www .quadra fi re.com January 3, 2007 7009-1 13E Quartet Front Solitaire Front TO P A Z DIRECT VENT ROOM HEA TER Owner ’ s Manual Installation and Operation Model: 839-1290 839-1320 839-1340 844-4120 R T ested and List ed by Beaverton Oregon USA OMNI- T est Laborat ories, Inc.
Page 2 Quadra-Fire · T opaz · 7009-1 13E January 3, 2007 Hearth & Home T echnologies welcomes you to our tradition of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality , durability , and performance.
Page 3 Quadra-Fire · T opaz · 7009-1 13E - T ABLE OF CONTENTS - January 3, 2007 Section 1: Listing and Code Approvals A. Appliance Certi fi cations ...................... 4 B. Glass Speci fi cations ............................ 4 C. BTU Speci fi cations .
Page 4 January 3, 2007 Quadra-Fire · T opaz · 7009-1 13E 1 Listing and Code Approvals The product is listed to ANSI standards for “V ented Gas Appliance Heaters” and applicable sections of “Gas Burning Heating Appliances for Manufactured Homes and Recre- ational V ehicles” and "Gas Fired Appliances for use at High Altitudes".
January 3, 2007 Page 5 Quadra-Fire · T opaz · 7009-1 13E NOTE: The following requirements reference various Massachusetts and national codes not contained in this document.
Page 6 January 3, 2007 Quadra-Fire · T opaz · 7009-1 13E 2 Getting Started Check building codes prior to installation. • Installation MUST comply with local, regional, state and national codes and regulations.
January 3, 2007 Page 7 Quadra-Fire · T opaz · 7009-1 13E 3 Appliance Location and Clearances A. Selecting Appliance Location NOTE: · Illustrations re fl ect typical installations and are FOR DESIGN PURPOSES ONL Y . · Illustrations/diagrams are not drawn to scale.
Page 8 January 3, 2007 Quadra-Fire · T opaz · 7009-1 13E 4 T ermination Locations A. V ent T ermination Minimum Clearances 24 in. (610mm) (minimum) to Perpendicular W all (Gas Only) A 18 in. (457mm) Gas or Wood T ermination Gas T ermination Gas T ermination A 6 in.
January 3, 2007 Page 9 Quadra-Fire · T opaz · 7009-1 13E Figure 4.4 V = VENT TERMINAL X = AIR SUPPL Y INLET = AREA WHERE TERMINAL IS NOT PERMITTED A = 12 inche s ............. clearances above grade , veran- da, porch, deck or balcony B = 1 2 in c hes .
Page 10 January 3, 2007 Quadra-Fire · T opaz · 7009-1 13E 5 V ent Information A. V enting Components B. Use of Elbows In order to comply with applicable codes and product warranties, use only follow.
January 3, 2007 Page 1 1 Quadra-Fire · T opaz · 7009-1 13E D. How to Use the V ent Graph E. V enting Guidelines 1. Measure the vertical distance from the center line of the flue pipe to the center of the 90° elbow .
Page 12 January 3, 2007 Quadra-Fire · T opaz · 7009-1 13E Female Locking Lugs Male Locking Lugs Step 1. Determine the desired location of the appliance. Check to ensure that wall studs or roof rafters are not in the way when the venting system is attached.
January 3, 2007 Page 13 Quadra-Fire · T opaz · 7009-1 13E Figure 5.5 When installing the Sapphire in a rear vent configuration with no vertical rise: a Snorkel Kit must be used, and a derating orifice must be installed. The appropriate orifice is supplied with the Rear V ent Kit .
Page 14 January 3, 2007 Quadra-Fire · T opaz · 7009-1 13E Step 5. Place the wall thimble cover over the pipe assembly and slide the appliance and vent assembly towards the wall, carefully inserting the vent pipe into the vent termination cap assembly .
January 3, 2007 Page 15 Quadra-Fire · T opaz · 7009-1 13E Step 1. Check the installation instructions for required 1 in. (25mm) clearances (air space) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafters, or other nearby combustible surfaces.
