 2003 3. From the Edit Zoning — SANbox Manager dialog box, comp are the.
Cisco M DS 9000 Series S witche s Zone Con figuratio n P AGE 11 2 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 For the QLogic SANbox2- 64, the following displays: QLogic CLI NOTE: Use the CLI commands when the QLogi c SANbox Manag er GUI is not ava ilable.
Cisco MDS 9000 S eries Swi tches Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 113 V ERSION 1.0, M ARCH 2003 Zone T y pes All zone members must be specified by a w orld wide port name (WWPN) in orde r to comply with Fibre Channe l st andards.
Cisco M DS 9000 Series S witche s Zone Con figuratio n P AGE 11 4 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Cisco CLI NOTE: Use the following CLI commands when the Cisc o Fabric Manager is not availabl e.
Cisco MDS 9000 S eries Swi tches Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 115 V ERSION 1.0, M ARCH 2003 For the QLogic SANbox2- 64, the following displays:.
Cisco M DS 9000 Series S witche s Zone Con figuratio n P AGE 11 6 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 3. The Edit Zoning — SANbox Manager dialog box displays.
Cisco MDS 9000 S eries Swi tches Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 117 V ERSION 1.0, M ARCH 2003 For the QLogic SANbox2- 64, the following displays: QLogic CLI NOTE: Use the CLI commands when the QLogi c SANbox Manag er GUI is not ava ilable.
Cisco M DS 9000 Series S witche s Operating Mode Confi guration P AGE 11 8 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Operating Mod e Configur ation Not appli cable. Cisco S pecific C onfiguration Not appli cable. QLogic Specific Configuration Not appli cable.
QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 119 V ERSION 1.0, M ARCH 2003 Merging Q Logic and IB M BladeCente r Fabrics The followi ng QLogic switches have been tested in th e QLogic environment and comply with the FC-SW -2 standar d.
Merging QLog ic and IB M Blad eCenter Fab rics P AGE 12 0 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3.
QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 121 V ERSION 1.0, M ARCH 2003 IBM eServer Blade Center Fibr e Chann el Switch Mod ule Integration Checklist The foll owing ste ps must be completed to successfully merge IBM BladeCenter and QLogi c fabrics.
IBM eSer ver Blade Center Fibre Cha nnel Sw itch Mod ule Suppo rted Swit ches and Firmwa re Ve rsions P AGE 12 2 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Supported Switches and Firmware V ersions The followi ng QLogic switches have been tested in th e QLogic environment and comply with the FC-SW -2 standar d.
IBM eSer ver Blad eCenter Fi bre Channe l Switch Modul e Doma in I D Con figur ation QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 123 V ERSION 1.0, M ARCH 2003 Domain ID Configur ation T o ensure that there are no conflict s between switches, we re commend that each switc h have an assigned Domain ID.
IBM eSer ver Blade Center Fibre Cha nnel Sw itch Mod ule Domain ID Co nfigurat ion P AGE 12 4 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 3. From the Switch P rop ertie s — IBM B lade Cen ter SAN Util ity dialog box, do t he foll owing: a.
IBM eSer ver Blad eCenter Fi bre Channe l Switch Modul e Doma in I D Con figur ation QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 125 V ERSION 1.0, M ARCH 2003 IBM eServer BladeCenter Fib re C hannel Switch Module CLI NOTE: Use the CLI commands wh en the IBM eServer Blade Center SAN Utili ty is not avail able.
IBM eSer ver Blade Center Fibre Cha nnel Sw itch Mod ule Domain ID Co nfigurat ion P AGE 12 6 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 QLogic SANbox Manager GUI 1. S tart the SANbox Manager applicat ion. The SANbox Manager — Faceplate dial og box displays .
IBM eSer ver Blad eCenter Fi bre Channe l Switch Modul e Doma in I D Con figur ation QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 127 V ERSION 1.0, M ARCH 2003 For the QLogic SANbox2- 64, the fol.
IBM eSer ver Blade Center Fibre Cha nnel Sw itch Mod ule Domain ID Co nfigurat ion P AGE 12 8 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 3. From the Swi tch Properties — SANbox Manager dialog box, do the following : a. In the Doma in ID box, type a unique Domain ID for the switch .
IBM eSer ver Blad eCenter Fi bre Channe l Switch Modul e Doma in I D Con figur ation QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 129 V ERSION 1.0, M ARCH 2003 Qlogic CLI NOTE: Use the CLI commands when the QLogi c SANbox Manag er GUI is not ava ilable.
IBM eSer ver Blade Center Fibre Cha nnel Sw itch Mod ule Timeout Value s P AGE 13 0 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Ti meout V alues As per FC-SW -2 Fibre Chan.
IBM eSer ver Blad eCenter Fi bre Channe l Switch Modul e Timeout V alues QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 131 V ERSION 1.0, M ARCH 2003 3. From the Swit ch Pro pert ies — IBM B lade Cente r SA N Utili ty dialog box, ver ify that R_ A_TO V is se t to 10000 and E_D_TOV is se t to 2000 .
IBM eSer ver Blade Center Fibre Cha nnel Sw itch Mod ule Timeout Value s P AGE 13 2 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 IBM eServer BladeCenter Fib re C hannel Switch Module CLI NOTE: Use the CLI commands wh en the IBM eServer Blade Center SAN Utili ty is not avail able.
IBM eSer ver Blad eCenter Fi bre Channe l Switch Modul e Timeout V alues QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 133 V ERSION 1.0, M ARCH 2003 QLogic SANbox Manager GUI A TTENTION!! The foll owing step s take the switch of fline; theref ore, do not perfor m them on a switch being managed in-band .
IBM eSer ver Blade Center Fibre Cha nnel Sw itch Mod ule Timeout Value s P AGE 13 4 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 For the QLogic SANbox2- 64, the following displays: 3. From the Switch Propert ies — SANbox Manager dialog box , veri fy that R_A_T OV is set to 10000 and E_D_TO V is set to 2000 .
