QTM300CA USER'S GUIDE Cloning Adapter for the QT3xx family of QProx™ ICs The QTM300CA is a cloning adapter designed to interface between any QT3xx 8-pin sensor IC (QT300, QT310, QT320) and a PC or other host device. This adapter permits the designer to upload settings from a PC into the target chip or to read the settings inside a chip.
To begin using the board right away 1. Connect the QTM300CA to a PC using the serial cable (included). Make sure the serial port is not being used by any other application or driver. 2. Connect the QTM300CA to the target board’s 10-pin IDC cloning header; the stripe of the cable connects to the pin marked with a white square .
Figure 1 - Board Layout If a QT3xx chip has been auto-detected, this button will clone Setups data from the QTM300CA to the chip. The ‘PROG’ LED (see next section) indicates the programming result. The QTM300CA can store three sources of data, one for each part type.
Indicates the programming status of the target chip in Stand-alone mode. The PROG LED will light during the cloning process in Stand-alone mode. Afterwards the LED will flash on/off 3 times to indicate completion: Fast flashing: (0.1s between flashes) the clone process was a success.
Figure 2 - QT3View Screen Restores a config file saved by (File | Save). All three part selector configurations (tabs) will be restored by this action. Saves all three part selector configurations to disk in a single file, to a file name of your choice.
The status bar at the bottom shows the serial port and connection status. Possibilities are: Serial Port Status: - Off Line - COM1: 57600 N 8 1 - COM2: 57600 N 8 1 Connection Status: - Status: Clone c.
Cloning Directly to a Chip You can read and clone back information to a QT3xx chip directly from your PC without involving the onboard stand-alone memory of the QTM300CA. Here’s how.... Refer to the device data sheet and the QT3View help file for more information on Setup issues.
Clone the Setups to the Chip: Push the PROG button on the board. The PROG LED will light to indicate programming status. The PROG LED will flash to indicate the programming result; see page 4. Step 2 Hook everything up: Connect the QTM300CA’s cloning cable to the target PCB, or insert a QT3xx chip into the onboard socket.
If the Synchronization input is used, a 10K resistor should be used to avoid problems with the cloning process; see Figure 4 below. QT310 Place the connector as close as possible to the chip.
Figure 5 - QT320 Clone Connections VSS 8 S2A S1A 2 6 3 C S2B S1B 5 C SCK OUT2 7 OUT2 S2 OUT1 4 OUT1 1 VDD Vdd S1 SDO SDI GND Electrode 2 Electrode 1 l q 10 QTM300CA/R1.
Table 1 - Clone Cable Functional Pinout - Usage by Part N/C N/C N/C 10 SCK SCK SCK 9 Vcc 1 Vcc 1 Vcc 1 8 SDI SDI SDI / REQ 7 SDO SDO SDO 6 N/C N/C N/C 5 N/C N/C N/C 4 N/C N/C DRDY 3 GND GND GND 2 Vcc 1 Vcc 1 Vcc 1 1 QT320 QT310 QT300 Pin Note 1: Vcc is connected via a 1K pullup on QTM300CA board Table 2- Chip ZIF Socket Order Information www.
l Q Copyright © 2003 QRG Ltd. All rights reserved. Patented and patents pending Corporate Headquarters 1 Mitchell Point Ensign Way, Hamble SO31 4RF Great Britain Tel: +44 (0)23 8056 5600 Fax: +44 (0)23 8045 3939 admin@qprox.com www.qprox.com North America 651 Holiday Drive Bldg.
デバイスQuantum QTM300CAの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Quantum QTM300CAをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはQuantum QTM300CAの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Quantum QTM300CAの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Quantum QTM300CAで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Quantum QTM300CAを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はQuantum QTM300CAの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Quantum QTM300CAに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちQuantum QTM300CAデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。