Page 16 January 3, 2007 Quadra-Fire · T opaz · 7009-1 13E Step 4. Assemble the desired lengths of pipe and elbows necessary to reach from the appliance up through the round support box. Ensure that all pipe and elbow connections are in their fully twist-locked position.
January 3, 2007 Page 17 Quadra-Fire · T opaz · 7009-1 13E MIN. 1 in. (25mm) CLEARANCE CEILING FIRES T OP NAILS MIN. 1 in. (25mm) CLEARANCE MIN. 1 in.
Page 18 January 3, 2007 Quadra-Fire · T opaz · 7009-1 13E 2. Cathedral Ceiling LEVEL CA THEDRAL CEILING SUPPORT BOX 2 in. (51mm) MIN. BELOW FINISHED CEILING CUT HOLE 1/8 in. (3mm) GREA TER IN SIZE THAN P A TTERN OF SUPPOR T BOX AS IT IS PROJECTED ONTO ROOF LINE Figure 5.
January 3, 2007 Page 19 Quadra-Fire · T opaz · 7009-1 13E 3. Class A Metal Chimney Figure 5.20 HIGH WIND TERMINA TION CAP SHEET MET AL SCREWS DRILL FOUR 1/8 in. (3mm) DIAMETER HOLES Figure 5.22 Figure 5.23 Step 4. Pass the flex pipe down through the center of the chimney system, and center the top adapter on the top of the chimney pipe.
Page 20 January 3, 2007 Quadra-Fire · T opaz · 7009-1 13E 4. Existing Masonry Chimney T ype A - Up & Out Installations for T op V ent Configurations Figure 5.24 T ype B - Hearth Rear V ent Installations for Use With Rear V ent Kit (see Section 12 for conversion kit and venting components.
January 3, 2007 Page 21 Quadra-Fire · T opaz · 7009-1 13E 10 in. x 10 in. (254mm x 254mm) FRAMED OPENING IN W ALL STUDW ALL MASONR Y CHIMNEY RETRO CONNECTOR FOUR MASONR Y BOL TS (NOT INCLUDED) W ALL THIMBLE COVER CUT AND BEND FLASHING AS NEEDED TO FIT CHIMNEY SEALANT -ADHESIVE Figure 5.
Page 22 January 3, 2007 Quadra-Fire · T opaz · 7009-1 13E HIGH WIND TERMINA TION CAP TOP ADAPTER THREE SHEET MET AL SCREWS FLASHING Step 9. Attach the flex to the retro connector. Use three sheet metal screws to attach the flex liner to the connector ( Figure 5.
January 3, 2007 Page 23 Quadra-Fire · T opaz · 7009-1 13E 6 Gas Information A. Fuel Conversions Before making gas connections ensure that the appliance being installed is compatible with the available gas type.
Page 24 January 3, 2007 Quadra-Fire · T opaz · 7009-1 13E A B C Figure 6.8 T urn control knob to the OFF position, ensure that gas supply to the valve has been turned off. Using a T orx TH20, or slotted screwdriver , remove the three pressure reg- ulator mounting screws (A) , pressure regulator tower (B) , and diaphragm (C) .
January 3, 2007 Page 25 Quadra-Fire · T opaz · 7009-1 13E Fire Risk. Explosion Risk. • If the information in these instructions is not followed exactly , a fi re, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life.
Page 26 January 3, 2007 Quadra-Fire · T opaz · 7009-1 13E • A small amount of air will be in the gas supply lines. When fi rst lighting appliance it will take a short time for air to purge from lines. When purging is complete the appliance will light and operate normally .
January 3, 2007 Page 27 Quadra-Fire · T opaz · 7009-1 13E 7 Electrical Information A. Recommendation for Wire C. Standing Pilot Ignition System Wiring See B5 below for recommended maximum lead length (two wire) when using wall thermostat/switch. B. Connecting to the Appliance This appliance DOES NOT require 1 10 V AC supply for operation.