IBM eSer ver Blad eCenter Fi bre Channe l Switch Modul e Timeout V alues QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 135 V ERSION 1.0, M ARCH 2003 For the QLogic SANbox2- 64, the following displays: 4. From the Switc h Properties — SANbox Manager dialog box Administrative St ate list, se lect offline .
IBM eSer ver Blade Center Fibre Cha nnel Sw itch Mod ule Princ ipal S witch Configu ratio n P AGE 13 6 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 QLogic CLI NOTE: Use the CLI commands when the QLogi c SANbox Manag er GUI is not ava ilable.
IBM eSer ver Blad eCenter Fi bre Channe l Switch Modul e Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 137 V ERSION 1.0, M ARCH 2003 Zone Configuration This section disc usses configuri ng active Zone Set names and Zone types. Active Zone Set Names The Zone and Zone Set n am es on each switch must be un ique.
IBM eSer ver Blade Center Fibre Cha nnel Sw itch Mod ule Zone Con figuratio n P AGE 13 8 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 3.
IBM eSer ver Blad eCenter Fi bre Channe l Switch Modul e Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 139 V ERSION 1.0, M ARCH 2003 QLogic SANbox Manager GUI 1. S tart the SANbox Manager applicat ion. The SANbox Manager — Faceplate dial og box displays .
IBM eSer ver Blade Center Fibre Cha nnel Sw itch Mod ule Zone Con figuratio n P AGE 14 0 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 For the QLogic SANbox2- 64, the follow.
IBM eSer ver Blad eCenter Fi bre Channe l Switch Modul e Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 141 V ERSION 1.0, M ARCH 2003 3.
IBM eSer ver Blade Center Fibre Cha nnel Sw itch Mod ule Zone Con figuratio n P AGE 14 2 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 For the QLogic SANbox2- 64, the following displays: QLogic CLI NOTE: Use the CLI commands when the QLogi c SANbox Manag er GUI is not ava ilable.
IBM eSer ver Blad eCenter Fi bre Channe l Switch Modul e Opera ting M ode Configu ratio n QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 143 V ERSION 1.0, M ARCH 2003 Operating Mod e Configur ation NOTE: Perform the following st eps only when connect ing from a QLogic SANbox2-8 or SANbox2-16 wit h vers ion 1.
IBM eSer ver Blade Center Fibre Cha nnel Sw itch Mod ule IBM Blad eCenter S pecific Config uration P AGE 14 4 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 3. The Zoning Config — SANbox Manager dialog box display s. In the Merg e Mod e list, sel ect Merge Acti ve Zoneset s O nly .
IBM eSer ver Blad eCenter Fi bre Channe l Switch Modul e Succes sful I ntegratio n Chec klist QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 145 V ERSION 1.0, M ARCH 2003 Successful I ntegration Checkl ist Perform the follo wing steps af ter the E-port connection has been est ablished and the fabric has had time to update.
IBM eSer ver Blade Center Fibre Cha nnel Sw itch Mod ule Succes sful Integr ation Checkl ist P AGE 14 6 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.
QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 147 V ERSION 1.0, M ARCH 2003 Merging QL ogic a nd INRANGE Fabrics The followi ng QLogic switches have been tested in th e QLogic environment and comply with the FC-SW -2 st andard.
Merging QLogic and INRANG E Fabric s P AGE 14 8 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3.
QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 149 V ERSION 1.0, M ARCH 2003 INRANGE FC/9000 Switch Integration Checklist The foll owing step s must be complete d to successf ully merge INRANGE and QLogic fabr ics. The remainder of th is section provides det ailed inst ructions and example s .
INRANGE FC/900 0 Switch Conf igurat ion Limita tio ns P AGE 15 0 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Configuration Lim it ations When merging INRANGE and QLogic fabrics, the maximu m number of switches that can be configur ed depends upon the INRANGE switch configurati on.
INRAN GE FC/9000 Switch Doma in I D Con figur ation QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 151 V ERSION 1.0, M ARCH 2003 INRANGE IN-VSN Enterprise Manager 1. S tart the INRANGE IN-VSN Enterprise Manager . The IN-V NS En terpr ise M ana ger dialog box displays .
INRANGE FC/900 0 Switch Domain ID Co nfigurat ion P AGE 15 2 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 QLogic SANbox Manager GUI 1. S tart the SANbox Manager applicat ion. The SANbox Manager — Faceplate dial og box displays .
INRAN GE FC/9000 Switch Doma in I D Con figur ation QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 153 V ERSION 1.0, M ARCH 2003 For the QLogic SANbox2- 64, the following displays:.
INRANGE FC/900 0 Switch Domain ID Co nfigurat ion P AGE 15 4 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 3. From the Swi tch Properties — SANbox Manager dialog box, do the following : a. In the Doma in ID box, type a unique Domain ID for the switch .
INRAN GE FC/9000 Switch Timeout V alues QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 155 V ERSION 1.0, M ARCH 2003 Qlogic CLI NOTE: Use the CLI commands when the QLogi c SANbox Manag er GUI is not ava ilable. The procedures are t he same for the QLogic SANbox2-8, SANbox2-16, and SANbox2-64.
INRANGE FC/900 0 Switch Timeout Value s P AGE 15 6 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 INRANGE IN-VSN Enterprise Manager 1. S tart the INRANGE IN-VSN Enterprise Manager . The IN-V NS En terpr ise M ana ger dialog box displays .
INRAN GE FC/9000 Switch Timeout V alues QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 157 V ERSION 1.0, M ARCH 2003 QLogic SANbox Manager GUI A TTENTION!! The foll owing step s take the switch of fline; theref ore, do not perfor m them on a switch being managed in-band .
INRANGE FC/900 0 Switch Timeout Value s P AGE 15 8 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 For the QLogic SANbox2- 64, the following displays: 3. From the Switch Propert ies — SANbox Manager dialog box , veri fy that R_A_T OV is set to 10000 and E_D_TO V is set to 2000 .
INRAN GE FC/9000 Switch Timeout V alues QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 159 V ERSION 1.0, M ARCH 2003 For the QLogic SANbox2- 64, the following displays: 4. From the Switc h Properties — SANbox Manager dialog box Administrative St ate list, se lect offline .
