RayburnメーカーCookmaster 200SFWの使用説明書/サービス説明書
ページ先へ移動 of 8
Inst allation Instructions for Rayburn Cookmaster 200SFW and Rayburn Cookmaster Plus 212SFW Solid Fuel Cooker REMEMBER, when replacing a part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require.
The cooker fully meets the requirements of BS: 1252 and is fully approved by the HETAS Ltd Approval Scheme. Air for combustion within the firebox and the rate of burning is determined by the manually operated spinwheel control on the ashpit door and flue damper.
IMPORTANT : LIFT OUT THE HOTPLATE AND CEMENT SEAL THE JOINT BETWEEN THE BOILER FACE AND ITS LOCATING FACE ON THE FIREBOX SIDES WITH FIRE CEMENT. RENEW ANY BRICKWORK CEMENTED JOINTS THAT MAY HAVE OPENED IN TRANSIT.
The minimum chimney draught requirement for the 200SFW at nominal total heat output is 2.5 Pa. The minimum chimney draught requirement for the 212SFW at nominal total heat output is 12 Pa. The mean flue gas temperature of the Rayburn 200SFW directly downstream of the flue spigot at nominal heat output is 131ºC.
IN ALL TYPE OF CHIMNEYS THE MINIMUM HEIGHT FOR CORRECT OPERATION OF THE CHIMNEY IS 4.5m AND SHOULD TERMINATE ABOVE THE ROOF IN ACCORDANCE WITH REGIONAL STATUTORY REQUIREMENTS RECOMMENDED FLUE DRAUGHT - 12 pa MINIMUM.
Tall chimneys may develop excessively high updraughts which prevent the appliance operating correctly. It is recommended that a proprietary brand adjustable flue draught stabiliser having an openable .
After completing the installation, the Heating Contractor should demonstrate to the user, the operation of the appliance and the routine flue operating method. 1. Check that the system is full of water and free from air pockets. (Rayburn Cookmaster Plus 212SFW only).
8 For further advice or information contact your local distributor/stockist With Aga’s policy of continuous product improvement, the Company reserves the right to change specifications and make modifications to the appliance described at any time. Manufactured by Aga Station Road Ketley Telford Shropshire TF1 5AQ England www.
デバイスRayburn Cookmaster 200SFWの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Rayburn Cookmaster 200SFWをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRayburn Cookmaster 200SFWの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Rayburn Cookmaster 200SFWの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Rayburn Cookmaster 200SFWで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Rayburn Cookmaster 200SFWを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRayburn Cookmaster 200SFWの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Rayburn Cookmaster 200SFWに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRayburn Cookmaster 200SFWデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。