Page 28 January 3, 2007 Quadra-Fire · T opaz · 7009-1 13E Figure 7.1 CAUTION Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. V erify proper operation after servicing. Shock hazard.
January 3, 2007 Page 29 Quadra-Fire · T opaz · 7009-1 13E 8 Appliance Setup A. Remove Shipping Materials Remove shipping materials from inside or underneath the fi rebox. B. T op to Rear V ent Conversion Figure 8.1 Remove top trivet, if installed. Remove vent pipe adapter and gasket.
Page 30 January 3, 2007 Quadra-Fire · T opaz · 7009-1 13E D. Accessories Install approved accessories per instructions included with accessories. Refer to Section 12 for appropriate accesso- ries. Shock or fi re risk. Use ONL Y optional accessories approved for this appliance.
January 3, 2007 Page 31 Quadra-Fire · T opaz · 7009-1 13E E. Front Installation Fronts shipped attached to face Figure 8.12 T o remove the face, loosen the thumb bolt beneath the ashlip. Figure 8.13 Lift up on the top of the Front, gently pulling out on the bottom.
Page 32 January 3, 2007 Quadra-Fire · T opaz · 7009-1 13E NOTE: Side brick panels will fit only if installed at an angle. Do not attempt to push the brick flat against the outer wall of the firebox. Brick should rest against spacer on inside of firebox.
January 3, 2007 Page 33 Quadra-Fire · T opaz · 7009-1 13E Figure 8.20 Insert locator pin into right front log. Insert rear log onto log pan over stud. Figure 8.22 Insert locator pin into right front log. Place right front log on burner in the grooves provided on the burner surface.
Page 34 January 3, 2007 Quadra-Fire · T opaz · 7009-1 13E NOTE: This blower utilizes a snap disc to control ON and OFF operation. When the correct temperature is reached, the blower will automatically turn ON. Use the rheostat knob to adjust the fan to High or Low to suit your preferences.
January 3, 2007 Page 35 Quadra-Fire · T opaz · 7009-1 13E SNAP DISC 6 in. (152mm) BLACK BLOWER 4 in. (102mm) WHITE CORD M F M F 34 in. (864mm) BLACK 34 in.
Page 36 January 3, 2007 Quadra-Fire · T opaz · 7009-1 13E See Vent Graph for Recommendations on page 1 1 before you begin your adjustment. If your installation falls within the range of the gray shaded area of graph, it may be necessary to make an adjustment to the vertical damper to improve the flame appearance in your appliance.
January 3, 2007 Page 37 Quadra-Fire · T opaz · 7009-1 13E 9 Operating Instructions A. Before Lighting Appliance Read this entire manual prior to using the appliance. Failure to follow the instructions may result in property damage, bodily injury, or even death.
Page 38 January 3, 2007 Quadra-Fire · T opaz · 7009-1 13E C. Lighting Appliance 1. Set the thermostat to lowest setting. 2. T urn off all electric power to the appliance if service is to be performed. 3. Push in gas control knob slightly and turn clockwise to "OFF" position.
January 3, 2007 Page 39 Quadra-Fire · T opaz · 7009-1 13E D. After Appliance is Lit When you light your appliance, you may notice that it pro- duces heat which does have an associated odor or smell.
Page 40 January 3, 2007 Quadra-Fire · T opaz · 7009-1 13E 10 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service.
January 3, 2007 Page 41 Quadra-Fire · T opaz · 7009-1 13E Symptom Possible Cause Corrective Action 3. (Continued) c. Defective valve. T urn the valve knob to the ON position. Place the ON/OFF switch in the ON position. Check the millivolt meter at the thermopile terminals.
Page 42 January 3, 2007 Quadra-Fire · T opaz · 7009-1 13E 11 Maintaining and Servicing Y our Appliance Although the frequency of your appliance servicing and maintenance will depend on use and the type of installation, a quali fi ed service technician should perform an appliance check-up at the beginning of each heating season.