INRANGE FC/900 0 Switch Princ ipal S witch Configu ratio n P AGE 16 0 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 QLogic CLI NOTE: Use the CLI commands when the QLogi c SANbox Manag er GUI is not ava ilable. The procedures are t he same for the QLogic SANbox2-8, SANbox2-16, and SANbox2-64.
INRAN GE FC/9000 Switch Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 161 V ERSION 1.0, M ARCH 2003 Zone Configuration This section disc usses configuri ng active Zone Set names and Zone types. Active Zone Set Names The Zone and Zone Set n am es on each switch must be un ique.
INRANGE FC/900 0 Switch Zone Con figuratio n P AGE 16 2 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 INRANGE IN-VSN Enterprise Manager 1. S tart the INRANGE IN-VSN Enterprise Manager . The IN-V NS En terpr ise M ana ger dialog box displays .
INRAN GE FC/9000 Switch Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 163 V ERSION 1.0, M ARCH 2003 2. From the E- Port Zoning (All Fabri cs) dialog b ox, sel ect the fabric an d click the Zoom In button.
INRANGE FC/900 0 Switch Zone Con figuratio n P AGE 16 4 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 3. From the E- Port Zoning (Fabric x : All Director Domains) dialog box, selec t the director and click the Zoom In button.
INRAN GE FC/9000 Switch Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 165 V ERSION 1.0, M ARCH 2003 4. From the E-Port Zo ning (Fabric x : Direct or y : All Zoneset s) dialog box, sel ect th e Zonesets tab.
INRANGE FC/900 0 Switch Zone Con figuratio n P AGE 16 6 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 5. Select the Al l Zones tab. V erify that all Zone names confor m to the st andards for zon e naming as discus sed under “Active Zone Set Names” on p age 161 .
INRAN GE FC/9000 Switch Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 167 V ERSION 1.0, M ARCH 2003 QLogic SANbox Manager GUI 1. S tart the SANbox Manager applicat ion. The SANbox Manager — Faceplate dial og box displays . 2.
INRANGE FC/900 0 Switch Zone Con figuratio n P AGE 16 8 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 For the QLogic SANbox2- 64, the following displays:.
INRAN GE FC/9000 Switch Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 169 V ERSION 1.0, M ARCH 2003 3. From the Edit Zoning — SANbox Manager dialog box, comp are the Zone Set.
INRANGE FC/900 0 Switch Zone Con figuratio n P AGE 17 0 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 For the QLogic SANbox2- 64, the following displays: QLogic CLI NOTE: Use the CLI commands when the QLogi c SANbox Manag er GUI is not ava ilable.
INRAN GE FC/9000 Switch Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 171 V ERSION 1.0, M ARCH 2003 Zone T y pes All zone members must be specified by a w orld wide port name (WWPN) in orde r to comply with Fibre Channe l st andards.
INRANGE FC/900 0 Switch Zone Con figuratio n P AGE 17 2 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 2. From the E- Port Zoning (All Fabri cs) dialog b ox, sel ect the fabric an d click the Zoom In button.
INRAN GE FC/9000 Switch Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 173 V ERSION 1.0, M ARCH 2003 3. From the E- Port Zoning (Fabric x : All Director Domains) dialog box, selec t the director and click the Zoom In button.
INRANGE FC/900 0 Switch Zone Con figuratio n P AGE 17 4 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 4. From the E-Port Zoning (Fabric x : Director y : All Zones) di alog box, sel ect the Al l Zones tab. V erify th at all Zone Member T ypes a re s et to Port WWN .
INRAN GE FC/9000 Switch Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 175 V ERSION 1.0, M ARCH 2003 QLogic SANbox Manager GUI 1. S tart the SANbox Manager applicat ion. The SANbox Manager — Faceplate dial og box displays . 2.
INRANGE FC/900 0 Switch Zone Con figuratio n P AGE 17 6 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 For the QLogic SANbox2- 64, the following displays:.
INRAN GE FC/9000 Switch Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 177 V ERSION 1.0, M ARCH 2003 3. The Edit Zoning — SANbox Manager dialog box displays.
INRANGE FC/900 0 Switch Operating Mode Confi guration P AGE 17 8 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 For the QLogic SANbox2- 64, the following displays: QLogic CLI NOTE: Use the CLI commands when the QLogi c SANbox Manag er GUI is not ava ilable.
INRAN GE FC/9000 Switch Succes sful I ntegratio n Chec klist QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 179 V ERSION 1.0, M ARCH 2003 QLogic Specific Configuration Not appli cable. Successful I ntegration Checkl ist Perform the follo wing steps af ter the E-port connection has been est ablished and the fabric has had time to update.
INRANGE FC/900 0 Switch Succes sful Integr ation Checkl ist P AGE 18 0 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3.
QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 181 V ERSION 1.0, M ARCH 2003 Merg ing QL ogic and McDA T A Fabr ics The followi ng QLogic switches have been tested in th e QLogic environment and comply with the FC-SW -2 st andard.
Merging QLogic and McDA TA Fabric s P AGE 18 2 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3.
QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 183 V ERSION 1.0, M ARCH 2003 McDA T A S phereon 4500 Switch Integration Checklist The followi ng steps must be complet ed to successfull y merge McDA T A and QLogic fabrics. The remainder of th is section provides det ailed inst ructions and example s .
McDATA S phereon 4 500 Switc h Suppo rted Swit ches and Firmwa re Ve rsions P AGE 18 4 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Supported Switches and Firmware V ersions The followi ng QLogic switches have been tested in th e QLogic environment and comply with the FC-SW -2 st andard.
McDATA Sp hereon 4 500 Swi tch Doma in I D Con figur ation QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 185 V ERSION 1.0, M ARCH 2003 McDA T A Sphereon W eb Management 1. S tart McDA T A S phereon W eb Management. The Main S witc h View dialog box displays.
McDATA S phereon 4 500 Switc h Domain ID Co nfigurat ion P AGE 18 6 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 3. On the navigatio n panel, select Configur e . The Configure dialog box di splays. Select the Switch t ab, select the Parameters tab, and do the fol lowing: a.
