Raypak ® Swimming Pool Heat Pump OWNER’S MANUAL This manual should be maint ained in legible condition and kep t adjacent to the heat pump or in a safe p lace for future use. For additional information call: (800) 260-2758 Manual Effective Da te: 1 1/15/2004 De ve lop ed an d p ri nt ed i n U .
i PRODUCT SAFETY SIGNS AND LABE LS This manual, as well as the pool/spa heat pum p itself, contains ANSI-approved product safety signs and labels. Please read these signs and labe ls, as they convey important safety information about hazards that may be potentially present in and around the heat pump.
ii Swimming Pool Heat Pump OWNER’S MANUAL - Models 5100 and 6100 CONTENTS Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 I. Installation Considerations . . . .
1 Intr oduction This pool heat pump is an electromec hanical machine that incorporates a pressurized refrigerant gas in a sealed sys tem. ONL Y trained and qualified service personnel are authorized to install or service this eq uipment.
2 Situate the pool heat pump caref ully to minimize installati on costs while providing maximum efficiency of operation, and to allow adequate service access, as follows: • For unrestricted air intake and service access, pos ition each side of the un it at least 1 ft from walls, pipes and other obstructions.
3 III. W ater Connections The heat pump inlet and outlet connection s are NOT interchangeable. They must be connected as inst ructed below . 1. Connect the heat pump in the return water line between the filter and the pool. See page 10, Plumbing Diag rams.
4 NOTE: The heat pump will not run whe n the Remote position is selected and there is no remote co ntrol system attached. Defrost Switch : Prevents heat pump operation if am bient air temperature falls below a predetermined safe minimum (appr oximately 42-48° F , based on hum idity).
5 NOTE: The heat pump wi ll be OFF when the Remote position is selected on th e P ool/Sp a selector switch and there is no remote con trol system att ached. 4. Allow the heat pump to operate for a few minutes to stabilize operating pressure s and to allow various component temperatures to normalize.
6 VII. Fr eeze Protection If the heat pump is installed in a location subjec t to freezing conditions, it is important to protect the water circuit from fr eezing, just as should be done for the pump and filter . System Drain-Down 1. T urn the heat pump circuit break er or disconnect switch to OFF .
7 C. Unplug Condensation Drain Holes - The heat pump extracts humidity from the air as it passes through the coil, similar to the way a cold drink outside “sweats” on a hot day .
8 B. UNIT IS NOT RUNNING • Is the control panel Power lamp ON? If not, the cir cuit brea ker may be shut OFF or tripped. Reset the breaker by switching it OFF , then back ON. V erify that the br eaker is set and operating pr operly befor e calling for service.
9 Plumbing Diagrams For systems with p umps of less than 2 HP (under 80 gpm), no external bypass is required. Connections ar e 2-inch unio ns. Plumb the h eat pump after the filter and before any chlorinators.
10.
デバイスRaypak 6100の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Raypak 6100をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRaypak 6100の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Raypak 6100の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Raypak 6100で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Raypak 6100を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRaypak 6100の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Raypak 6100に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRaypak 6100デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。