January 3, 2007 Page 43 Quadra-Fire · T opaz · 7009-1 13E Inspect Maintenance T asks Doors 1. Inspect for scratches, dents or other damage and repair as necessary . 2. V erify no obstructions to air fl ow . 3. V erify maintenance of proper clearance to combustible household objects.
Page 44 January 3, 2007 Quadra-Fire · T opaz · 7009-1 13E 12 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions.
January 3, 2007 Page 45 Quadra-Fire · T opaz · 7009-1 13E B. V ent Components Diagram Figure 12.2 SL-D Series V ent Components 4 in. (102 mm) inner pipe 6-5/8 in. (168 mm) outer pipe 9-1/4 in. (235mm) 6-1/2 in. (165mm) 6-5/8 in. (168mm) 17-24 in. (432-610mm) 1 1-3/4 in .
Page 46 January 3, 2007 Quadra-Fire · T opaz · 7009-1 13E C. V ent Components List COMPONENTS 930D Ceiling Support / W all Thimble, Black 941 Cathedral Ceiling Support, Black 942 W all Thimble 908B .
January 3, 2007 Page 47 Quadra-Fire · T opaz · 7009-1 13E D. Service Parts List R TO P A Z (NG, LP) Exploded Parts Diagram Beginning Manufacturing Date: 12-8-03 Ending Manufacturing Date: Item # Des.
Page 48 January 3, 2007 Quadra-Fire · T opaz · 7009-1 13E IMPORT ANT : THIS IS DA TED INFORMA TION. The most current information is located on your dealer's VIP site. When ordering, supply serial and model numbers to ensure correct service parts.
January 3, 2007 Page 49 Quadra-Fire · T opaz · 7009-1 13E IMPORT ANT : THIS IS DA TED INFORMA TION. The most current information is located on your dealer's VIP site. When ordering, supply serial and model numbers to ensure correct service parts.
Page 50 January 3, 2007 Quadra-Fire · T opaz · 7009-1 13E Ori fi ce, Pilot, NG, EZ, #62 842-4440 Paint, T ouch-up, Matte Black 7000-304 Paint, T ouch-up, Porcelain Mahogany 855-1450 Paint, T ouch-u.
January 3, 2007 Page 51 Quadra-Fire · T opaz · 7009-1 13E Part Description Alphabetical Order Part # Blower Assembly with Speed Control (Rheostat) BK-GAS Decorative Glass Accent for Solitaire Front,.
Page 52 January 3, 2007 Quadra-Fire · T opaz · 7009-1 13E F . W arranty Policy Lifetime Warranty R LIMITED LIFETIME W ARRANTY The Hearth & Home T echnologies limited Lifetime Warranty guarantees that the following components will work as designed for the lifetime of the stove or Hearth & Home T echnologies will repair or replace them.
January 3, 2007 Page 53 Quadra-Fire · T opaz · 7009-1 13E THIS P AGE INTENTIONALL Y LEFT BLANK..
Page 54 January 3, 2007 Quadra-Fire · T opaz · 7009-1 13E THIS P AGE INTENTIONALL Y LEFT BLANK..
January 3, 2007 Page 55 Quadra-Fire · T opaz · 7009-1 13E THIS P AGE INTENTIONALL Y LEFT BLANK..
Page 56 Quadra-Fire · T opaz · 7009-1 13E January 3, 2007 Hearth & Home T echnologies 1445 North Highway Colville, W A 991 14 Division of HHT INDUSTRIES CONT ACT INFORMA TION : DEALERSHIP WHERE .
デバイスQuadra-Fire 839-1290の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Quadra-Fire 839-1290をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはQuadra-Fire 839-1290の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Quadra-Fire 839-1290の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Quadra-Fire 839-1290で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Quadra-Fire 839-1290を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はQuadra-Fire 839-1290の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Quadra-Fire 839-1290に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちQuadra-Fire 839-1290デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。