McDATA Sp hereon 4 500 Swi tch Doma in I D Con figur ation QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 187 V ERSION 1.0, M ARCH 2003 4. On the navigation p anel, select Operations . The Operati ons dialog box displays. Sele ct the Switch t ab, select the Online St ate tab, then cli ck the Set Online button.
McDATA S phereon 4 500 Switc h Domain ID Co nfigurat ion P AGE 18 8 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 QLogic SANbox Manager GUI 1. S tart the SANbox Manager applicat ion. The SANbox Manager — Faceplate dial og box displays .
McDATA Sp hereon 4 500 Swi tch Doma in I D Con figur ation QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 189 V ERSION 1.0, M ARCH 2003 For the QLogic SANbox2- 64, the following displays:.
McDATA S phereon 4 500 Switc h Domain ID Co nfigurat ion P AGE 19 0 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 3. From the Swi tch Properties — SANbox Manager dialog box, do the following : a. In the Doma in ID box, type a unique Domain ID for the switch .
McDATA Sp hereon 4 500 Swi tch Doma in I D Con figur ation QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 191 V ERSION 1.0, M ARCH 2003 Qlogic CLI NOTE: Use the CLI commands when the QLogi c SANbox Manag er GUI is not ava ilable. The procedures are t he same for the QLogic SANbox2-8, SANbox2-16, and SANbox2-64.
McDATA S phereon 4 500 Switc h Timeout Value s P AGE 19 2 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Ti meout V alues As per FC-SW -2 Fibre Channel standards, set a l l s.
McDATA Sp hereon 4 500 Swi tch Timeout V alues QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 193 V ERSION 1.0, M ARCH 2003 3. On the navigation p anel, select Operations . The Operati ons dialog box displays. Sele ct the Switch t ab, select O nlin e State tab, then click the Set Of fline button.
McDATA S phereon 4 500 Switc h Timeout Value s P AGE 19 4 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 4. On the navigatio n panel, select Configur e , The Configure di alog box displays. Select the Switch t ab, select the Fa bric Para mete rs tab, then do the following: a.
McDATA Sp hereon 4 500 Swi tch Timeout V alues QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 195 V ERSION 1.0, M ARCH 2003 5. On the navigation p anel, select Operations . The Operati ons dialog box displays. Sele ct the Switch t ab, select the Online St ate tab, then cli ck the Set Online button.
McDATA S phereon 4 500 Switc h Timeout Value s P AGE 19 6 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 McDA T A T elnet C LI NOTE: Use the f ollowing CLI commands wh en McDA T A S phereon Web Management is not availabl e.
McDATA Sp hereon 4 500 Swi tch Timeout V alues QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 197 V ERSION 1.0, M ARCH 2003 QLogic SANbox Manager GUI A TTENTION!! The foll owing step s take the switch of fline; theref ore, do not perfor m them on a switch being managed in-band .
McDATA S phereon 4 500 Switc h Timeout Value s P AGE 19 8 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 For the QLogic SANbox2- 64, the following displays: 3. From the Switch Propert ies — SANbox Manager dialog box , veri fy that R_A_T OV is set to 10000 and E_D_TO V is set to 2000 .
McDATA Sp hereon 4 500 Swi tch Timeout V alues QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 199 V ERSION 1.0, M ARCH 2003 For the QLogic SANbox2- 64, the following displays: 4. From the Switc h Properties — SANbox Manager dialog box Administrative St ate list, se lect offline .
McDATA S phereon 4 500 Switc h Princ ipal S witch Configu ratio n P AGE 20 0 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 QLogic CLI NOTE: Use the CLI commands when the QLogi c SANbox Manag er GUI is not ava ilable. The procedures are t he same for the QLogic SANbox2-8, SANbox2-16, and SANbox2-64.
McDATA Sp hereon 4 500 Swi tch Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 201 V ERSION 1.0, M ARCH 2003 Zone Configuration This section disc usses configuri ng active Zone Set names and Zone types. Active Zone Set Names The Zone and Zone Set n am es on each switch must be un ique.
McDATA S phereon 4 500 Switc h Zone Con figuratio n P AGE 20 2 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 McDA T A Sphereon W eb Management 1. S tart McDA T A S phereon W eb Management. The Main S witc h View dialog box displays.
McDATA Sp hereon 4 500 Swi tch Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 203 V ERSION 1.0, M ARCH 2003 3. On the navigatio n panel, select Configur e . The Configure di alog box displays. Select the Zoning tab , then select the Zones t ab.
McDATA S phereon 4 500 Switc h Zone Con figuratio n P AGE 20 4 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 QLogic SANbox Manager GUI 1. S tart the SANbox Manager applicat ion. The SANbox Manager — Faceplate dial og box displays .
McDATA Sp hereon 4 500 Swi tch Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 205 V ERSION 1.0, M ARCH 2003 For the QLogic SANbox2- 64, the following displays:.
McDATA S phereon 4 500 Switc h Zone Con figuratio n P AGE 20 6 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 3. From the Edit Zoning — SANbox Manager dialog box, comp are .
McDATA Sp hereon 4 500 Swi tch Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 207 V ERSION 1.0, M ARCH 2003 For the QLogic SANbox2- 64, the following displays: QLogic CLI NOTE: Use the CLI commands when the QLogi c SANbox Manag er GUI is not ava ilable.
McDATA S phereon 4 500 Switc h Zone Con figuratio n P AGE 20 8 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Zone T y pes All zone members must be specified by a w orld wide port name (WWPN) in orde r to comply with Fibre Channe l st andards.
McDATA Sp hereon 4 500 Swi tch Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 209 V ERSION 1.0, M ARCH 2003 3. Select ea ch zone a nd veri fy that all members are sp ecified by WWN. McDA T A T elnet C LI NOTE: Use the f ollowing CLI commands wh en McDA T A S phereon Web Management is not availabl e.
McDATA S phereon 4 500 Switc h Zone Con figuratio n P AGE 21 0 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 QLogic SANbox Manager GUI 1. S tart the SANbox Manager applicat ion. The SANbox Manager — Faceplate dial og box displays .
