RAYPAK REPLACEMENT INSTRUCTIONS IMPORTANT NOTICE These instructions are intended primar ily for use by qua lified personnel s pecif ical ly trained and experi enced in the insta llati on of this type of heating equipment and related system components.
r r Fig. 1 REMOVE THESE SCREWS Fig. 2 Page 2 2151 Eastman Ave., Oxnar d, CA 93030 805-278-5300 Fax 800-777-7026 www.raypak.c om Technical suppor t is availa ble M-F, 5:30 A M to 5 :00 PM PS T, at 800- 947-2975 or 800- 627-2975 REMOVE THESE SCREWS ACCESSING THE BOARD - MODELS 206A, 207A, 266A, 267A, 336A, 337A, 406A, 407A: 1.
REMOVING THE CIR CUIT BOARD - MODELS 185A/B, 265A/B, 33 5A/B, 405A/B: Make sure the power and gas are off. 1. Unplug all connectors from old circuit board. Fig. 7 . 2. Unplug keypad ribbon from old circuit board. 3. Remove four screws as shown in Fig.
2151 Eastman Ave., Oxnar d, CA 93030 805-278-5300 Fax 800-777-7026 www.raypak.c om Technical suppor t is availa ble M-F, 5:30 A M to 5 :00 PM PS T, at 800- 947-2975 or 800- 627-2975 Page 4 UNPLUG ALL CONNECTORS REMOVE MOUNTING S CREWS Fig.
Page 5 DISCONNECTING IGNITI ON CONTROL - M ODEL S 185A, 265A, 33 5A, AND 405A ONLY : Make sure the power and gas are off. 1. Unplug all wires and connect ors from i gnition control. (See Fig. 11 .) Note: The ignition control is now part of the new control circuit b oard.
Page 6 PROPANE HEATERS ONLY: Make sure the power and gas are off. 1. Locate the pr opane tab on the board as shown in Fig. 12 . 2. Break off tab with pliers as shown in Fig. 13 & Fig. 14 . Fig. 12 Fig. 14 PROPANE BROKEN TAB 2151 Eastman Ave., Oxnar d, CA 93030 805-278-5300 Fax 800-777-7026 www.
MODELS 185, 265, 335 & 405, A & B SERIES, LOW NOX ONLY: Make sure the power and gas are off. 1. DO NOT break tab See Fig. 15 and Fig.16. 2. No additional wiring or connecti ons are necessary. 2151 Eastman Ave., Oxnar d, CA 93030 805-278-5300 Fax 800-777-7026 www.
LOW NOX MODELS 207A, 267A, 337A & 407A: Make sure the power and gas are off. 1. Locate Lo Nox tab and P-10 air switch termin al on the board as shown i n Fig. 17 and Fig. 18 . 2. Break off tab shown in Fig. 19 with pliers. 3. Attach the wire from the air s witch to the P-10 locati on shown in Fig.
Page 9 NEW CIRCUIT BOARD & GASKET INSTALLATION USING OLD BEZE L - M ODEL S 185, 265, 335 & 405, A & B SERIES: Make sure the power and gas are off. Note: Disregard window gasket installation i f already present. LA Y B OA RD DOWN Fig. 22 CLEAR WINDOW GASKET STICKY SIDE TO PLASTIC BEZEL RE-ASSEMBLE WITH NEW BOAR D MOUNTING SCREWS Fig.
GASKET & NEW CIRCUIT BO ARD NEW BEZEL INSTALLATION - MODELS 206A, 207A, 266A, 267A, 336A, 337A, 406A, 407A: Make sure the power and gas are off. Note: Disregard window gasket installation i f already present. 1. Remove backing on gasket and install a dhesive side on the control panel bezel as shown in Fig.
Page 11 REMOVING & REPLACING SENSOR - MODELS 185, 265, 335 & 405, A & B SERIES: Make sure the power and gas are off. 1. Loosen drain plug to relieve pressure i n heat exchanger. See Fig. 27 . 2. Remove five screws and in/out access panel as shown in Fig.
Page 12 Fig. 33 Fig. 32 CLEAR PLASTIC STRIP WITH THIN CONNECTOR Fig. 34 PLASTIC SHIELD & BRACKET INSTAL LATION - MODELS 185, 265, 335 & 405, A & B SERIES: Make sure the power and gas are off. 1. Note that the plastic shie ld is installed under the front bracket as pictured.
Ensure the power and the gas has been shut off. 1. Re-connect pilot wire (side B) to new board. See Fig. 35. CONNECT THIS END TO NEW PC BOARD SPARK LUG CONNECT THIS END TO EXISTING PILOT WIRE Fig. 37 EXISTING PILOT WIRE Page 13 P/N 241169 Rev.-3 2151 Eastman Ave.
Page 14 2151 Eastman Ave., Oxnar d, CA 93030 805-278-5300 Fax 800-777-7026 www.raypak.c om Technical suppor t is availa ble M-F, 5:30 A M to 5 :00 PM PS T, at 800- 947-2975 or 800- 627-2975 P/N 241169 Rev.
Page 15 2151 Eastman Ave., Oxnar d, CA 93030 805-278-5300 Fax 800-777-7026 www.raypak.c om Technical suppor t is availa ble M-F, 5:30 A M to 5 :00 PM PS T, at 800- 947-2975 or 800- 627-2975 P/N 241169 Rev.
Page 16 2151 Eastman Ave., Oxnar d, CA 93030 805-278-5300 Fax 800-777-7026 www.raypak.c om Technical suppor t is availa ble M-F, 5:30 A M to 5 :00 PM PS T, at 800- 947-2975 or 800- 627-2975 P/N 241169 Rev.
Page 17 2151 Eastman Ave., Oxnar d, CA 93030 805-278-5300 Fax 800-777-7026 www.raypak.c om Technical suppor t is availa ble M-F, 5:30 A M to 5 :00 PM PS T, at 800- 947-2975 or 800- 627-2975 P/N 241169 Rev.
Page 18 2151 Eastman Ave., Oxnar d, CA 93030 805-278-5300 Fax 800-777-7026 www.raypak.c om Technical suppor t is availa ble M-F, 5:30 A M to 5 :00 PM PS T, at 800- 947-2975 or 800- 627-2975 P/N 241169 Rev.
デバイスRaypak 185Aの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Raypak 185Aをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRaypak 185Aの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Raypak 185Aの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Raypak 185Aで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Raypak 185Aを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRaypak 185Aの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Raypak 185Aに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRaypak 185Aデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。