McDATA Sp hereon 4 500 Swi tch Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 211 V ERSION 1.0, M ARCH 2003 For the QLogic SANbox2- 64, the following displays:.
McDATA S phereon 4 500 Switc h Zone Con figuratio n P AGE 21 2 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 3. The Edit Zoning — SANbox Manager dialog box displays.
McDATA Sp hereon 4 500 Swi tch Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 213 V ERSION 1.0, M ARCH 2003 For the QLogic SANbox2- 64, the following displays: QLogic CLI NOTE: Use the CLI commands when the QLogi c SANbox Manag er GUI is not ava ilable.
McDATA S phereon 4 500 Switc h Operating Mode Confi guration P AGE 21 4 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Operating Mod e Configur ation McDA T A Sphereon W eb Management 1. S tart McDA T A S phereon W eb Management.
McDATA Sp hereon 4 500 Swi tch Opera ting M ode Configu ratio n QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 215 V ERSION 1.0, M ARCH 2003 3. On the navigatio n panel, select Configur e . The Configure di alog box displays. Select the Zoning tab, se lect the Zone Set tab, then the Disable Defa ult Zone button.
McDATA S phereon 4 500 Switc h Operating Mode Confi guration P AGE 21 6 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 4. On the navigatio n panel, select Configur e . The Configure di alog box displays. Select the Switch t ab, select the Fa bric Para mete rs tab, then do the following: a.
McDATA Sp hereon 4 500 Swi tch Opera ting M ode Configu ratio n QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 217 V ERSION 1.0, M ARCH 2003 5. On the navigation p anel, select Operations . The Operati ons dialog box displays. Sele ct the Switch t ab, select O nlin e State tab, then click the Set Onli ne button.
McDATA S phereon 4 500 Switc h McDATA S pecif ic Config uration P AGE 21 8 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 McDA T A T elnet C LI NOTE: Use the f ollowing CLI commands wh en McDA T A S phereon Web Management is not availabl e.
McDATA Sp hereon 4 500 Swi tch Succes sful I ntegratio n Chec klist QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 219 V ERSION 1.0, M ARCH 2003 Successful I ntegration Checkl ist Perform the follo wing steps af ter the E-port connection has been est ablished and the fabric has had time to update.
McDATA S phereon 4 500 Switc h Succes sful Integr ation Checkl ist P AGE 22 0 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3.
QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 221 V ERSION 1.0, M ARCH 2003 McDA T A Intre pid 6000 Series Director s Integration Checklist The followi ng steps must be complet ed to successfull y merge McDA T A and QLogic fabrics. The remainder of th is section provides det ailed inst ructions and example s .
McDATA In trepid 60 00 Seri es Director s Suppo rted Swit ches and Firmwa re Ve rsions P AGE 22 2 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Supported Switches and Firmware V ersions The followi ng QLogic switches have been tested in th e QLogic environment and comply with the FC-SW -2 standar d.
McDATA In trepid 60 00 Series Directo rs Doma in I D Con figur ation QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 223 V ERSION 1.0, M ARCH 2003 McDA T A SANpilot Web Management 1. S tart McDA T A SANpilot W eb Management. The Main Dir ector V iew dialo g box displ ays.
McDATA In trepid 60 00 Seri es Director s Domain ID Co nfigurat ion P AGE 22 4 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 3. On the navigatio n panel, select Configur e . The Configure dialog box di splays. Select the Director t ab, select the Param eter s tab, and do the fol lowing: a.
McDATA In trepid 60 00 Series Directo rs Doma in I D Con figur ation QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 225 V ERSION 1.0, M ARCH 2003 4. On the navigation p anel, select Operations . The Operati ons dialog box displays. Sele ct the Director t ab, select the Onlin e St ate tab, then cli ck the Set Online button.
McDATA In trepid 60 00 Seri es Director s Domain ID Co nfigurat ion P AGE 22 6 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 McDA T A T elnet C LI NOTE: Use the following CLI commands when McDA T A SANpilot W eb M anagement is not availabl e.
McDATA In trepid 60 00 Series Directo rs Doma in I D Con figur ation QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 227 V ERSION 1.0, M ARCH 2003 QLogic SANbox Manager GUI 1. S tart the SANbox Manager applicat ion. The SANbox Manager — Faceplate dial og box displays .
McDATA In trepid 60 00 Seri es Director s Domain ID Co nfigurat ion P AGE 22 8 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 For the QLogic SANbox2- 64, the following displa.
McDATA In trepid 60 00 Series Directo rs Doma in I D Con figur ation QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 229 V ERSION 1.0, M ARCH 2003 3. From the Swi tch Properties — SANbox Manager dialog box, do the following : a. In the Doma in ID box, type a unique Domain ID for the switch .
McDATA In trepid 60 00 Seri es Director s Domain ID Co nfigurat ion P AGE 23 0 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Qlogic CLI NOTE: Use the CLI commands when the QLogi c SANbox Manag er GUI is not ava ilable. The procedures are t he same for the QLogic SANbox2-8, SANbox2-16, and SANbox2-64.
McDATA In trepid 60 00 Series Directo rs Timeout V alues QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 231 V ERSION 1.0, M ARCH 2003 Ti meout V alues As per FC-SW -2 Fibre Channel standards, set a.
McDATA In trepid 60 00 Seri es Director s Timeout Value s P AGE 23 2 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 3. On the navigation p anel, select Operations . The Operati ons dialog box displays. Sele ct the Director t ab, select O nlin e State tab, then cli ck the Set Of fline button.
McDATA In trepid 60 00 Series Directo rs Timeout V alues QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 233 V ERSION 1.0, M ARCH 2003 4. On the navigatio n panel, select Configur e , The Configure di alog box displays. Select the Director t ab, select the Fabric Parameters tab, then do the fol lowing : a.
McDATA In trepid 60 00 Seri es Director s Timeout Value s P AGE 23 4 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 5. On the navigation p anel, select Operations . The Operati ons dialog box displays. Sele ct the Director t ab, select the Onlin e St ate tab, then cli ck the Set Online button.
McDATA In trepid 60 00 Series Directo rs Timeout V alues QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 235 V ERSION 1.0, M ARCH 2003 McDA T A T elnet C LI NOTE: Use the following CLI commands when McDA T A SANpilot W eb M anagement is not availabl e.
McDATA In trepid 60 00 Seri es Director s Timeout Value s P AGE 23 6 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 QLogic SANbox Manager GUI A TTENTION!! The foll owing step s take the switch of fline; theref ore, do not perfor m them on a switch being managed in-band .
McDATA In trepid 60 00 Series Directo rs Timeout V alues QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 237 V ERSION 1.0, M ARCH 2003 For the QLogic SANbox2- 64, the following displays: 3. From the Switch Propert ies — SANbox Manager dialog box , veri fy that R_A_T OV is set to 10000 and E_D_TO V is set to 2000 .
McDATA In trepid 60 00 Seri es Director s Timeout Value s P AGE 23 8 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 For the QLogic SANbox2- 64, the following displays: 4. From the Switc h Properties — SANbox Manager dialog box Administrative St ate list, se lect offline .
McDATA In trepid 60 00 Series Directo rs Princi pal S witch Configu ratio n QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 239 V ERSION 1.0, M ARCH 2003 QLogic CLI NOTE: Use the CLI commands when the QLogi c SANbox Manag er GUI is not ava ilable. The procedures are t he same for the QLogic SANbox2-8, SANbox2-16, and SANbox2-64.
McDATA In trepid 60 00 Seri es Director s Zone Con figuratio n P AGE 24 0 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Zone Configuration This section disc usses configuri ng active Zone Set names and Zone types. Active Zone Set Names The Zone and Zone Set n am es on each switch must be un ique.
McDATA In trepid 60 00 Series Directo rs Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 241 V ERSION 1.0, M ARCH 2003 McDA T A SANpilot Web Management 1. S tart McDA T A SANpilot W eb Management. The Main Dir ector V iew dialo g box displ ays.
McDATA In trepid 60 00 Seri es Director s Zone Con figuratio n P AGE 24 2 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 3. On the navigatio n panel, select Configur e . The Configure di alog box displays. Select the Zoning tab , then select the Zones t ab.
McDATA In trepid 60 00 Series Directo rs Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 243 V ERSION 1.0, M ARCH 2003 QLogic SANbox Manager GUI 1. S tart the SANbox Manager applicat ion. The SANbox Manager — Faceplate dial og box displays .
McDATA In trepid 60 00 Seri es Director s Zone Con figuratio n P AGE 24 4 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 For the QLogic SANbox2- 64, the following displays:.
McDATA In trepid 60 00 Series Directo rs Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 245 V ERSION 1.0, M ARCH 2003 3. From the Edit Zoning — SANbox Manager dialog box, comp.
McDATA In trepid 60 00 Seri es Director s Zone Con figuratio n P AGE 24 6 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 For the QLogic SANbox2- 64, the following displays: QLogic CLI NOTE: Use the CLI commands when the QLogi c SANbox Manag er GUI is not ava ilable.
McDATA In trepid 60 00 Series Directo rs Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 247 V ERSION 1.0, M ARCH 2003 Zone T y pes All zone members must be specified by a w orld wide port name (WWPN) in orde r to comply with Fibre Channe l st andards.
McDATA In trepid 60 00 Seri es Director s Zone Con figuratio n P AGE 24 8 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 3. For each t he zone selected i n ste p 2 , v erify t hat all members are s pecified by WWN.
McDATA In trepid 60 00 Series Directo rs Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 249 V ERSION 1.0, M ARCH 2003 McDA T A T elnet C LI NOTE: NOTE: Use the followin g CLI commands when McDA T A SANpilot Web Management is not avai lable.
McDATA In trepid 60 00 Seri es Director s Zone Con figuratio n P AGE 25 0 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 QLogic SANbox Manager GUI 1. S tart the SANbox Manager applicat ion. The SANbox Manager — Faceplate dial og box displays .
McDATA In trepid 60 00 Series Directo rs Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 251 V ERSION 1.0, M ARCH 2003 For the QLogic SANbox2- 64, the following displays:.
McDATA In trepid 60 00 Seri es Director s Zone Con figuratio n P AGE 25 2 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 3. The Edit Zoning — SANbox Manager dialog box displays. Conf irm that all zone memb ers are list ed as WWN.
McDATA In trepid 60 00 Series Directo rs Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 253 V ERSION 1.0, M ARCH 2003 For the QLogic SANbox2- 64, the following displays: QLogic CLI NOTE: Use the CLI commands when the QLogi c SANbox Manag er GUI is not ava ilable.
McDATA In trepid 60 00 Seri es Director s Operating Mode Confi guration P AGE 25 4 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Operating Mod e Configur ation McDA T A SANpilot Web Management 1. S tart McDA T A SANpilot W eb Management.
McDATA In trepid 60 00 Series Directo rs Opera ting M ode Configu ratio n QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 255 V ERSION 1.0, M ARCH 2003 3. On the navigatio n panel, select Configur e . The Configure di alog box displays. Select the Zoning tab, se lect the Zone Set tab, then the Disable Defa ult Zone button.
McDATA In trepid 60 00 Seri es Director s Operating Mode Confi guration P AGE 25 6 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 4. On the navigatio n panel, select Configur e . The Configure di alog box displays. Select the Director t ab, select the Fabric Parameters tab, then do the following : a.
McDATA In trepid 60 00 Series Directo rs Opera ting M ode Configu ratio n QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 257 V ERSION 1.0, M ARCH 2003 5. On the navigation p anel, select Operations . The Operati ons dialog box displays. Sele ct the Director t ab, select the Onlin e St ate tab, then cli ck the Set Online button.
McDATA In trepid 60 00 Seri es Director s McDATA S pecif ic Config uration P AGE 25 8 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 McDA T A T elnet C LI NOTE: Use the f ollowing CLI commands wh en McDA T A S phereon Web Management is not availabl e.
McDATA In trepid 60 00 Series Directo rs Succes sful I ntegratio n Chec klist QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 259 V ERSION 1.0, M ARCH 2003 Successful I ntegration Checkl ist Perform the follo wing steps af ter the E-port connection has been est ablished and the fabric has had time to update.
McDATA In trepid 60 00 Seri es Director s Succes sful Integr ation Checkl ist P AGE 26 0 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3.
QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 261 V ERSION 1.0, M ARCH 2003 Merging QLog ic and Sun Fa brics The followi ng QLogic switches have been tested in th e QLogic environment and comply with the FC-SW -2 standar d. QLogic switches have tested interope rable with the foll owing switches fr om Sun that comply with the FC- SW-2 standa rd.
Merging QLogic and Su n Fabric s P AGE 26 2 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3.
QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 263 V ERSION 1.0, M ARCH 2003 Sun StorEdge Networ k 2 Gb FC Ser ies Switch es Integration Checklist The followi ng steps must be complet ed to successfull y merge Sun and QLogic fabrics. The remainder of th is section provides det ailed inst ructions and example s .
Sun St orEdge N etwork 2 Gb FC S eries S witche s Suppo rted Swit ches and Firmwa re Ve rsions P AGE 26 4 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Supported Switches and Firmware V ersions The followi ng QLogic switches have been tested in th e QLogic environment and comply with the FC-SW -2 standar d.
Sun Sto rEdge Net work 2 G b FC Ser ies Switc hes Doma in I D Con figur ation QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 265 V ERSION 1.0, M ARCH 2003 Domain ID Configur ation T o ensure that there are no conflict s between switches, we re commend that each switc h have an assigned Domai n ID.
Sun St orEdge N etwork 2 Gb FC S eries S witche s Domain ID Co nfigurat ion P AGE 26 6 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 3. From the Swi tch Properties — SANbox Manager dialog box, do the following : a. In the Doma in ID box, type a unique Domain ID for the switch .
Sun Sto rEdge Net work 2 G b FC Ser ies Switc hes Doma in I D Con figur ation QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 267 V ERSION 1.0, M ARCH 2003 Sun StorEdge CLI NOTE: Use the CLI co m mands when the Sun S torEdge SANbox Manager GUI is not avai lable.
Sun St orEdge N etwork 2 Gb FC S eries S witche s Domain ID Co nfigurat ion P AGE 26 8 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 QLogic SANbox Manager GUI 1. S tart the SANbox Manager applicat ion. The SANbox Manager — Faceplate dial og box displays .
Sun Sto rEdge Net work 2 G b FC Ser ies Switc hes Doma in I D Con figur ation QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 269 V ERSION 1.0, M ARCH 2003 For the QLogic SANbox2- 64, the following .
Sun St orEdge N etwork 2 Gb FC S eries S witche s Domain ID Co nfigurat ion P AGE 27 0 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 3. From the Swi tch Properties — SANbox Manager dialog box, do the following : a. In the Doma in ID box, type a unique Domain ID for the switch .
Sun Sto rEdge Net work 2 G b FC Ser ies Switc hes Doma in I D Con figur ation QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 271 V ERSION 1.0, M ARCH 2003 Qlogic CLI NOTE: Use the CLI commands when the QLogi c SANbox Manag er GUI is not ava ilable.
Sun St orEdge N etwork 2 Gb FC S eries S witche s Timeout Value s P AGE 27 2 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Ti meout V alues As per FC-SW -2 Fibre Channel sta.
Sun Sto rEdge Net work 2 G b FC Ser ies Switc hes Timeout V alues QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 273 V ERSION 1.0, M ARCH 2003 3. From the Switch Propert ies — SANbox Manager dialog box , veri fy that R_A_T OV is set to 10000 and E_D_TO V is set to 2000 .
Sun St orEdge N etwork 2 Gb FC S eries S witche s Timeout Value s P AGE 27 4 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Sun StorEdge CLI NOTE: Use the CLI co m mands when the Sun S torEdge SANbox Manager GUI is not avai lable.
Sun Sto rEdge Net work 2 G b FC Ser ies Switc hes Timeout V alues QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 275 V ERSION 1.0, M ARCH 2003 QLogic SANbox Manager GUI A TTENTION!! The foll owing step s take the switch of fline; theref ore, do not perfor m them on a switch being managed in-band .
Sun St orEdge N etwork 2 Gb FC S eries S witche s Timeout Value s P AGE 27 6 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 For the QLogic SANbox2- 64, the following displays: 3. From the Switch Propert ies — SANbox Manager dialog box , veri fy that R_A_T OV is set to 10000 and E_D_TO V is set to 2000 .
Sun Sto rEdge Net work 2 G b FC Ser ies Switc hes Timeout V alues QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 277 V ERSION 1.0, M ARCH 2003 For the QLogic SANbox2- 64, the following displays: 4. From the Switc h Properties — SANbox Manager dialog box Administrative St ate list, se lect offline .
Sun St orEdge N etwork 2 Gb FC S eries S witche s Princ ipal S witch Configu ratio n P AGE 27 8 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 QLogic CLI NOTE: Use the CLI commands when the QLogi c SANbox Manag er GUI is not ava ilable.
Sun Sto rEdge Net work 2 G b FC Ser ies Switc hes Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 279 V ERSION 1.0, M ARCH 2003 Zone Configuration This section disc usses configuri ng active Zone Set names and Zone types. Active Zone Set Names The Zone and Zone Set n am es on each switch must be un ique.
Sun St orEdge N etwork 2 Gb FC S eries S witche s Zone Con figuratio n P AGE 28 0 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Sun StorEdge SANbox Manager GUI 1. S tart the SANbox Manager applicat ion. The SANbox Manager — Faceplate dial og box displays .
Sun Sto rEdge Net work 2 G b FC Ser ies Switc hes Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 281 V ERSION 1.0, M ARCH 2003 3.
Sun St orEdge N etwork 2 Gb FC S eries S witche s Zone Con figuratio n P AGE 28 2 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 QLogic SANbox Manager GUI 1. S tart the SANbox Manager applicat ion. The SANbox Manager — Faceplate dial og box displays .
Sun Sto rEdge Net work 2 G b FC Ser ies Switc hes Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 283 V ERSION 1.0, M ARCH 2003 For the QLogic SANbox2- 64, the following displays.
Sun St orEdge N etwork 2 Gb FC S eries S witche s Zone Con figuratio n P AGE 28 4 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 3.
Sun Sto rEdge Net work 2 G b FC Ser ies Switc hes Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 285 V ERSION 1.0, M ARCH 2003 For the QLogic SANbox2- 64, the following displays: QLogic CLI NOTE: Use the CLI commands when the QLogi c SANbox Manag er GUI is not ava ilable.
Sun St orEdge N etwork 2 Gb FC S eries S witche s Zone Con figuratio n P AGE 28 6 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Zone T y pes All zone members must be specified by a w orld wide port name (WWPN) in orde r to comply with Fibre Channe l st andards.
Sun Sto rEdge Net work 2 G b FC Ser ies Switc hes Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 287 V ERSION 1.0, M ARCH 2003 3. The Edit Zoning — SANbox Manager dialog box displays. Conf irm that all zone memb ers are list ed as WWN.
Sun St orEdge N etwork 2 Gb FC S eries S witche s Zone Con figuratio n P AGE 28 8 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 QLogic SANbox Manager GUI 1. S tart the SANbox Manager applicat ion. The SANbox Manager — Faceplate dial og box displays .
Sun Sto rEdge Net work 2 G b FC Ser ies Switc hes Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 289 V ERSION 1.0, M ARCH 2003 For the QLogic SANbox2- 64, the following displays.
Sun St orEdge N etwork 2 Gb FC S eries S witche s Zone Con figuratio n P AGE 29 0 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 3. The Edit Zoning — SANbox Manager dialog box displays. Conf irm that all zone memb ers are list ed as WWN.
Sun Sto rEdge Net work 2 G b FC Ser ies Switc hes Zone Configu ration QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 291 V ERSION 1.0, M ARCH 2003 For the QLogic SANbox2- 64, the following displays: QLogic CLI NOTE: Use the CLI commands when the QLogi c SANbox Manag er GUI is not ava ilable.
Sun St orEdge N etwork 2 Gb FC S eries S witche s Operating Mode Confi guration P AGE 29 2 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Operating Mod e Configur ation Not appli cable. Sun StorEdge Specific Configuration Not appli cable.
QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 293 V ERSION 1.0, M ARCH 2003 Glossary Activity LED A port LED that indicates when frames are entering or leaving the port. Alias A collection of obj ect s that can be zoned together . An alias is not a zone, and can not have a zone or another a lias as a member .
P AGE 29 4 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1. 0, M ARCH 20 03 Glossary E-Port Expansi on port. A switch port that connect s to another FC-SW-2 compliant switch. Exp ansion Port See E-Port. ExtCredit Allows fu ll spee d operation ov er dist ances greater than 10 kilometers.
QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 295 V ERSION 1.0, M ARCH 2003 Glossar y ISLSecurity ISLSecurit y determines which swi tches a port will est ablish a link wit h. Any: we will link wit h any s witch . Ours: we will only link to another QLogic swi tch.
P AGE 29 6 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1. 0, M ARCH 20 03 Glossary Private Lo op A loop of pri vate device s connect ed to a single swit ch port.
QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 297 V ERSION 1.0, M ARCH 2003 Glossar y WWNN Wo rld wide node name WWPN Wo rld wide port n ame Zone A set of port s or devices gro uped togethe r to contr ol the ex change of informati on. Zone Set A set of zones grouped togeth er .
P AGE 29 8 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1. 0, M ARCH 20 03 Glossary.
QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 299 V ERSION 1.0, M ARCH 2003 Index B Brocade fab r ics, mer ging with QLogic fabrics 7 Brocade Silkworm 3200 and Silkworm 3800 switches Brocade speci.
P AGE 30 0 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Index D Domain ID c onfigurati on Brocade Silkworm 3200 and Silkworm 3800 switches 11 Brocade Sil kW orm 3900 an d S.
QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 301 V ERSION 1.0, M ARCH 2003 Index QLogic specific conf iguration 258 successful integrat ion checklist 259 switch a nd firmware versions 222 timeout.
P AGE 30 2 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Index Cisco MDS 9000 series switches 118 Cisco SN 542 8 storage r outer 91 IBM eServer BladeCent er Fibre Channel Sw.
QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 303 V ERSION 1.0, M ARCH 2003 Index INRANGE FC/9000 switch 161 McDA T A Intrepid 6000 se ries directors 240 McDA T A S phereon 4500 switc h 201 Sun S .
P AGE 30 4 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3 Index.
QL OGIC S WI TCH I NTERO PERABILI TY G UIDE P AGE 305 V ERSION 1.0, M ARCH 2003 Cont acting Q Logic For more i nformation about QLogic mark ets and appli cations, sales channels, pr oducts , milestones and technology roadmap s, please visi t the QLogic Web sit e at www .
Contactin g QLog ic P AGE 30 6 QL OGI C S WITCH I NT EROPERA B ILIT Y G UIDE V ERSION 1.0, M ARCH 200 3.
.
Switch Interoperability WWW.QLOGIC.COM SAN QLOGIC PRESS QLOGIC PRESS SN0135524-00 Rev A 3/03 THE ONLY SOURCE FOR MULTI-VENDOR INTEROPERABILITY v 1 3/2003 Switch Interoperability 3 / 03 v1 GUIDE SANbox ™ Guide QLogic solutions i n c lude industr y-leading controller chips, host bus adapters, network switches and management software.
デバイスQ-Logic SN0135524-00の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Q-Logic SN0135524-00をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはQ-Logic SN0135524-00の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Q-Logic SN0135524-00の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Q-Logic SN0135524-00で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Q-Logic SN0135524-00を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はQ-Logic SN0135524-00の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Q-Logic SN0135524-00に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちQ-Logic SN0135524-00デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。